6 Maintenance
This chapter describes the maintenance information available from the EAGLE ENUM Mobile Number Portability and Tier One Address Resolution feature. The information includes status, alarms (UAMs), and information messages (UIMs).
6.1 Alarms
Refer to Unsolicited Alarm and Information Messages Reference for descriptions and corrective procedures for alarms related to EAGLE features and functions.
For descriptions of and corrective procedures for MPS-related alarms, refer to Alarms and Maintenance Guide for EAGLE Application Processor.
This section lists new Unsolicited Alarm Messages (UAMs) used to support the EAGLE ENUM Mobile Number Portability and Tier One Address Resolution feature.
Table 6-1 Unsolicited Alarm Messages
UAM | Text | Description | Severity | Output Group |
---|---|---|---|---|
084 | IP Connection Unavailable | IP Connection Unavailable | Major | LINK |
085 | IP Connection Available | IP Connection Available | Normal | LINK |
120 | ENUM SYSTEM is not available | The system has no ENUM card which is Active/IS-NR. | Critical | SYSTEM |
121 | ENUM SYSTEM is available | The number of active ENUM cards (IS-NR state) are equal to or more than half the configured ENUM cards. | Normal | SYSTEM |
122 | ENUM SYSTEM normal, card(s) abnormal | The number of active ENUM cards (IS-NR state) are less than half the configured ENUM cards. | Major | SYSTEM |
123 | ENUM SYSTEM is removed | All ENUM cards are deleted from the system. | Normal | SYSTEM |
124 | ENUM Threshold -Level 1 exceeded | CONGLVL1 of ENUM card capacity has been exceeded. | Minor | CARD |
125 | ENUM Threshold -Level 2 exceeded | CONGLVL2 of ENUM card capacity has been exceeded. | Major | CARD |
126 | ENUM Threshold Condition cleared | Congestion was cleared on ENUM card. | Normal | CARD |
127 | ENUM card capacity exceeded | ENUM Card capacity has been exceeded. | Critical | CARD |
129 | ENUM Card TPS normal | ENUM card capacity is normal | Normal | CARD |
132 | Loading failed: table not found | Table not found during loading | Major | CARD |
133 | Loading failed: data read Error | Unable to read data from Table | Major | CARD |
134 | Loading failed: bad checksum returned | Bad Checksum is returned for the table | Major | CARD |
135 | Loading failed: GPL load timeout | GPL Loading Timer is expired | Major | CARD |
136 | Loading failed: data load timeout | Data Loading Timer is expired | Major | CARD |
137 | Loading failed: invalid GPL | Invalid GPL is encountered while loading | Major | CARD |
138 | Loading failed: GPL format error | Error in GPL Format | Major | CARD |
142 | System release alarm cleared | Alarm is cleared for System Release | Normal | SYSM |
143 | System release GPL(s) not approved | GPL is not approved | Minor | SYSM |
144 | System release version unknown | Release version is unknown | Minor | SYSM |
231 | ELAP Operating in Simplex Mode Cleared | ELAP Operating in Simplex Mode Cleared | Normal | MPS |
250 | MPS available | MPS is available now | Normal | MPS |
261 | MPS unavailable | MPS is down | Critical | MPS |
302 | Cooling Fan Failure | Cooling Fan faced Failure | Minor | SYSM |
303 | Cooling Fans Normal | Cooling Fans is Normal | Normal | SYSM |
370 | Critical Platform Failure(s) | Critical Platform Failure(s) | Critical | MPS |
371 | Critical Application Failure(s) | Critical Application Failure(s) | Critical | MPS |
372 | Major Platform Failure(s) | Major Platform Failure(s) | Major | MPS |
373 | Major Application Failure(s) | Major Application Failure(s) | Major | MPS |
374 | Minor Platform Failure(s) | Minor Platform Failure(s) | Minor | MPS |
375 | Minor Application Failure(s) | Minor Application Failure(s) | Minor | MPS |
400 | Alarm cleared by deleting card | Alarm cleared by deleting card | Normal | CARD |
409 | Clock configuration corrected | Clock configuration corrected | Normal | CLCK |
422 | Insufficient extended memory | Insufficient extended memory | Major | CARD |
423 | Card reload attempted | Card reload attempted | Normal | CARD |
441 | Incorrect MBD – CPU | Incorrect MBD – CPU | Major | CARD |
442 | RTDB database capacity is 90% full | RTDB is 90% full | Critical | CARD |
443 | RTDB database is corrupted | RTDB database is corrupted | Major | CARD |
444 | RTDB database is inconsistent | RTDB database is inconsistent | Minor | CARD |
445 | RTDB database has been corrected | RTDB database has been corrected | Normal | CARD |
446 | RTDB database capacity is 80% full | RTDB database capacity is 80% full | Major | CARD |
447 | RTDB database capacity alarm cleared | RTDB database capacity alarm cleared | Normal | CARD |
448 | RTDB database is incoherent | RTDB database is incoherent | Minor | CARD |
449 | RTDB resynchronization in progress | RTDB resynchronization in progress | Major | CARD |
451 | RTDB reload is required | RTDB reload is required | Major | CARD |
47 | Card type not valid for application | Card/Application type mismatch | Major | CARD |
537 | Ethernet error threshold exceeded | Ethernet error threshold exceeded | Major | LINK |
538 | Ethernet error threshold cleared | Ethernet error threshold cleared | Normal | LINK |
539 | Ethernet Interface Down | Ethernet Interface Down | Major | LINK |
540 | Ethernet Interface Up | Ethernet Interface Up | Normal | LINK |
570 | Incompatible flash image for sys rel | Incompatible flash image for sys release | Major | CARD |
629 | ENUM Card TPS normal | ENUM card capacity is normal. | Normal | CARD |
6.2 UIMs
This section lists new Unsolicited Information Messages (UIMs) used to support the EAGLE ENUM Mobile Number Portability and Tier One Address Resolution feature. Refer to Unsolicited Alarm and Information Messages Reference for complete descriptions of all UIM text and formats.
Table 6-2 Unsolicited Information Messages
UIM | Text | Description | Output Group |
---|---|---|---|
1120 | TRBL Queue is full: elements overwritten | TRBL queue is full | SYSM |
1187 | Table Checksum Mismatch | There is a mismatch in Table Checksum | SYSM |
1188 | DB Subset Checksum Mismatch | There is a mismatch in DB Subset Checksum | SYSM |
1194 |
IP connection Refused, RHOST mismatch |
IP connection is Refused as the RHOST is mismatched | SYSM |
1238 | Full database reload initiated | Full database reload is initiated | CARD |
1321 | EAGLE RTDB Birth date Mismatch | RTDB Birth date is mismatched | SYSM |
1322 | EAGLE RTDB Levels Invalid | RTDB Levels are Invalid | SYSM |
1323 | EAGLE/Elap TN Quantity Mismatch | EAGLE/Elap TN Quantity is Mismatch | SYSM |
1324 | EAGLE/Elap NPANXX Quantity Mismatch | EAGLE/Elap NPANXX Quantity is Mismatched | SYSM |
1325 | EAGLE/Elap LRN Quantity Mismatch | EAGLE/Elap LRN Quantity is Mismatch | SYSM |
1326 | EAGLE RTDB Depth Alert | EAGLE RTDB Depth Alert | SYSM |
1331 | IP Route Table Entry Conflict | There is conflict in IP Route table | SYSM |
1463 | ENUM connection established | ENUM connection has changed to an IS-NR state. | LINK |
1464 | ENUM connection terminated | ENUM connection is no longer established. | LINK |
1465 | ENUM card exceeded threshold TPS | The ENUM card TPS is equal to or more than 4000. | CARD |
1466 | ENUM Dflt Prof & query type mismatch | Default ENUM Profile response type and incoming query type do not match. | APSS |
1467 | ENUM msg decode failed | ENUM message validation fails. | APSS |
1468 | ENUM rcvd invalid msg | ENUM query was received with unsupported field values. | APSS |
1469 | ENUM request rejected | ENUM request was rejected coming from invalid IP addresses. | APSS |
1471 | ENUM matching prof for qry not found | ENUM Profile Table is missing entry of matching ENUM query type. | APSS |
6.3 Thermal Management Parameters
The ENUM card supports thermal monitoring to protect the temperature-sensitive hardware components. The processor on the ENUM card can overheat as a result of high ambient temperature or airflow blockage. If the junction temperature increases above operating limits, the CPU halts and the ENUM card shuts itself down to prevent permanent, catastrophic damage. In the event of thermal shutdown all processor activity ceases.
To minimize data loss due to overheating, a graceful shutdown is implemented to detect and alert the user to the increasing thermal conditions. When the CPU temperature rises above nominal range and exceeds a thermal threshold (Temperature Level 1), a major alarm is raised against the ENUM card. If the temperature continues to increase and exceeds a second thermal threshold (Temperature Level 2), a critical alarm is raised against the ENUM card and traffic processing is stopped. When the second thermal threshold is exceeded, the application is notified from the operating system. The state of card will transition to the IN-ANR Restricted state. Table 6-3 shows the thermal events, actions, and alarms.
After the temperature decreases below the Temperature
Level 2 threshold, the raised critical alarm is cleared and the corresponding
major alarm is raised. When the temperature returns to its nominal range (below
Temperature Level 1), a clearing alarm will be raised for the ENUM card and the
ENUM card resumes traffic processing. These thermal thresholds (Temperature
Level 1 and Temperature Level 2) are user-configurable using the
chg-thm-alm
command.
Table 6-3 Thermal Management Parameters
Board Temperature | Actions / Clearing Condition | UAM |
---|---|---|
Temperature Level 1 Exceeded on ENUM card; Major | Major alarm UAM 0078 raised on ENUM card | 0078 Card temperature exceeds nominal lvl:T1 |
Temperature Level 2 Exceeded on ENUM card; Critical | Critical alarm UAM 0077 raised on ENUM card; State of ENUM card transitions to IS-ANR/Restricted | 0077 Card temperature is at critical lvl:T2 |
Temperature abated (cooling below Temp Level 2 but at level 1) | Major alarm UAM 0078 raised on ENUM card; State of ENUM card transitions to IS-NR/Active | 0078 Card temperature exceeds nominal lvl:T1 |
Temperature abated (cooling below Temp Level 1) | Major alarm UAM 0078 cleared | 0079 Card temperature again at nominal level |