Go to main content
oracle home
Oracle
®
Server X8-2L Service Manual
Exit Print View
Search Term
» ...
Documentation Home
»
Documentation Library
»
Oracle
®
Server X8-2L Service Manual
»
Index B
Updated: January 2021
Oracle
®
Server X8-2L Service Manual
Document Information
Using This Documentation
Product Documentation Library
Feedback
About the Oracle Server X8-2L
Product Description
Front and Back Panel Components
Front Panel Components
Back Panel Components and Cable Connections
About System Components
Illustrated Parts Breakdown
Customer-Replaceable Units
Field-Replaceable Units
Troubleshooting and Diagnostics
Troubleshooting Server Component Hardware Faults
Troubleshooting Server Hardware Faults
Basic Troubleshooting Process
Related Information
Troubleshoot Hardware Faults Using the Oracle ILOM Web Interface
Troubleshooting and Diagnostic Information
Troubleshooting Using the Server Front and Back Panel Status Indicators
Related Information
Server Boot Process and Normal Operating State Indicators
Server System-Level Status Indicators
Server Fan Status Indicators
Storage Drive Status Indicators
Power Supply Status Indicators
Network Management Port Status Indicators
Ethernet Port Status Indicators
Motherboard Status Indicators
Troubleshooting System Cooling Issues
Troubleshooting Power Issues
Managing Server Hardware Faults Through the Oracle ILOM Fault Management Shell
Troubleshooting With Diagnostic Tools
Diagnostic Tools
Diagnostic Tool Documentation
Attaching Devices to the Server
Attach Devices to the Server
Back Panel Connector Locations
Configuring Serial Port Sharing
Assign Serial Port Output Using the Oracle ILOM CLI
Assign Serial Port Output Using the Oracle ILOM Web Interface
Server Operating System Names for the NVMe Storage Drives
Ethernet Device Naming
Ethernet Port Device Naming
MAC Address Mapping to Ethernet Ports
Back Panel Pinhole Switches
Getting Help
Contacting Support
Locating the Chassis Serial Number
Auto Service Requests
Preparing for Service
Safety Precautions
Safety Symbols
Electrostatic Discharge Safety
FRU Key Identity Properties (KIP) Automated Update
Required Tools
Preparing the Server for Component Replacement
Powering Down the Server
Power Down the Server Gracefully Using the Oracle ILOM CLI
Power Down the Server Gracefully Using the Oracle ILOM Web Interface
Power Down the Server Gracefully Using the On/Standby Button
Power Down the Server for Immediate Shutdown Using the Oracle ILOM CLI
Power Down the Server for Immediate Shutdown Using the Oracle ILOM Web Interface
Power Down the Server for Immediate Shutdown Using the On/Standby Button
Disconnect Cables From the Server
Extend the Server to the Maintenance Position
Remove the Server From the Rack
Take Antistatic Measures
Remove the Server Top Cover
Servicing Storage Drives (CRU)
Storage Drives Hot-Plug Conditions
Storage Drive Failure and RAID
Storage Drive Locations and Numbering
Removing and Replacing a Storage Drive
Remove a Storage Drive
Install a Storage Drive
Removing and Replacing an NVMe Storage Drive Using Oracle Solaris
Unmount an NVMe Storage Drive
Remove an NVMe Storage Drive
Verify Removal of an NVMe Storage Drive
Install an NVMe Storage Drive
Power On an NVMe Storage Drive and Attach a Device Driver
Removing and Replacing an NVMe Storage Drive Using Oracle Linux
Unmount an NVMe Storage Drive
Remove an NVMe Storage Drive
Verify Removal of an NVMe Storage Drive
Install an NVMe Storage Drive
Power On an NVMe Storage Drive and Attach a Device Driver
Verify Operation of an NVMe Storage Drive
Removing and Replacing an NVMe Storage Drive Using Microsoft Windows Server
Remove an NVMe Storage Drive
Install an NVMe Storage Drive
Servicing Fan Modules (CRU)
Remove a Fan Module
Install a Fan Module
Remove the Fan Tray
Install the Fan Tray
Servicing Power Supplies (CRU)
Power Supply Overview
Remove a Power Supply
Install a Power Supply
Servicing the Internal M.2 Flash SSDs (CRU)
Remove a Flash Riser Board
Install a Flash Riser Board
Identify and Remove an M.2 Flash SSD
Install an M.2 Flash SSD
Servicing an Internal USB Flash Drive (CRU)
Remove an Internal USB Flash Drive
Install an Internal USB Flash Drive
Servicing the Air Baffle (CRU)
Remove the Air Baffle
Install the Air Baffle
Servicing the DIMMs (CRU)
DIMM and Processor Physical Layout
DIMM Population Scenarios
DIMM Population Rules
Populating DIMMs for Optimal System Performance
Populating DIMMs in Single-Processor Systems for Optimal System Performance
Populating DIMMs in Dual-Processor Systems for Optimal System Performance
DIMM Operating Speeds
DIMM Rank Classification Labels
Inconsistencies Between DIMM Fault Indicators and the BIOS Isolation of Failed DIMMs
Using the Server Fault Remind Button
Identify and Remove a DIMM
Install a DIMM
Servicing PCIe Cards (CRU)
PCIe Slot Locations
Remove a PCIe Card
Install a PCIe Card
Servicing the Battery (CRU)
Remove the Battery
Install the Battery
Servicing Processors (FRU)
Identify and Remove a Processor
Install a Processor
Servicing the Disk Backplane (FRU)
Remove the Disk Backplane
Install the Disk Backplane
Servicing the Front LED Indicator Module (FRU)
Remove the Front LED Indicator Module
Install the Front LED Indicator Module
Servicing the Temperature Sensor (FRU)
Remove the Temperature Sensor
Install the Temperature Sensor
Servicing the Internal HBA Card (FRU) and HBA Super Capacitor (CRU)
Remove the Internal HBA Card and HBA Super Capacitor
Install the Internal HBA Card and HBA Super Capacitor
Servicing SAS Cables (FRU)
Remove SAS Storage Drive Cables
Install SAS Storage Drive Cables
Servicing NVMe Cables (FRU)
Remove NVMe Cables
Install NVMe Cables
Verify NVMe Cable Connections
Servicing the Motherboard Assembly (FRU)
Remove the Motherboard Assembly
Install the Motherboard Assembly
Returning the Server to Operation
Server Filler Panel Requirements
Remove and Install Filler Panels
Install the Server Top Cover
Remove Antistatic Measures
Reinstall the Server Into the Rack
Return the Server to the Normal Rack Position
Reconnect Power and Data Cables
Power On the Server
Identifying the Server Ports
Gigabit Ethernet Port
Network Management Port
Serial Management Port
USB Ports
Setting Up BIOS Configuration Parameters
Manage the BIOS Configuration
Accessing the BIOS Setup Utility
BIOS Setup Utility Menus
BIOS Key Mappings
Access BIOS Setup Utility Menus
Navigate BIOS Setup Utility Menus
Using UEFI BIOS
Configuration Utilities for Add-In Cards
Configure and Manage BIOS Using Oracle ILOM
UEFI Secure Boot
Trusted Execution Technology
Common BIOS Setup Utility Tasks
Verify BIOS Factory Default Settings
Select a Temporary Boot Device
Configure TPM Support
Configure UEFI Driver Settings
Configure I/O Resource Allocation
Configure UEFI Secure Boot
Configure Trusted Execution Technology
Exit BIOS Setup Utility
BIOS Setup Utility Menu Options
BIOS Main Menu Selections
BIOS Advanced Menu Selections
BIOS Advanced Menu Serial Port Console Redirection Options
BIOS Advanced Menu Network Stack Options
BIOS Advanced Menu NVMe Configuration Options
BIOS Advanced Menu Primary Video Selection Options
BIOS Advanced Menu Trusted Computing 2.0 Options
BIOS Advanced Menu Disk Freeze Lock Settings Options
BIOS Advanced Menu PCH SATA Configuration Options
BIOS Advanced Menu Processor Configuration Options
BIOS Advanced Menu Memory Configuration Option
BIOS Advanced Menu CPU Power Management Configuration Options
BIOS Advanced Menu USB Ports Options
BIOS Advanced Menu Error Injection Settings Options
BIOS Advanced Menu T1s Auth Configuration Options
BIOS Advanced Menu RAM Disk Configuration Options
BIOS Advanced Menu iSCSI Configuration Options
BIOS Advanced Menu Intel Virtual RAID on CPU Options
BIOS Advanced Menu Gigabit Network Connection Options
BIOS Advanced Menu Driver Health Options
BIOS IO Menu Selections
BIOS IO Menu PCI Subsystem Settings Options
BIOS IO Menu IO Virtualization Options
BIOS IO Menu IOAT Configuration Options
BIOS IO Menu PCIE Hardware Slot Configuration Options
BIOS IO Menu Internal Devices Options
BIOS IO Menu Add-in Cards Options
BIOS Boot Menu Selections
BIOS Exit Menu Selections
Monitoring Components and Identifying SNMP Messages
Monitoring Component Health and Faults Using Oracle ILOM
Monitoring System Components
System Chassis Components
Cooling Unit Components
Disk Backplane Components
Memory Device Components
Power Unit Components
Processor Components
System Motherboard Components
System Firmware Components
Hard Disk Drive Components
Identifying SNMP Trap Messages
Environmental Events
Hard Disk Drive Events
Power Events
Fan Events
Memory Events
Entity Presence Events
Index
Index A
Index B
Index C
Index D
Index E
Index F
Index G
Index H
Index I
Index L
Index M
Index N
Index O
Index P
Index R
Index S
Index T
Index U
Index W
Language:
English
B
battery
description
Customer-Replaceable Units
installing
Install the Battery
removing
Remove the Battery
replacing
Servicing the Battery (CRU)
BIOS factory defaults, verifying
Verify BIOS Factory Default Settings
BIOS Setup Utility
accessing
Access BIOS Setup Utility Menus
Advanced screen
BIOS Advanced Menu Selections
Boot screen
BIOS Boot Menu Selections
Exit screen
BIOS Exit Menu Selections
exiting from
Exit BIOS Setup Utility
function keys
BIOS Key Mappings
IO screen
BIOS IO Menu Selections
Main screen
BIOS Main Menu Selections
menus, accessing
Access BIOS Setup Utility Menus
navigating menu options
Navigate BIOS Setup Utility Menus
setup screens summary
BIOS Setup Utility Menus
shortcut key sequences
BIOS Key Mappings
TPM support
Configure TPM Support
UEFI BIOS
Using UEFI BIOS
board components
System Chassis Components
boot device, selecting
Select a Temporary Boot Device
boot drive
LEDs
Storage Drive Status Indicators
boot process
power modes
Server Boot Process and Normal Operating State Indicators
buttons
Fault Remind
Identify and Remove a Processor
On/Standby
Power On the Server
Power Down the Server for Immediate Shutdown Using the On/Standby Button
Power Down the Server Gracefully Using the On/Standby Button
Previous
Next