5.17 disp-bp
Use this command to display currently active breakpoints in the communication and application processors.
Parameters
- loc (optional)
- The card location as stenciled on the shelf of the system.
- Range:
- 1101 - 1108, 1111 - 1112, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118, 1109, 1110, 1209, 1210, 1309, 1310, 2109, 2110, 2209, 2210, 2309, 2310, 3109, 3110, 3209, 3210, 3309, 3310, 4109, 4110, 4209, 4210, 4309, 4310, 5109, 5110, 5209, 5210, 5309, 5310, 6109, 6110, 1113, 1115
Example
disp-bp:loc=1109:ueng=3
Dependencies
The loc, imt, or card parameter must be specified.
Only one of the loc, imt, and card parameters can be specified in the command.
The imt parameter allows this command to be entered for a card that has not been configured in the system.
The ueng parameter can be specified only for IXP-based cards.
The oamhc GPLID accepts all subsystem values; all other GPLIDs accept only the all subsystem value.
The card location specified by the loc parameter must be in the database.
Values of 1114, 1116, 1117, and 1118 cannot be specified for the loc parameter.
Notes
None
Output
These examples are for x86-based cards:
disp-bp:card=ss7ansi-all
rlghncxa03w 01-03-22 21:14:58 EST EAGLE5 31.3.0
SDS Installed Breakpoint Report from IMT Address H'00f4
Brkpoint-Addr Memory-Dump-Addr Condition-1 Condition-2 Repeat-Count
------------- ---------------- ----------- ----------- ------------
H'003a-H'0001 ANY ANY 0
rlghncxa03w 01-03-22 21:14:58 EST EAGLE5 31.3.0
SDS Installed Breakpoint Report from IMT Address H’000a
BP Address Memory-Dump Address Conditions Rpt Ct Ind
---------- ------------------------- ------------------ ------ ---
H’0000a974 H’000c030c 1- ANY 3 1
Code Breakpoint 2- ANY
H’0000a975 1- ANY PERM 0
Data Write - WORD 2- ANY
H’0000a976 1- ANY 15 0
Any Access - DWORD 2- ANY
H’0000a977 1- ANY PERM 0
Data Read - BYTE 2- ANY
rlghncxa03w 01-03-22 21:14:58 EST EAGLE5 31.3.0
80386/80486 Debug Registers in Use: DR0 DR2 DR3
;
disp-bp:card=vsccp-all:
rlghncxa03w 01-03-22 21:14:58 EST EAGLE5 31.3.0
SDS Installed Breakpoint Report from IMT Address H'0005
BP Address Memory-Dump Address Conditions Rpt Ct Ind
---------- ------------------------- ----------------- ------ ---
H'0000a974 1- ANY 1 0
Code Breakpoint 2- ANY
;
These examples are for IXP-based cards:
disp-bp:loc=1109
tekelecstp 05-01-10 13:58:45 GMT EAGLE5 33.0.0
SDS Installed Breakpoint Report from IMT Address H'00ff
BP Address Memory-Dump Address Conditions Rep Ind CPU
---------- ------------------- --------------------- ---- --- ------
H'000401000 R11+H'0000ffff 1- R15 > H'ffffffff 2 0 ARM
Any Access - 2- R0 <= H'0000ffff
Data value: H'00000000 Data Mask: H'ffffffff
disp-bp:loc=1109:ueng=3
tekelecstp 05-01-10 13:58:45 GMT EAGLE 33.0.0
SDS Installed Breakpoint Report from IMT Address H'00ff
BP Address Memory-Dump Address Conditions Rep Ind CPU
---------- ------------------- --------------------- ---- --- ------
H'00235000 H'00020044 1- ANY PERM 1 UENG 3