Completing the Quality / Inspection Subtab
To add an advanced manufacturing work bench test, complete the Quality / Inspection subtab.
To complete the quality / inspection subtab:
-
Click the Quality / Inspection subtab.
-
Click New AM Mfg Work Bench Tests.
-
In the AM Mfg Work Bench Tests form, in the Operation Task Inspection section, complete the following steps:
-
Select an Item from the list.
-
(Optional) Select a Test Name from the list.
NetSuite populates the Inspection Method, Inspection Type, and Inspection Results fields with the test’s details.
-
Select an Inspection Method from the list.
For example, Visual Count or Measurement.
-
Enter a Description of the test.
-
Enter the name of the Quality Management System Reference.
-
Enter the Operation Inspection Sequence number.
-
-
In the Measurements Standards and Attributes section, complete the following steps:
-
Select an Inspection Type from the list.
For example, Standard Result or Requires Sampling.
-
Select an Inspection Results measure from the list.
For example, Pass/Fail or Measurement.
-
Enter a Sample Size.
-
Select a Sample Frequency from the list.
For example, Each Unit, Each Batch, Each Lot, One Sample Per Run, Once Per Operation, or Every Hour.
-
Select an Evaluation Criteria from the list.
For example, Test Passes or Fails, Percentage of Sample Passes, Average of Sample Values in Tolerance, or Measurement Only.
-
Enter a Minimum Percent number.
-
Enter a Target Value.
-
Enter an Upper Control Limit and a Lower Control Limit.
-
Select a Unit of Measure from the list.
For example, Each or Lb.
-
Select a Default Corrective Measure from the list.
For example, Open Repair Order, Cancel Work Order, or Work Order On Hold, or No Action Required.
-
-
In the Parameters section, complete the following steps:
-
If this is a pass or fail test, check the Pass Fail Test box.
-
If you require a test pass or fail certification, check the Certificate Required box.
-
If you require a test pass or fail signature, check the Signature Required box.
-
If this test is required, check the This Test is Mandatory box.
-
-
To include a note for this test, in the Notes subtab, complete the following steps:
-
Enter a Title.
-
Enter a Memo.
-
Select a memo Type from the list.
-
Select a memo Direction from the list.
-
To include additional notes, click Add, and then repeat steps a-d.
-
-
To attach a file to this test, click the Files subtab, and then do one of the following in the Attach File field:
-
To select an existing file in NetSuite, click the double arrow, and then click List.
-
To select a new file, click the plus icon, complete the File form, and then click Save.
-
To include additional files, click Add, and then repeat step 7.
-
-
Click Save.