5.6 chg-ee-card

Parameters

Use this command to enter/modify Eagle Eyes Network card data in the Eagle Eyes Card (EE CARD) table. The EE CARD entry consists of Card location and Eagle Eyes specific data.

loc (mandatory)
Eagle Eyes Card location.
Range:
1101 - 1108, 1111 - 1112, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118
action (optional)
Action to be performed on the specified filter ID for the card.
Range:
attach
detach
Default:
No change to the current value.
System Default:
0
fltid (optional)
A comma-separated Eagle Eyes Filter ID list to be associated or disassociated with the card. Up to 8 FLT IDs can be specified in the list.
Range:
1-200
Default:
No change to the current value.
System Default:
0
kblim (optional)
Sets the file size limit of the capture file created, in kilobytes.
Range:
1-4000000
Default:
No change to the current value.
System Default:
none
pktlim (optional)
Sets the limit on the number of Ethernet frames to send.
Range:
1-10000000
none
Default:
No change to the current value.
System Default:
none
seclim (optional)
Sets the limit on the amount of time to perform the trace, in seconds.
Range:
1-5644800
none
Default:
No change to the current value.
System Default:
none
thr (optional)
Sets the sending rate of the Eagle Eyes throttle task in IMT packets per second. The packets will not be captured unless this parameter is set to a non-zero value for the particular card.
Range:
1000--10000
Default:
No change to the current value.
System Default:
0

Example

chg-ee-card:loc=1101:fltid=12:action=attach:thr=2000:pktlim=5000

chg-ee-card:loc=1102:kblim=40000:seclim=3000000

chg-ee-card:loc=1101:fltid=13:action=detach:pktlim=none

Dependencies

If the fltid parameter is specified, then the action parameter must be specified.

2379 E2379 Cmd Rej: Missing parameter

The EE CARD table cannot contain more than 256 entries.

2862 E2862 Cmd Rej: EE Card table is full

The EE CARD table must be accessible.

2867 E2867 Cmd Rej: Unable to read EE Card table

At least one optional parameter must be specified.

2136 E2136 Cmd Rej: At least one optional parameter is required

The fltid specified should not be already associated with the card.

2889 E2889 Cmd Rej: Duplicate filter on card is not allowed.

The value specified for the fltid parameter must already exist in the EE FLT table.

2827 E2827 Cmd Rej: Filter not present

Maximum of 16 include filters can be attached to a card.

2970 E2970 Cmd Rej: Max limit of INC/EXC Filters reached on card

Maximum of 16 exclude filters can be attached to a card.

2970 E2970 Cmd Rej: Max limit of INC/EXC Filters reached on card.

The value specified for the loc parameter must not be a system reserved location.

2154 E2154 Cmd Rej: Card slot reserved by system

The IMT table must be accessible.

2102 E2102 Cmd Rej: Failed reading the IMT table

The card in the location specified by the loc parameter must have Eagle Eyes service capability.

2144 E2144: Location invalid for hardware configuration

The card loc specified to detach a filter must have Eagle Eyes configured.

4916 E4916 Command invalid for hardware configuration

The card at the specified location must be equipped.

2101 E2101 Cmd Rej: Card location is unequipped

The Filter appl and card appl should be same.

2812 E2812 Cmd Rej: EE Filter does not match card appl type

Notes

The value specified for the loc parameter must refer to a card running one of the following GPLs, and the referenced card must be equipped:
  • IPSG, IPLHC, IPGHC
  • ATMHC
  • SS7HC
  • SIPHC
  • DEIRHC

Output

chg-ee-card:loc=1101:fltid=12:action=attach:thr=2000:pktlim=5000

    tekelecstp 10-03-08 14:43:31 EST  EAGLE 46.0.0

    EE CARD table is (2 of 256) 1% full

    CHG-EE-CARD: MASP A - COMPLTD