Table 3-1  Airflow Direction
Fan type
Fan label
Direction
Forward fan
AIR OUTLET
Air flows from cable sockets to fans
Reverse fan
AIR INLET
Air flows from fans to cable sockets
Table 3-2  Temperature, Humidity, and Elevation Specifications
Description
Operating
U.S.
Metric
Nonoperating
U.S.
Metric
Temperature
59˚F to 89.6˚F
15˚C to 32˚C
-40 to 158°F
-40 to 70°C
Humidity
10-90% noncondensing
10-90% noncondensing
Relative humidity
20% to 80% noncondensing, 80˚F maximum wet bulb
20% to 80% noncondensing, 27˚C maximum wet bulb
5 to 95% noncondensing
5 to 95% noncondensing
Elevation
Maximum 10,006 feet at 77˚F 2,953 feet at 89.6˚F
Derate maximum ambient 1.8˚F per 984 feet above 2952 feet.
Maximum 3050 meters at 25˚C900 meters at 32˚CDerate maximum ambient 1˚C per 300 meters above 900 meters.
0 to 39370 feet
12000 meters
Table 3-3  Acoustic Noise Emission Declaration for Oracle Switch ES2-64
Description
With Inlet Fans
With Outlet Fans
Acoustic idle power (LWAd)
7.4 B
7.2 B
Acoustic operating power (LWAd)
7.4 B
7.2 B
Table 3-4  Acoustic Noise Emission Declaration for Oracle Switch ES2-72
Description
With Inlet Fans
With Outlet Fans
Acoustic idle power (LWAd)
7.5 B
7.5 B
Acoustic operating power (LWAd)
7.5 B
7.5 B