Access Module (AEM)
An Access Module has a cartridge access door used for bulk loading of up to 234 tapes. A library with two Access Module supports the redundant robotics feature.
A sliding safety door in the Access Module can separate a defective robot from the rest of the library, allowing a service representative to access the disabled robot while the library remains online.
- Access Modules must be placed on the ends of the library.
- A single Access Module supports bulk loading CAP capabilities only. You should install a single Access Module on the left for an additional 104 storage cells.
- Dual Access Modules support bulk loading and redundant robotics.
- Access Modules and Parking Modules cannot be installed in the same library.
Figure 1-7 Access Module

- Side cover removed showing sliding door
- Bulk load cartridge access door
- Access module service panel and handle
Related Topics
Access Module Measurements
Dimension | Measurement |
---|---|
Height |
196.7 cm (77.45 in.) on casters for transport 197.5 cm (77.75 in.) to 201.68 cm (79.4 in.) on jack pads for permanent install |
Width |
91.4 cm (36.0 in.) when placed between module and side cover 96 cm (37.8 in) transport width (no side covers). This is the minimum transportation clearance because alignment tabs on each side of the module add 4.5 cm to the 91.5 cm width. 99.1 cm (39 in.) with one side cover |
Depth |
77.5 cm (30.5 in.) |
Service Area |
Front: 59.7 cm (23.5 in.) |
Weight |
Frame only: 204.2 kg (450 lb) |