Electrical Requirements
Oracle Server X7-8 uses AC power. The following table contains the power supply
specifications.
Note -
The power dissipation numbers listed in the following table are the maximum rated
power numbers for the power supply used in the system. The numbers are not a rating
of the actual power consumption of the system. For up-to-date information on power
consumption, go to the Oracle Power Calculators web site
http://www.oracle.com/us/products/servers-storage/sun-power-calculators/index.html, and click the Oracle Server X7-8 link.
|
|
Voltage (nominal)
|
200-240 VAC
|
Input current (maximum)
|
-
23A @ 200 to 240 VAC
-
12A max per cord
|
Frequency (nominal)
|
50/60 Hz
|
Maximum power consumption
|
-
Single 4-socket –1980 W
-
Dual 4-socket – 3950 W
-
Single 8-socket – 3880 W
|
Maximum heat output
|
13475 BTU/Hr
|
|
Your Oracle Server X7-8 can operate effectively over a range of voltages and
frequencies.
 | Caution -
The system must have a reliable power source. If the system exceeds the voltage
and frequency ranges, damage to the server might occur. Electrical disturbances,
such as the following, might damage the system:
-
Fluctuations caused by brownouts
-
Wide and rapid variations in input voltage levels or in input power
frequency
-
Electrical storms
-
Faults in the distribution system, such as defective wiring
|
To protect your server from disturbances, use a dedicated power
distribution system, power-conditioning equipment, and lightning arresters or power
cables to protect from electrical storms.
See the following sections for additional guidelines.