5.6 chg-ee-card
Parameters
Use this command to enter/modify Eagle Eyes Network card data in the Eagle Eyes Card (EE CARD) table. The EE CARD entry consists of Card location and Eagle Eyes specific data.
- loc (mandatory)
- Eagle Eyes Card location.
- Range:
- 1101 - 1108, 1111 - 1112, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118
- fltid (optional)
- A comma-separated Eagle Eyes Filter ID list to be associated or disassociated with the card. Up to 8 FLT IDs can be specified in the list.
Example
chg-ee-card:loc=1101:fltid=12:action=attach:thr=2000:pktlim=5000
chg-ee-card:loc=1102:kblim=40000:seclim=3000000
chg-ee-card:loc=1101:fltid=13:action=detach:pktlim=none
Dependencies
If the fltid parameter is specified, then the action parameter must be specified.
2379 E2379 Cmd Rej: Missing parameter
The EE CARD table cannot contain more than 256 entries.
2862 E2862 Cmd Rej: EE Card table is full
The EE CARD table must be accessible.
2867 E2867 Cmd Rej: Unable to read EE Card table
At least one optional parameter must be specified.
2136 E2136 Cmd Rej: At least one optional parameter is required
The fltid specified should not be already associated with the card.
2889 E2889 Cmd Rej: Duplicate filter on card is not allowed.
The value specified for the fltid parameter must already exist in the EE FLT table.
2827 E2827 Cmd Rej: Filter not present
Maximum of 16 include filters can be attached to a card.
2970 E2970 Cmd Rej: Max limit of INC/EXC Filters reached on card
Maximum of 16 exclude filters can be attached to a card.
2970 E2970 Cmd Rej: Max limit of INC/EXC Filters reached on card.
The value specified for the loc parameter must not be a system reserved location.
2154 E2154 Cmd Rej: Card slot reserved by system
The IMT table must be accessible.
2102 E2102 Cmd Rej: Failed reading the IMT table
The card in the location specified by the loc parameter must have Eagle Eyes service capability.2144 E2144: Location invalid for hardware configuration
The card loc specified to detach a filter must have Eagle Eyes configured.
4916 E4916 Command invalid for hardware configuration
The card at the specified location must be equipped.
2101 E2101 Cmd Rej: Card location is unequipped
The Filter appl and card appl should be same.
2812 E2812 Cmd Rej: EE Filter does not match card appl type
Notes
- IPSG, IPLHC, IPGHC
- ATMHC
- SS7HC
- SIPHC
- DEIRHC
Output
chg-ee-card:loc=1101:fltid=12:action=attach:thr=2000:pktlim=5000
tekelecstp 10-03-08 14:43:31 EST EAGLE 46.0.0
EE CARD table is (2 of 256) 1% full
CHG-EE-CARD: MASP A - COMPLTD
Related Topics