Field-Replaceable Units
The following table lists the field-replaceable units (FRUs) in the server and directs you to the replacement instructions.
FRU | Description | Replacement Instructions |
---|---|---|
CMOD |
Warm-serviceable Add or replace CPU module assemblies (CMOD0-7) including a processor and memory. |
|
Processor and heatsink |
Warm-serviceable Add or replace the Processor Heatsink Module (PHM) CPU that carries out system instructions located in CMODs. |
|
SMOD |
Cold-serviceable Replace system module assemblies SMOD0 or SMOD1. |
|
Storage drive backplanes |
Cold-serviceable Provide power and communications connectors for storage drives located in SMODs. |
|
SAS cable |
Cold-serviceable Provide signals between the SMOD front disk backplane and the Oracle Storage 12Gb SAS PCIe RAID HBA, Internal 16-Port located in SMODs. |
|
Oracle Storage 12 Gb SAS PCIe RAID HBA, Internal card |
Cold-serviceable Located in SMODs, the Oracle Storage 12Gb SAS PCIe RAID HBA, Internal 16-Port manages SAS storage drives. |
|
Front indicator module (FIM) |
Cold-serviceable Contains push-button circuitry and LED indicators that are displayed on the chassis bezel. |
|
Midplane assembly |
Cold-serviceable Internal midplane/busbar assembly in the chassis. |