A.10 Cards that use the ent-card Command

Table A-9 contains information about cards that use the ent-card command for provisioning.

Table A-9 Valid Card Applications and Types

Card Name (as shown on card label) Part Number Card Type (:type) Application Type (:appl) Maximum Cards in the Database
E5-APP-B

870-3096-01

e5appb

epap

elap

2

2

E5-APP-B 870-3096-02 e5appb lsms

nas

imf

2

1

255

E5-ATM-B

870-2972-01 (R)

limatm

lime1atm

atmansi

atmitu

180 if only one link is provisioned per card. A maximum of 180 links for either application can exist in the system.

E5-E1T1-B†† 870-2970-01

lime1

limt1

ss7ansi

ccs7itu

250 for each application

E5-ENET-B

870-2971-01 (R)

dcm

enet

enetb

stc

ss7ipgw

ipgwi

iplimi

eroute

ips

ipsg

125 for IPGWx

125 for IPLIMx

100 for ipsg

32 for eroute

E5-MCPM-B*

870-3089-01 (R)

mcpm

mcp

250

E5-SM4G***

870-2860-01 (R)

870-2860-02 (R)

dsm

vsccp

18 for use with ELAP

32 for use with EPAP

E5-SM8G-B***

870-2990-01 (R)

dsm

vsccp

18 for use with ELAP

32 for use with EPAP

E5-SM8G-B***

870-2990-01 (R)

dsm

siphc

deirhc

enumhc

16 of the E5-SM8G-B cards connected to ELAP or EPAP for siphc and deirhc

16 of the E5-SM8G-B cards connected to EPAP for enumhc

E5-TSM

870-2943-03 (R)

tsm

gls

8

SLIC

slic

ipsg

siphc

deirhc

enumhc

vsccp

sfapp

40 for use as GTT on IPSG

75 for use as GTT-disabled IPSG

40 for use as Service Module cards

TELCO

870-2904-01

telco

switch

136

* Though the system allows 250 MCPM cards, practical usage is 2.

*** If any MPS-based features are running in the system, up to 25 Service Modules are allowed in the system. If only GTT is running, up to 32 Service Modules can be used in the system with the 50,000 GTT feature.

† † For the E1 or T1 interface, either SS7 application (SS7ANSI or CCS7ITU) can be assigned to these cards. For more information on the E1 or T1 interface go to Appendix A "E1 Interface" or Appendix B "T1 Interface” in the Database Administration - SS7 User's Guide.

Part numbers followed by (R) are ROHS numbers. These numbers are equivalent to the non-ROHS numbers that they are paired with.

***Connectivity to a TekServer 3 (T1200) with EPAP 13.0 or higher or connectivity to an E5-APP-B card with EPAP 15.0 or higher is required for more than 25 Service Module cards.