Temperature
Temperature listed is for the server that the card is
installed in. The actual internal ambient inside the server
local to the card might be higher.
|
-5°C to 55°C (-5°C to 131°F), noncondensing
|
-40°C to 70°C (-40°F to 158°F),
noncondensing
|
Humidity
|
10% to 90% noncondensing relative humidity at 27°C
(80.6°F) maximum wet bulb
|
93% noncondensing relative humidity at 38°C (100.4°F)
maximum wet bulb
|
Altitude
|
1,829 meters (6,000 feet) at 45°C (113°F) ambient
1,219 meters (4,000 feet) at 35°C (95°F) ambient
|
12,000 meters (39,370.1 feet)
|
Vibration
|
0.20 G in all axes (20-500 Hz sine)
|
1.0 G in all axes (20-500 Hz sine)
|
Shock
|
1.75g, 32 seconds (VERTEQII -Zone 4 waveform)
40 m/s2 22 ms shock type L
|
100 m/s2 ( 11 ms half-sine)
|
Airflow
|
150 LFM at 55°C (131°F) local ambient
temperature
|
|