- Oracle Flash Accelerator F680 PCIe Card User Guide
- Oracle Flash Accelerator F680 PCIe Card Product Information
- Updating Oracle Flash Accelerator F680 PCIe Card Software and Firmware
Updating Oracle Flash Accelerator F680 PCIe Card Software and Firmware
This section provides information on updating Oracle Flash Accelerator F680 PCIe Card firmware and software.
Keep Drivers and Firmware Up to Date
This section provides information on updating Oracle Flash Accelerator F680 PCIe Card drivers, firmware and software.
Product patches, updates and firmware are available on My Oracle Support from the Patches and Updates tab. Refer to the server documentation to check for updates to the device firmware.
Download the Device Software Package
To find the device software package, access My Oracle Support and download the latest software package for Oracle Flash Accelerator F680 PCIe Cards.
- Go to My Oracle Support.
- Sign in to My Oracle Support.
-
At the top of the page, click the Patches &
Updates tab.
The Patch Search pane appears at the right of the screen.
-
Within the Search tab area, click Number/Name
or Bug Number (Simple).
The Search tab area appears with search fields.
- In the Product field, enter the patch number for Oracle Flash Accelerator F680
PCIe Cards.
See Minimum Supported Card Firmware Version.
-
In the Release field, select a software release from the drop-down
list.
Expand the list to see all available software releases.
-
Click Search.
The Patch Advanced Search Results screen appears, listing the patches for the software release.
-
To select a patch for a software release, click the patch number next
to the software release version.
You can use the Shift key to select more than one patch.
A pop-up action panel appears. The panel contains several action options, including the ReadMe, Download, and Add to Plan options. For information about the Add to Plan option, click the associated button and select “Why use a plan?”.
- To review the ReadMe file for this patch, click ReadMe.
- To download the patch for the software release, click Download.
-
In the File Download dialog box, click the patch zip file name.
The patch for the software release downloads. The download is an archive zip file, which you must extract to find the directory containing the image.pkg file.
Update the NVMe Storage Drive Firmware
-
Update your system to the latest software release.
-
Verify that the latest supported software release of Oracle Hardware Management Pack is installed on the host.
For CLI command instructions, refer to Oracle Server CLI Tools User's Guide in Oracle Hardware Management Pack documentation.
This procedure provides instructions to update Oracle F680 Flash Card NAND flash controller firmware on the host for supported Oracle Solaris and Linux operating systems. Oracle F680 Flash Card firmware is updated as a single package using Oracle Hardware Management Pack utility command-line interface (CLI) tools.
Note:
For detailed instructions on system software updates, refer to the server documentation.- Check Oracle Flash Accelerator F680 PCIe Card Product Information for the
latest firmware requirements.
See Minimum Supported Card Firmware Version.
-
Log in to the target system.
For detailed instructions, refer to the server installation guide. For example, to log in to the target system through SSH or through Oracle ILOM Remote System Console Plus, do one of the following:
-
If you are using an SSH client connection.
-
From a shell command line in a terminal window, establish an SSH connection to the server host.
Type: ssh root@hostname , where hostname can be the DNS name or the IP address for the server host.
-
Log in to the system using an account with root access.
-
Proceed to Step 3.
-
-
If you are using a remote system console, first refer to the server Administration Guide and then perform these steps.
To launch an Oracle ILOM Remote System Console Plus session, refer to Launching Remote KVMS Redirection Sessions in the server Administration Guide.
-
Establish a remote connection to the host console.
Start an Oracle ILOM serial console session, type:
-> start /HOST/console
Are you sure you want to start /HOST/console (y/n)? y
-
Ensure that the server is powered on and booted.
-
Access the operating system command-line interface.
You issue Oracle Hardware Management Pack commands from the operating system command-line interface.
-
-
- Download and store any firmware image file updates on the server that are
required to support Oracle Flash Accelerator F680 PCIe Cards.
- Download firmware image files from My
Oracle Support.
See Download the Device Software Package.
- Copy the downloaded firmware image files obtained to the target system root directory.
- Download firmware image files from My
Oracle Support.
- Identify all Oracle Flash Accelerator F680 PCIe Card controller firmware
versions in the server.
- Type
#fwupdate list controller.In the following example, Oracle Flash Accelerator F680 PCIe Card controllers
c5andc6are enumerated in the output returned by the above command.# fwupdate list controller WARNING: Due to strict MMIO memory settings in the running kernel some network controllers may not be accessible. See Hardware Management Pack documentation regarding iomem kernel settings required for firmware update of these devices. ================================================== CONTROLLER ================================================== ID Type Manufacturer Model Product Name FW Version BIOS Version EFI Version FCODE Version Package Version NVDATA Version XML Support ----------------------------------------------------------------------------------------------- c0 NVMe Intel 0x0b60 INTEL SSDPF2NV307TZS ACV1R380 c1 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c2 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c3 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c4 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c5 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c6 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c7 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c8 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c9 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC50 c10 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC50 c11 SAS Samsung 0xa826 MZWLO7T6HBLA-00AU3 OPPA1R5Q c12 SAS 0x025e 0x0b60 SOLIDIGM SBFPF2BV307TOC 5CV1R077 c13 SAS 0x025e 0x0b60 SOLIDIGM SBFPF2BV614TOC 5CV1R077 c14 SAS 0x1344 0x51c3 Micron_7450_MTFDKBA480TFR E2MU200 c15 NVMe Samsung 0xa80a SAMSUNG MZVL2480HBJD-00A07 GDB7302Q - Verify that the firmware package files that are installed in Oracle
Flash Accelerator F680 PCIe Cards require updating.
To identify NVMe controllers that need updated firmware image files, view the
FW Versioncolumn in the output from the fwdupdate list controller command.In the following example, Oracle Flash Accelerator F680 PCIe Card controllers
c9andc10show firmware version2CV1R151, while the other NVMe controllers show firmware version9CV1R410.# fwupdate list controller WARNING: Due to strict MMIO memory settings in the running kernel some network controllers may not be accessible. See Hardware Management Pack documentation regarding iomem kernel settings required for firmware update of these devices. ================================================== CONTROLLER ================================================== ID Type Manufacturer Model Product Name FW Version BIOS Version EFI Version FCODE Version Package Version NVDATA Version XML Support ----------------------------------------------------------------------------------------------- c0 NVMe Intel 0x0b60 INTEL SSDPF2NV307TZS ACV1R380 c1 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c2 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c3 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c4 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c5 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c6 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c7 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c8 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c9 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC51 c10 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC51 c11 SAS Samsung 0xa826 MZWLO7T6HBLA-00AU3 OPPA1R5Q c12 SAS 0x025e 0x0b60 SOLIDIGM SBFPF2BV307TOC 5CV1R077 c13 SAS 0x025e 0x0b60 SOLIDIGM SBFPF2BV614TOC 5CV1R077 c14 SAS 0x1344 0x51c3 Micron_7450_MTFDKBA480TFR E2MU200 c15 NVMe Samsung 0xa80a SAMSUNG MZVL2480HBJD-00A07 GDB7302Q - View the Firmware Revision in the output from the nvmeadm
list -v command.
To identify NVMe controllers and current firmware versions type # nvmeadm list -v.
In the following example, controllers
SUNW-NVME-3andSUNW-NVME-4show firmware version9CV1R410in the output returned by the above command.# nvmeadm list -v SUNW-NVME-1 PCI Vendor ID: 0x144d Serial Number: S78UNE0TA00209 Model Number: SAMSUNG MZVL2480HBJD-00A07 Firmware Revision: GDB7302Q Number of Namespaces: 32 SUNW-NVME-2 PCI Vendor ID: 0x1344 Serial Number: 22283A14CB5C Model Number: Micron_7450_MTFDKBA480TFR Firmware Revision: E2MU200 Number of Namespaces: 132 SUNW-NVME-3 PCI Vendor ID: 0x8086 Serial Number: PHAZ2233000E6P4AGN-2 Model Number: INTEL SSDPFCKE064T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-4 PCI Vendor ID: 0x8086 Serial Number: PHAZ223300016P4AGN-1 Model Number: INTEL SSDPFCKE064T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-5 PCI Vendor ID: 0x8086 Serial Number: PHAZ223300016P4AGN-2 Model Number: INTEL SSDPFCKE064T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-6 PCI Vendor ID: 0x8086 Serial Number: PHAX137400987P6DGN Model Number: INTEL SSDPF2KX076T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-7 PCI Vendor ID: 0x8086 Serial Number: PHAX1456003A15PFGN Model Number: INTEL SSDPF2KX153T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-8 PCI Vendor ID: 0x8086 Serial Number: PHAC2353003930PGGN Model Number: INTEL SSDPF2NV307TZS Firmware Revision: ACV1R330 Number of Namespaces: 128 SUNW-NVME-9 PCI Vendor ID: 0x8086 Serial Number: PHAC2353003D30PGGN Model Number: INTEL SSDPF2NV307TZS Firmware Revision: ACV1R330 Number of Namespaces: 128 SUNW-NVME-10 PCI Vendor ID: 0x8086 Serial Number: PHAZ223300066P4AGN-1 Model Number: INTEL SSDPFCKE064T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-11 PCI Vendor ID: 0x8086 Serial Number: PHAZ223300066P4AGN-2 Model Number: INTEL SSDPFCKE064T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-12 PCI Vendor ID: 0x8086 Serial Number: PHAZ2233000V6P4AGN-2 Model Number: INTEL SSDPFCKE064T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-13 PCI Vendor ID: 0x8086 Serial Number: PHAZ2233000V6P4AGN-1 Model Number: INTEL SSDPFCKE064T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-14 PCI Vendor ID: 0x8086 Serial Number: PHAX1374001G7P6DGN Model Number: INTEL SSDPF2KX076T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-15 PCI Vendor ID: 0x1344 Serial Number: 172310117DB2 Model Number: MTFDKCC30T7TGR Firmware Revision: G0MQ000 Number of Namespaces: 128 SUNW-NVME-16 PCI Vendor ID: 0x8086 Serial Number: PHAX137000ER3P8CGN Model Number: INTEL SSDPF2KX038T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-17 PCI Vendor ID: 0x8086 Serial Number: PHAZ2233000E6P4AGN-1 Model Number: INTEL SSDPFCKE064T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128
- Type
- Quiesce Oracle Flash Accelerator F680 PCIe Card devices.
Before removing the card, manually quiesce I/O and device usage.
Caution:
System hang or data loss. Before updating device firmware, ensure that the device is quiesced and the following events are not occurring:-
The operating system is not accessing the disk (for example, the system boot disk).
-
An application is not accessing the disk (for example, a database application).
-
- Update the selected Oracle Flash Accelerator F680 PCIe Cards with the
specified firmware package.
The
fwupdatecommand can update firmware for all similar devices in the system utilizing an XML metadata file. This method is called Automatic Mode and is the recommended method for upgrades.Note:
Alternately, if you determine that each device must be updated with a separatefwupdatecommand, perform thefwupdateAutomatic Single Drive method, or thefwupdateManual method (if an XML metadata file is not available). For CLI command instructions, refer to Oracle Hardware Management Pack documentation.- Verify that an XML metadata file is available for the server.
An XML metadata file must be included with the firmware update package to use Automatic Mode. Refer to the update package release notes for more information.
- To update device firmware on Oracle Flash Accelerator F680 PCIe Cards,
type
fwupdate update controller -x metadata.xmlIn the following example, controllers
c0andc1will be upgraded to firmware version9CV1R410.#fwupdate update controller -x metadata.xml The following components will be upgraded as shown: ========================================================== ID Priority Action Status Old Firmware Ver. Proposed Ver. New Firmware Ver. System Reboot ------------------------------------------------------------------------------------------------------------------- c0 1 Check FW Success 2CV1R151 9CV1R410 N/A None c1 1 Check FW Success 2CV1R151 9CV1R410 N/A None Do you wish to process all of the above component upgrades? [y/n]?If the current firmware package version on the selected controller is higher than the specified firmware package version, the command returns an error. For error codes, refer to Oracle Hardware Management Pack documentation.
- To upgrade the firmware packages and process all of the above
component upgrades, type
y.Updating c1: Success Updating c2: Success Verifying all priority 1 updates Execution Summary ========================================================== ID Priority Action Status Old Firmware Ver. Proposed Ver. New Firmware Ver. System Reboot ------------------------------------------------------------------------------------------------------------ c0 1 Check FW Success 2CV1R151 9CV1R410 N/A None c1 1 Check FW Success 2CV1R151 9CV1R410 N/A None System Reboot required for some applied firmware Do you wish to automatically reboot now? [y/n]? - Type y to reboot the host server to initialize the firmware update.
- Verify that an XML metadata file is available for the server.
-
Re-access the console. See step 2.
For more instructions, refer to the server Installation Guide.
- Verify that updated firmware packages are installed in Oracle Flash
Accelerator F680 PCIe Cards.
- Type the following from a terminal: #
fwupdate list controllerIn the following example, Oracle Flash Accelerator F680 PCIe Cards
c1-c8are displayed.# fwupdate list controller WARNING: Due to strict MMIO memory settings in the running kernel some network controllers may not be accessible. See Hardware Management Pack documentation regarding iomem kernel settings required for firmware update of these devices. ================================================== CONTROLLER ================================================== ID Type Manufacturer Model Product Name FW Version ---------------------------------------------------------------------------- c0 NVMe Intel 0x0b60 INTEL SSDPF2NV307TZS ACV1R380 c1 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c2 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c3 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c4 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c5 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c6 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c7 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c8 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c9 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC51 c10 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC51 c11 SAS Samsung 0xa826 MZWLO7T6HBLA-00AU3 OPPA1R5Q c12 SAS 0x025e 0x0b60 SOLIDIGM SBFPF2BV307TOC 5CV1R077 c13 SAS 0x025e 0x0b60 SOLIDIGM SBFPF2BV614TOC 5CV1R077 c14 SAS 0x1344 0x51c3 Micron_7450_MTFDKBA480TFR E2MU200 c15 NVMe Samsung 0xa80a SAMSUNG MZVL2480HBJD-00A07 GDB7302Q - Verify host recognition of all Oracle Flash Accelerator F680 PCIe
Cards by checking PCIe ID enumeration.
In the above example, Oracle Flash Accelerator F680 PCIe Card controllers
c1-c8are enumerated in the output returned by the above command. - Ensure that Oracle Flash Accelerator F680 PCIe Card firmware was
updated in the output returned by the above command.
In the above example, Oracle Flash Accelerator F680 PCIe Card controllers
c1toc8show firmware version9CV1R410.
- Type the following from a terminal: #
- Verify Oracle Flash Accelerator F680 PCIe Card operation.
- Repeat the firmware upgrade process until Oracle Flash Accelerator F680 PCIe
Cards have the most up to date firmware release.
See Minimum Supported Card Firmware Version. For example, upgrade firmware revision to 9CV1R410.
Verify Oracle Flash Accelerator F680 PCIe Card Operation
-
Verify that Oracle Hardware Management Pack is installed on the host.
For CLI command instructions, refer to Oracle Hardware Management Pack documentation Oracle Server CLI Tools User's Guide.
-
Ensure that you have access to the server (either directly or over the network).
This procedure provides instructions to verify Oracle Flash Accelerator F680 PCIe Card operation on the host for supported Oracle Linux and Oracle Solaris operating systems. Verify Oracle Flash Accelerator F680 PCIe Card and NVMe SSD operation using Oracle Hardware Management Pack utility CLI tools.
- Observe Oracle Flash Accelerator F680 PCIe Card status indicator LEDs.
Verify that the Fault-Service Action Required Oracle Flash Accelerator F680 PCIe Card status indicator is not lit and that the green Power status indicator is lit on Oracle Flash Accelerator F680 PCIe Cards and NVMe SSDs that you updated.
Refer to LED Status Indicator Characteristics in Oracle Flash Accelerator F680 PCIe Card NVMe Solid State Drive Specification.
- Log in to the target system.
For detailed instructions, refer to the server installation documentation. For example, to log in to the target system through SSH or through Oracle ILOM Remote System Console Plus, do one of the following:
- SSH client connection:
-
From a shell command line in a terminal window, establish an SSH connection to the server host.
Type: ssh root@hostname , where hostname can be the DNS name or the IP address for the server host.
-
Log in to the system using an account with root access.
-
Proceed to Step 3.
-
- Remote system console:
First refer to Start Serial Console Redirection and Log In to Host Server OS at Oracle ILOM Documentation and then perform these steps.
If you are using a remote system console, refer to the server administration documentation and perform these steps.
-
Establish a remote connection to the host console.
Start an Oracle ILOM serial console session, type:
->start /HOST/consoleAre you sure you want to start /HOST/console (y/n)? y
To launch an Oracle ILOM Remote System Console Plus session, refer to Launching Remote KVMS Redirection Sessions in the server administration documentation.
-
Ensure that the server is powered on and booted.
-
Access the operating system command-line interface.
You issue Oracle Hardware Management Pack commands from the operating system command-line interface.
-
Proceed to Step 3.
-
- SSH client connection:
- Identify all Oracle F680 Flash Cards and verify that the latest firmware packages
are installed.
- Type the following command:
.#fwupdate list controllerIn the following example, device controllers are enumerated in the output returned by the above command.
# fwupdate list controller WARNING: Due to strict MMIO memory settings in the running kernel some network controllers may not be accessible. See Hardware Management Pack documentation regarding iomem kernel settings required for firmware update of these devices. ================================================== CONTROLLER ================================================== ID Type Manufacturer Model Product Name FW Version BIOS Version EFI Version FCODE Version Package Version NVDATA Version XML Support ----------------------------------------------------------------------------------------------- c0 NVMe Intel 0x0b60 INTEL SSDPF2NV307TZS ACV1R380 c1 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c2 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c3 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c4 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c5 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c6 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c7 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c8 NVMe Intel 0x0b60 INTEL SSDPFCKE064T1S 9CV1R410 c9 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC50 c10 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC50 c11 SAS Samsung 0xa826 MZWLO7T6HBLA-00AU3 OPPA1R5Q c12 SAS 0x025e 0x0b60 SOLIDIGM SBFPF2BV307TOC 5CV1R077 c13 SAS 0x025e 0x0b60 SOLIDIGM SBFPF2BV614TOC 5CV1R077 c14 SAS 0x1344 0x51c3 Micron_7450_MTFDKBA480TFR E2MU200 c15 NVMe Samsung 0xa80a SAMSUNG MZVL2480HBJD-00A07 GDB7302Q - Verify host recognition of all Oracle F680 Flash Cards by checking
controller ID enumeration.
In the above example, Oracle F680 Flash Card controllers
c1toc8are enumerated in the output returned by the above command. - Ensure that all Oracle F680 Flash Card firmware revisions are current in the
FW Version output returned by the above command.
See Minimum Supported Card Firmware Version.
- Type the following command:
-
Check NVMe device status.
To identify NVMe controllers and current firmware versions, type
#nvmeadm list -v.To identify NVMe controllers that have updated firmware, view the
Firmware Revisionrow in the output from the nvmeadm list -v command.In the following example, controllers
SUNW-NVME-3shows firmware version9CV1R410in the output returned by the above command.# nvmeadm list -v SUNW-NVME-1 PCI Vendor ID: 0x144d Serial Number: S78UNE0TA00209 Model Number: SAMSUNG MZVL2480HBJD-00A07 Firmware Revision: GDB7302Q Number of Namespaces: 32 SUNW-NVME-2 PCI Vendor ID: 0x1344 Serial Number: 22283A14CB5C Model Number: Micron_7450_MTFDKBA480TFR Firmware Revision: E2MU200 Number of Namespaces: 132 SUNW-NVME-3 PCI Vendor ID: 0x8086 Serial Number: PHAZ2233000E6P4AGN-2 Model Number: INTEL SSDPFCKE064T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-4 PCI Vendor ID: 0x8086 Serial Number: PHAZ223300016P4AGN-1 Model Number: INTEL SSDPFCKE064T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-5 PCI Vendor ID: 0x8086 Serial Number: PHAZ223300016P4AGN-2 Model Number: INTEL SSDPFCKE064T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-6 PCI Vendor ID: 0x8086 Serial Number: PHAX137400987P6DGN Model Number: INTEL SSDPF2KX076T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-7 PCI Vendor ID: 0x8086 Serial Number: PHAX1456003A15PFGN Model Number: INTEL SSDPF2KX153T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-8 PCI Vendor ID: 0x8086 Serial Number: PHAC2353003930PGGN Model Number: INTEL SSDPF2NV307TZS Firmware Revision: ACV1R330 Number of Namespaces: 128 SUNW-NVME-9 PCI Vendor ID: 0x8086 Serial Number: PHAC2353003D30PGGN Model Number: INTEL SSDPF2NV307TZS Firmware Revision: ACV1R330 Number of Namespaces: 128 SUNW-NVME-10 PCI Vendor ID: 0x8086 Serial Number: PHAZ223300066P4AGN-1 Model Number: INTEL SSDPFCKE064T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-11 PCI Vendor ID: 0x8086 Serial Number: PHAZ223300066P4AGN-2 Model Number: INTEL SSDPFCKE064T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-12 PCI Vendor ID: 0x8086 Serial Number: PHAZ2233000V6P4AGN-2 Model Number: INTEL SSDPFCKE064T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-13 PCI Vendor ID: 0x8086 Serial Number: PHAZ2233000V6P4AGN-1 Model Number: INTEL SSDPFCKE064T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-14 PCI Vendor ID: 0x8086 Serial Number: PHAX1374001G7P6DGN Model Number: INTEL SSDPF2KX076T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-15 PCI Vendor ID: 0x1344 Serial Number: 172310117DB2 Model Number: MTFDKCC30T7TGR Firmware Revision: G0MQ000 Number of Namespaces: 128 SUNW-NVME-16 PCI Vendor ID: 0x8086 Serial Number: PHAX137000ER3P8CGN Model Number: INTEL SSDPF2KX038T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 SUNW-NVME-17 PCI Vendor ID: 0x8086 Serial Number: PHAZ2233000E6P4AGN-1 Model Number: INTEL SSDPFCKE064T1S Firmware Revision: 9CV1R410 Number of Namespaces: 128 - Check Oracle Flash Accelerator F680 PCIe Card health and SMART information.
To check the selected 6.8 TB NVMe SSD health and SMART (Self-Monitoring, Analysis, and Reporting Technology) information, type:
#nvmeadm getlog -hThe
Critical Warningfield should be zero. A non-zeroCritical Warningfield indicates a SMART Trip.Ensure that Oracle F680 Flash Cards have remaining drive life (
Percentage Used) in the output returned by the above command.#nvmeadm getlog -h SUNW-NVME-1 SMART/Health Information: Critical Warning: 0 Temperature: 315 Kelvin Available Spare: 100 percent Available Spare Threshold: 10 percent Percentage Used: 0 percent Data Unit Read: 0x2fa1c314 of 512k bytes. Data Unit Written: 0x23bd12c7 of 512k bytes. Number of Host Read Commands: 0x3f0bb9308 Number of Host Write Commands: 0x1c2433434 Controller Busy Time in Minutes: 0x525 Number of Power Cycle: 0x56e Number of Power On Hours: 0x55f Number of Unsafe Shutdown: 0x307 Number of Media Errors: 0x0 Number of Error Info Log Entries: 0x0