A UAM Balancing Matrix

The tables in this appendix are in alphabetical order and list Critical, Major, Minor, and Normal alarms that appear for device conditions, and indicate the clearing alarm that appears when each condition is resolved in the system. (Some device conditions are categorized as Normal, and have an associated clearing alarm when the device changes to another Normal condition.)

Note:

A generic clearing alarm, UAM 0500 “Alarm for this entitiy is being cleared,” addresses scenarios where an alarm used to silently remove an active alarm did not make sense for the condition that was being cleared. This UAM is a generic alarm clearing output that applies to all setting alarms (Critical, Major, and Minor).

A.1 AIQ System Alarms

Table A-1 shows the AIQ System alarms and the clearing alarm that appears when each condition is resolved.

Table A-1 AIQ System Alarms

UAM Text UAM Text
Critical Normal
0592 AIQ Subsystem is not available 0595 AIQ Subsystem is available
0594 AIQ Subsystem normal, card(s) abnormal
0593 AIQ Subsystem is disabled 0596 AIQ Subsystem is removed
0594 AIQ Subsystem normal, card(s) abnormal
Minor Normal
0594 AIQ Subsystem normal, card(s) abnormal 0595 AIQ Subsystem is available
0596 AIQ Subsystem is removed

A.2 ATINP System Alarms

Table A-2 shows the critical and minor ATINP System alarms and the clearing alarm that appears when each condition is resolved.

Table A-2 ATINP System Alarms

UAM Text UAM Text
Critical Normal
0565 ATINPQ Subsystem is not available

0568

0569

ATINPQ Subsystem is available

ATINPQ Subsystem is removed

0566 ATINPQ Subsystem is disabled

0568

0569

ATINPQ Subsystem is available

ATINPQ Subsystem is removed

Major Normal
0429 ATINPQ Subsystem degraded, card(s) abnormal

0568

0569

ATINPQ Subsystem is available

ATINPQ Subsystem is removed

Minor Normal
0567 ATINPQ Subsystem normal,card(s) abnormal

0568

0569

ATINPQ Subsystem is available

ATINPQ Subsystem is removed

A.3 Card Alarms

Table A-3 shows the critical, major, and minor card alarms and the clearing alarm that appears when each condition is resolved.

Table A-3 Card Alarms

UAM Text UAM Text
Critical Normal
0077 Card temperature is critical lvl:T2 0079 Card temperature again at nominal levels
0092 MDAL not responding 0093 MDAL alarm cleared
0127 ENUM card capacity exceeded 0126 ENUM Threshold Condition cleared
0442 RTDB database capacity is 95% full 0447 RTDB database capacity alarm cleared
Major Normal
0001 Card has reset 0014 Card is present
0096 Card has been reloaded
0008 Active MASP has become isolated 0009 MASP became active
0010 MASP became standby
0012 Invalid HW for Integrated Measurements 0519 Measurements subsystem available
0013 Card is isolated from the system 0014 Card is present
0096 Card has been reloaded
0031 HIPR2 detected a major Congested Second 0032 HIPR2 Congestion cleared
0053 Standby TDM failure 0054 Standby TDM failure cleared
0078 Card temperature exceeds nominal lvl:T1 0079 Card temperature again at nominal levels
0088 Clocks A and B TSCs are out of sync 0089 Clocks A and B TSCs are re-synchronized
0125 ENUM Threshold -Level 2 exceeded 0126 ENUM Threshold Condition cleared
0132 Loading failed: table not found 0096 Card has been reloaded
0133 Loading failed: data read error
0134 Loading failed: bad checksum returned
0135 Loading failed: GPL load timeout
0136 Loading failed: data load timeout
0137 Loading failed: invalid GPL
0138 Loading failed: GPL format error
0139 Loading failed: disk read prep error
0140 Loading failed: disk read response error
0141 Loading failed: disk read failed
0300 TVG Grant Failure 0301 TVG Grant Recovery
0306 SNM Overload Onset 0307 SNM Overload Abated
0043 Incorrect feature configuration 0423 Card reload attempted
0047 Card type not valid for application
0099 Incompatible HW for provisioned slot
0276 Insufficient HW for IP7 provisioning
0297 Incorrect port configuration
0422 Insufficient extended memory
0441 Incorrect MDB – CPU
0446 RTDB database capacity is 80% full 0447 RTDB database capacity alarm cleared
0449 RTDB re-synchronization in progress 0445 RTDB database has been corrected
0500 Alarm for this entity is being cleared
0443 RTDB database is corrupted 0445 RTDB database has been corrected
0451 RTDB reload is required
0514 Standby MASP is inhibited 0515 Standby MASP is allowed
0901 Card DB load timeout, check GLS card 0902 Card DB is stable
0903 IP Link A is down 0904 IP Link A is up
0905 IP Link B is down 0906 IP Link B is up
0908 HW cannot support purchased TPS rate 0907 HW limiting TPS rate alarm cleared
0051 TSC Sync is in simplex mode 0052 TSC sync feature is available
0466 STC Network Unavailable 0467 STC Network Available
0088 Clocks A and B TSCs are out of sync 0089 Clocks A and B TSCs are re-synchronized
0390 Illegal Address Error 0388 Illegal Address Error Cleared
0391 Card not responding Error 0389 Card responding normally
0573 BERT Test Failed 0574 BERT Test Passed
0575 Card type not HIPR2 0500 Alarm for this entity is being cleared
0548 GTT HexTree DB corrupted. TPS derated 0550 GTT HexTree DB alarm cleared
0549 GTT HexTree DB incoherent. TPS derated
Minor Normal
UAM Text UAM Text
0022 Clock B for card failed, Clock A normal 0025 Clock B for card normal
0023 Clocks A and B for card failed 0026 Clocks A and B for card normal
0030 HIPR2 detected a minor Congested Second 0032 HIPR2 Congestion cleared
0034 Card database is inconsistent 0033 Card database has been corrected
0035 Card database is corrupted
0037 Card backup database is inconsistent 0036 Card backup database has been corrected
0038 Card backup database is corrupted
0044 Real time clock battery low 0045 Real time clock battery restored
0055 Persistent device state tbl corrupt 0057 Persistent device state tbl corrected
0056 Persistent device state tbl diff ver
0102 Motherboard BIP invalid 0103 Motherboard BIP valid
0124 ENUM Threshold -Level 1 exceeded 0126 ENUM Threshold Condition cleared
0145 HS Clock A for card failed, B normal 0148 High Speed Clock A for card normal
0146 HS Clock B for card failed, A normal 0149 High Speed Clock B for card normal
0147 High Speed Clocks A and B for card failed 0159 High Speed Clocks A and B for card normal
0298 Card not using config. SCTP csum method 0299 Config. SCTP csum method alarm cleared
0304 REPT-NMTSK-DSCD: SNM Discard Onset 0305 RECVY-NMTSK-DSCD: SNM Discard Abated
0444 RTDB database is inconsistent 0445 RTDB database has been corrected
0448 RTDB database incoherent
0466 STC Network Unavailable 0467 STC Network Available
0480 Timestamp Invalid 0481 Timestamp Valid
0498 Sanity monitoring is disabled 0499 Sanity monitoring is enabled
0130 Card successfully loaded with data
0400 Alarm cleared by deleting card
0294 REPT-ALMINH: alarm output PERM inhibit
0295 REPT-ALMINH: alarm output enabled
0296 REPT-ALMINH: alarm output TEMP inhibit
0570 Incompatible flash image for sys rel 0423 Card reload attempted
0579 FC Network Unavailable 0580 FC Network Available
0581 Loss of heartbeat 0582 Heartbeat Available
0590 Fast Copy Application De-activated 0591 Fast Copy Application Activated

A.4 CDT (Customer Defined Trouble) Alarms

CDT (Customer Defined Trouble) Alarms shows the critical, major, minor, and normal card alarms and the clearing alarm that appears when each condition is resolved.

Table A-4 CDT (Customer Defined Trouble) Alarms

UAM Text UAM Text
Critical Normal
0058 Critical customer trouble detected 0062 Customer trouble cleared
Major Normal
0059 Major customer trouble detected 0062 Customer trouble cleared
Minor Normal
0060 Minor customer trouble detected 0062 Customer trouble cleared
Normal Normal
0061 Customer trouble detected 0062 Customer trouble cleared

A.5 Clock (Holdover Clock) Alarms

Clock (Holdover Clock) Alarms shows the critical, major, and minor Holdover Clock alarms and the clearing alarm that appears when each condition is resolved.

Table A-5 Clock (Holdover) Alarms

UAM Text UAM Text
Critical Normal
0063 Critical holdover clock trbl detected 0066 Holdover clock trouble cleared
Major Normal
0064 Major holdover clock trouble detected 0066 Holdover clock trouble cleared
Minor Normal
0065 Minor holdover clock trouble detected 0066 Holdover clock trouble cleared

A.6 Clock System Alarms

Table A-6 shows the critical, major, and minor clock alarms and the clearing alarm that appears when each condition is resolved.

Table A-6 Clock System Alarms

UAM Text UAM Text
Critical Normal
0128 All clocks have failed 0113 Clock alarm(s) cleared
Major Normal
0162 1116-P, 1116-S clocks failed 0113 Clock alarms cleared
0164 1114-S, 1116-S clocks failed
0166 1114-S, 1116-P, 1116-S clocks failed
0169 1114-P, 1116-P clocks failed
0170 1114-P, 1116-P, 1116-S clocks failed
0171 1114-P, 1114-S clocks failed
0172 1114-P, 1114-S, 1116-S clocks failed
0173 1114-P, 1114-S, 1116-P clocks failed
Minor Normal
0160 1116-S clock failed 0113 Clock alarms cleared
0161 1116-P clock failed
0163 1114-S clock failed
0165 1114-S, 1116-P clocks failed
0167 1114-P clock failed
0168 1114-P, 1116-S clocks failed

A.7 DCM Alarms

DCM Alarms shows the major DCM alarm and the clearing alarm that appears when the condition is resolved.

Table A-7 DCM Alarms

UAM Text UAM Text
Major Normal
0084 IP Connection Unavailable 0085 IP Connection Available

A.8 DLK Alarms

Table A-8 shows the major and minor DLK alarm and the clearing alarm that appears when the condition is resolved.

Table A-8 DLK Alarms

UAM Text UAM Text
Major Normal
0537 Ethernet error threshold exceeded 0538 Ethernet error threshold cleared
0539 Ethernet Interface Down 0540 Ethernet Interface Up
0588 FC Port De-activated 0589 FC Port Activated
Minor Normal
0155 STP LAN connection unavailable 0156 STP LAN connection available
0536 IP Connection Excess Re-transmits 0084 IP Connection Available
0085 IP Connection Available

A.9 DPC Alarms

DPC Alarms shows the critical, minor, and normal DPC alarms and the clearing alarm that appears when each condition is resolved.

Table A-9 DPC Alarms

UAM Text UAM Text UAM Text
Critical Other Alarm Conditions Which Clear Given Alarm Normal
0313 DPC is prohibited 0312 DPC is restricted 0311 DPC is allowed
0319 REPT-MTPLP-DET: Circ rte det(cong) 0402 Alarm cleared by deleting route
0334 DPC subsystem is Abnormal    
Minor Other Alarm Conditions Which Clear Given Alarm Normal
UAM Text UAM Text UAM Text
0312 DPC is restricted 0313 DPC is prohibited 0311 DPC is allowed
0319 REPT-MTPLP-DET: Circ rte det(cong) 0402 Alarm cleared by deleting route
0334 DPC subsystem is Abnormal    
Normal Other Alarm Conditions Which Clear Given Alarm Normal
0315 Route is restricted 0316 Route is prohibited 0314 Route is allowed
0319 REPT-MTPLP-DET: Circ rte det(cong) 0402 Alarm cleared by deleting route
0316 Route is prohibited 0315 Route is restricted 0314 Route is allowed
0319 REPT-MTPLP-DET: Circ rte det(cong) 0402 Alarm cleared by deleting route

A.10 DPC System Alarms

DPC System Alarms shows the critical and normal DPC System alarms and the clearing alarm that appears when each condition is resolved.

Table A-10 DPC System Alarms

UAM Text UAM Text UAM Text
Critical Other Alarm Conditions Which Clear Given Alarm Normal
0325 DPC subsystem is blocked 0312 DPC is restricted 0324 DPC subsystem is allowed
0319 REPT-MTPLP-DET: Circ rte det(cong) 0327 DPC subsystem has been deleted
0326 DPC subsystem is prohibited 0333 DPC subsystem is Normal
0332 DPC subsystem is prohibited and blocked    
0334 DPC subsystem is Abnormal    
0326 DPC subsystem is prohibited 0312 DPC is restricted 0324 DPC subsystem is allowed
0319 REPT-MTPLP-DET: Circ rte det(cong) 0327 DPC subsystem has been deleted
0325 DPC subsystem is blocked 0333 DPC subsystem is Normal
0332 DPC subsystem is prohibited and blocked    
0334 DPC subsystem is Abnormal    
0332 DPC subsystem is prohibited and blocked 0312 DPC is restricted 0324 DPC subsystem is allowed
0319 REPT-MTPLP-DET: Circ rte det(cong) 0327 DPC subsystem has been deleted
0325 DPC subsystem is blocked 0333 DPC subsystem is Normal
0326 DPC subsystem is prohibited    
0334 DPC subsystem is Abnormal    
0334 DPC subsystem is Abnormal 0319 REPT-MTPLP-DET: Circ rte det(cong) 0324 DPC subsystem is allowed
    0327 DPC subsystem has been deleted
    0333 DPC subsystem is Normal
0319 REPT-MTPLP-DET: Circ rte det(cong)     0340 RCVRY-MTPLP-RST: Circ rte status cleared
0320 REPT-MTPLP-SUST: Sustained circ rt (cong)     0340 RCVRY-MTPLP-RST: Circ rte status cleared
        0337 DPC-SS status changed. When DPC subsystem transitions between prohibited and blocked to either blocked or prohibited only, this UAM is raised.

A.11 DSM Alarms

DSM Alarms shows the major DSM alarm and the clearing alarm that appears when the condition is resolved.

Table A-11 DSM Alarms

UAM Text UAM Text
Major Normal
0084 IP Connection Unavailable 0085 IP Connection Available

A.12 E1 Port Alarms

Table A-12 shows the major E1 alarms and the clearing alarm that appears when each condition is resolved.

Table A-12 E1 Port Alarms

UAM Text UAM Text
Major Normal
0381 REPT-E1F:FAC-E1 LOS failure 0386 RCVRY-E1F:FAC-E1 available
0382 REPT-E1F:FAC-E1 LOF failure
0383 REPT-E1F:FAC-E1 AIS detected
0384 REPT-E1F:FAC-E1 Far End failure
0385 REPT-E1F:FAC-E1 10E-3 BER failed
0387 REPT-E1F:FAC-E1 unavailable

A.13 EIR Alarms

Table A-13 shows the critical and minor EIR alarms and the clearing alarm that appears when each condition is resolved.

Table A-13 EIR Alarms

UAM Text UAM Text
Critical Normal
0455 EIR System is not available 0458 EIR Subsystem is available
0459 EIR Subsystem is removed
0456 EIR Subsystem is disabled 0458 EIR Subsystem is available
0459 EIR Subsystem is removed
Major Normal
0460 EIR Subsystem degraded, card(s) abnormal 0458 EIR Subsystem is available
0459 EIR Subsystem is removed
Minor Normal
0457 EIR Subsystem normal,card(s) abnormal 0458 EIR Subsystem is available
0459 EIR Subsystem is removed

A.14 ENET System Alarms

Table A-14 shows the ENET System alarms and the clearing alarm that appears when each condition is resolved.

Table A-14 ENET System Alarms

UAM Text UAM Text
Major Normal
0537 Ethernet error threshold exceeded 0538 Ethernet error threshold cleared
0539 Ethernet Interface Down 0540 Ethernet Interface Up
Minor Normal
0536 IP Connection Excess Retranmists 0085 IP Connection Available

A.15 ENUM System Alarms

Table A-15 shows the ENUM System alarms and the clearing alarm that appears when each condition is resolved.

Table A-15 ENUM System Alarms

UAM Text UAM Text
Critical Normal
0120 ENUM SYSTEM is not available 0121 ENUM SYSTEM is available
0123 ENUM SYSTEM is removed
Major Normal
0122 ENUM SYSTEM normal, card(s) abnormal 0121 ENUM SYSTEM is available
0123 ENUM SYSTEM is removed

A.16 EROUTE Alarms

Table A-16 shows the critical, major, and minor EROUTE alarms and the clearing alarm that appears when each condition is resolved.

Table A-16 EROUTE Alarms

UAM Text UAM Text
Critical Normal
0468 All STC Networks Unavailable 0470 EROUTE is Removed
0469 All STC Cards Unavailable 0471 EROUTE System is Available
Major Normal
0473 EROUTE System Capacity Exceeded 0470 EROUTE is Removed
0482 Card(s) have been denied EROUTE service 0471 EROUTE System is Available
Minor Normal
0472 EROUTE System Threshold Exceeded 0470 EROUTE is Removed
0471 EROUTE System is Available
0474 EROUTE capacity normal, card(s) abnormal 0470 EROUTE is Removed
0471 EROUTE System is Available
0475 NTP Time Unavailable 0476 NTP Time Available

A.17 Ethernet Error Threshold Alarms

Table A-17 shows the major ethernet error threshold alarms and the clearing alarm that appears when each condition is resolved.

Table A-17 Ethernet Error Threshold Alarms

UAM Text UAM Text
Major Normal
0537 Ethernet error threshold exceeded 538 Ethernet error threshold cleared
0539 Ethernet Interface Down 0540 Ethernet Interface Up

A.18 Fast Copy System Alarms

Table A-18 shows the major and minor Fast Copy System alarms and the clearing alarm that appears when the condition is resolved.

Table A-18 Fast Copy System Alarms

UAM Text UAM Text
Major Normal
0576 All FC Network Unavailable 0577 All FC cards removed
0578 FC System is Available
Minor Normal
597 FC System is Deactivated 0578 FC System is Available

A.19 Frame Alarms

Table A-19 shows the major Frame alarms and the clearing alarms that appear when the condition is resolved.

Table A-19 Frame Alarms

UAM Text UAM Text
Critical Normal
0520 Frame power usage reached LVL3 0523 Frame power usage normal
Major Normal
0521 Frame power usage reached LVL2 0523 Frame power usage normal
Minor Normal
0522 Frame power usage reached LVL1 0523 Frame power usage normal

A.20 Fuse Alarms

Table A-20 shows the major fuse alarm and the clearing alarm that appears when the condition is resolved.

Table A-20 Fuse Alarms

UAM Text UAM Text
Major Normal
0082 Alarm in fuse panel 0083 Fuse panel alarm has cleared

A.21 GLS Alarms

Table A-21 shows the critical and major GLS alarms and the clearing alarm that appears when each condition is resolved.

Table A-21 GLS Alarms

UAM Text UAM Text
Critical Normal
0292 GLS is not available 0290 GLS is available
0293 GLS have been removed from the system
Major Normal
0291 GLS is at minimum service limit 0290 GLS is available
0293 GLS have been removed from the system
0450 Invalid HW for Integrated GLS 0290 GLS is available

A.22 GPL Alarms

GPL Alarms shows the minor GPL alarms and the clearing alarm that appears when each condition is resolved.

Table A-22 GPL Alarms

UAM Text UAM Text
Critical Normal
0002 Card is not running approved GPL 0003 Alarm cleared for GPL
0004 Card is running non-activated GPL 0005 Alarm cleared running non-activated GPL
0040 GPL is corrupted 0039 GPL has been corrected

A.23 Group Broadcast Alarms

Table A-23 shows the critical and minor Group Broadcast alarms and the clearing alarm that appears when each condition is resolved.

Table A-23 Group Broadcast Alarms

UAM Text UAM Text
Critical Normal
0015 Group Broadcast Registration Failed 0017 Group Broadcast Registration Succeeded
Minor Normal
0016 Single IMT Bus GB Registration 0017 Group Broadcast Registration Succeeded

A.24 GTT Alarms

Table A-24 shows the major GTT alarm and the clearing alarm that appears when the condition is resolved.

Table A-24 GTT System Alarms

UAM Text UAM Text
Critical Normal
0630 Throttle Threshold - exceeded 0631 Throttle Threshold - cleared

A.25 HS Clock System Alarms

Table A-25 shows the critical, major, and minor HS Clock System alarms and the clearing alarm that appears when each condition is resolved.

Table A-25 HS Clock System Alarms

UAM Text UAM Text
Critical Normal
0197 All high speed clocks have failed 0198 High Speed clock alarm(s) cleared
Major Normal
0185 1116-PHS, 1116-SHS clocks failed 0198 High Speed clock alarm(s) cleared
0187 1114-SHS, 1116-SHS clocks failed
0189 1114-SHS, 1116-PHS,1116-SHS clks failed
0192 1114-PHS, 1116-PHS clocks failed
0193 1114-PHS, 1116-PHS,1116-SHS clks failed
0194 1114-PHS, 1114-SHS clocks failed
0195 1114-PHS, 1114-SHS, 1116-SHS clks failed
0196 1114-PHS, 1114-SHS, 1116-PHS clks failed
403 1114 E1/T1 clock requires TDM-GTI 409 Clock configuration corrected
404 1116 E1/T1 clock requires TDM-GTI
405 1114, 116 E1/T1 clock requires TDM-GTI
406 1114 Clock selection mismatch
407 1116 Clock selection mismatch
408 1114, 1116 Clock selection mismatch
Minor Normal
0183 1116-SHS clock failed 0198 High speed clock alarm(s) cleared
0184 1116-PHS clock failed
0186 1114-SHS clock failed
0188 1114-SHS, 1116-PHS clocks failed
0190 1114-PHS clock failed
0191 1114-PHS, 1116-SHS clocks failed

A.26 IMT Bus Alarms

Table A-26 shows the major, minor, and normal IMT Bus alarms and the clearing alarm that appears when each condition is resolved.

Table A-26 IMT Bus Alarms

UAM Text UAM Text
Major Normal
0108 Major IMT failure detected 0106 IMT bus alarm cleared
Minor Normal
0107 Minor IMT failure detected 0106 IMT bus alarm cleared
Normal Normal
0098 IMT inhibited 0097 IMT allowed

A.27 IMT System Alarms

Table A-27 shows the critical, major, and minor IMT System alarms and the clearing alarm that appears when each condition is resolved.

Table A-27 IMT System Alarms

UAM Text UAM Text
Critical Normal
0112 Major failures detected on both IMTs 0109 All IMT system level alarms cleared
Major Normal
0028 IMT Bus util rate exceeds major thresh 0029 IMT Bus utilization threshold cleared
0111 Failure on both IMT A and IMT B 0109 All IMT system level alarms cleared
0563 IMT Bit rate mismatch detected 0564 IMT Bit rate mismatch cleared
Minor Normal
0027 IMT Bus util rate exceeds minor thresh 0029 IMT Bus utilization threshold cleared
0110 Failure detected on one IMT bus 0109 All IMT system level alarms cleared

A.28 INP System Alarms

INP System Alarms shows the critical and minor NP System alarms and the clearing alarm that appears when each condition is resolved.

Table A-28 INP System Alarms

UAM Text UAM Text
Critical Normal
0395 INP Subsystem is not available 0394 INP Subsystem is available
0396 INP Subsystem is disabled 0397 INP Subsystem is removed
Major Normal
0428 INP Subsystem degraded, card(s) abnormal 0394 INP Subsystem is available
Minor Normal
0398 INP Subsystem normal, card(s) abnormal 0394 INP Subsystem is available
0397 INP Subsystem is removed

A.29 IP7CONN Alarms

IP7CONN Alarms shows the major and minor IP Connection alarms and the clearing alarm that appears when each condition is resolved.

Table A-29 IP Connection Alarms

UAM Text UAM Text
Major Normal
0084 IP Connection Unavailable 0085 IP Connection Available
0087 IP Connection manually removed
Minor Normal
0086 IP Connection Congested 0085 IP Connection Available
0087 IP Connection manually removed
0535 IP Connection Restricted 0085 IP Connection Available
0536 IP Connection Excess Retransmits 0085 IP Connection Available

A.30 IP7 Alarms

IP7 Alarms shows the major and minor IP Connection alarms and the clearing alarm that appears when each condition is resolved.

Table A-30 IP Connection Alarms

UAM Text UAM Text
Major Normal
0277 AS Unavailable 0278 AS Available
Minor Normal
0279 AS Restricted 0280 AS Unrestricted

A.31 Linkset Alarms

Table A-31 shows the Linkset alarm and the clearing alarms that appears when the condition is resolved.

Table A-31 Linkset Alarms

UAM Text UAM Text
Major Normal
0115 Linkset IP TPS threshold exceeded 0118 Linkset IP TPS threshold normal
0318 REPT-LKSTO: link set prohibited 0317 RCVRY-LKSTO: link set allowed
0399 RRCVRY-LKSTO:Alarm clr’d by deleting SLK
0560 REPT-LKSTO: link set restricted 0317 REPT-LKSTO: link set restricted

A.32 LNP System Alarms

Table A-32 shows the critical and major LNP System alarms and the clearing alarm that appears when each condition is resolved.

Table A-32 LNP System Alarms

UAM Text UAM Text
Critical Normal
0424 LNP Subsystem is not available 0426 LNP Subsystem is available
0435 LNP Subsystem is disabled 0434 LNP Subsystem is removed
0287 RTDB Table Level 2 FAK Cap exceeded 0289 RTDB Table FAK Capacity Normal
Major Normal
0283 LNP Ported NPAs approaching Feat. Capacity 0284 LNP Ported NPAs Capacity Normal
0285 LNP Ported LRNs approaching Feat. Capacity 0286 LNP Ported LRNs Capacity Normal
0288 RTDB Table Level 1 FAK Cap exceeded 0289 RTDB Table FAK Capacity Normal
0427 LNP Subsystem degraded, card(s) abnormal 0426 LNP Subsystem is available
0436 LNP ACG node overload 0426 LNP Subsystem is available
Minor Normal
0425 LNP Subsystem normal, card(s) abnormal 0426 LNP Subsystem is available

A.33 LSMS Connection Alarms

LSMS Connection Alarms shows the critical and major LSMS Connection alarms and the clearing alarm that appears when each condition is resolved.

Table A-33 LSMS Connection Alarms

UAM Text UAM Text
Critical Normal
0041 LNP DB Maintenance required. 0042 LSMS bulk load complete.
Major Normal
0358 LSMS connection unavailable 0359 LSMS connection available

A.34 LSMS System Alarms

LSMS System Alarms shows the critical and major LSMS System alarms and the clearing alarm that appears when each condition is resolved.

Table A-34 LSMS System Alarms

UAM Text UAM Text
Critical Normal
0356 LSMS unavailable 0355 LSMS is available
0357 All OAP terminals are removed
0350 OAP terminals inhibited 0355 LSMS is available
0357 All OAP terminals are removed
Major Normal
0341 OAP unavailable 0353 OAP is available
0354 One OAP terminal unavailable 0357 All OAP terminals are removed
0362 LSMS is at min service limit 0355 LSMS is available
0357 All OAP terminals are removed

A.35 MCPM Alarms

MCPM Alarms shows the major MCPM alarm and the clearing alarm that appears when the condition is resolved.

Table A-35 MCPM Alarms

UAM Text UAM Text
Major Normal
0084 IP Connection Unavailable 0085 IP Connection Available

A.36 MEAS System Alarms

MEAS System Alarms shows the critical, major, and minor MEAS System alarms and the clearing alarm that appears when each condition is resolved.

Table A-36 MEAS System Alarms

UAM Text UAM Text
Critical Normal
0518 Measurements subsystem unavailable 0519 Measurements subsystem available
Major Normal
0517 Degraded Mode - multiple cards failed 0519 Measurements subsystem available
Minor Normal
0516 Degraded Mode - 1 card failed 0519 Measurements subsystem available

A.37 MPS (ELAP/EPAP) Alarms

Table A-37 shows the critical, major, and minor MPS (ELAP/EPAP) alarms and the clearing alarm that appears when each condition is resolved.

Table A-37 MPS (ELAP/EPAP) Alarms

UAM Text UAM Text
Critical Normal
0370 Critical Platform Failure(s) 0250 MPS available
0371 Critical Application Failure(s)
0261 MPS unavailable
Major Normal
0372 Major Platform Failure(s) 0250 MPS available
0373 Major Application Failure(s)
Minor Normal
0374 Minor Platform Failure(s) 0250 MPS available
0375 Minor Application Failure(s)  

Note:

Critical Platform/Application alarms cause the MPS to go OOS-MT and Major/Minor Platform/Applications alarms cause the MPS to go IS-ANR.

A.38 MPS Alarm Support

The MPS running software release 2.0 (ELAP) or higher. Release 27.0 supports MPS alarms (370-375) and UAMs 442-451 against a card.

Table A-38 MPS Alarm Support

  Release 27.0 and higher
UAM Format

0442

0446

0447

CARD

0443-0445

0448-0451

CARD
0370-0375 MPS1
0250 MPS2

A.39 RTX System Alarms

Table A-39 shows the major RTX system alarms and the clearing alarm that appears when the condition is resolved.

Table A-39 RTX System Alarms

UAM Text UAM Text UAM Text
Critical Other alarm conditions which clear given alarm Normal
0534 RTX is prohibited 0533 RTX is restricted 0532 RTX is allowed
0319 REPT-MTPLP-DET: Circ rte det(cong) 0402 Alarm cleared by deleting route
Minor Other alarm conditions which clear given alarm Normal
0533 RTX is restricted 0534 RTX is prohibited 0532 RTX is allowed
0319 REPT-MTPLP-DET: Circ rte det(cong) 0402 Alarm cleared by deleting route

A.40 SCCP Service Alarms

Table A-40 shows the critical, major, and minor SCCP service alarms and the clearing alarm that appears when each condition is resolved.

Table A-40 SCCP Service Alarms

UAM Text UAM Text
Critical Normal
0528 Service is not available 0526 Service is available
0530 Service is removed
0529 Service is disabled 0526 Service is available
0530 Service is removed
Major Normal
0547 Service degraded 0526 Service is available
0530 Service is removed
Minor Normal
0527 Service abnormal 0526 Service is available
0530 Service is removed

A.41 SCCP System Alarms

Table A-41 shows the critical, major, and minor SCCP system alarms and the clearing alarm that appears when each condition is resolved.

Table A-41 SCCP System Alarms

UAM Text UAM Text
Critical Normal
0331 SCCP is not available 0328 SCCP is available
0335 SCCP is removed
0437 System SCCP TPS Capacity Exceeded 0329 System SCCP TPS normal
0453 Exceeded Service Error Threshold Lvl 2 0454 Service Error Threshold Alarm Cleared
Major Normal
0262 GTT Duplicate Actn processing stopped 0263 GTT Duplicate Actn processing resumed
0336 LIM(s) have been denied SCCP service 0328 SCCP is available
0335 SCCP is removed
0452 Exceeded Service Error Threshold Lvl 1 0454 Service Error Threshold Alarm Cleared
Minor Normal
0330 System SCCP TPS Threshold exceeded 0329 System SCCP TPS normal
0335 SCCP is removed
0632 Alarm Threshold - exceeded 0631 Throttle Threshold - cleared
0633 Alarm Threshold - cleared

A.42 SCTP Retransmit Alarms

SCTP Retransmit Alarms shows the critical, major, and minor SCTP retransmit alarms and the clearing alarm that appears when each condition is resolved.

Table A-42 SCTP Retransmit Alarms

UAM Text UAM Text
Minor Normal
0536 IP Connection Excess Retransmits 0085 IP Connection Available

A.43 SEAS OAP Alarms

Table A-43 shows the major and minor SEAS OAP alarms and the clearing alarm that appears when each condition is resolved.

Table A-43 SEAS OAP Alarms

UAM Text UAM Text
Major Normal
0341 OAP unavailable 0353 OAP is available
0342 SEAS UAL unavailable
0354 One OAP terminal unavailable
0360 EMS Agent unavailable 0361 EMS Agent available
Minor Normal
0364 Configuration data checksum mismatch 0365 Configuration data checksum alarm cleared
0363 OAP filesystem full 0361 EMS Agent available

A.44 SEAS System Alarms

SEAS System Alarms shows the critical and major SEAS System alarms and the clearing alarm that appears when each condition is resolved.

Table A-44 SEAS System Alarms

UAM Text UAM Text
Critical Normal
0349 SEAS unavailable 0351 SEAS is available
0350 OAP terminals inhibited 0352 SEAS is removed
Major Normal
0348 SEAS is at min service limit 0351 SEAS is available
0352 SEAS is removed

A.45 SEAS X25 Alarms

Table A-45 shows the major and minor SEAS X25 alarms and the clearing alarm that appears when each condition is resolved.

Table A-45 SEAS X25 Alarms

UAM Text UAM Text
Major Normal
0343 SEAS X.25 Link unavailable 0347 SEAS X.25 Link is available
0345 All SEAS UAL sessions unavailable
Minor Normal
0344 SEAS PVC unavailable 0347 SEAS X.25 Link is available
0346 SEAS UAL session unavailable

A.46 Security Log Alarm

Security Log Alarm shows the minor and normal Security Log alarms and the clearing alarm that appears when each condition is resolved.

Table A-46 Security Log Alarms

UAM Text UAM Text
Minor Normal
0174 %full threshold reached-upload required 0177 Security log exception cleared
0175 LOGGUFROVFL-SECUL–G - upload required
0176 Stby security log – upload required
Normal Normal
0178 Security log failed 0177 Security log exception cleared

A.47 Security System Alarms

Table A-47 shows the major Security System alarm and the clearing alarm that appears when the condition is resolved.

Table A-47 Security System Alarms

UAM Text UAM Text
Major Normal
0392 OA&M IP Security feature status is OFF 0393 OA&M IP Security feature status is ON
0199 OA&M IP Security feature disabled
Minor Normal
0157 OA&M Security Feature Risk detected 0158 OA&M Security Feature Risk cleared

A.48 SFAPP System Alarms

SFAPP System Alarms shows the critical, major, and minor SFAPP system alarm and the clearing alarm that appears when the condition is resolved.

Table A-48 SFAPP System Alarms

UAM Text UAM Text
Critical Normal
0543 VLR Dynamic Learning is suspended 0544 VLR Dynamic Learning Started
0646 SFAPP Dynamic Learning Alarm Cleared
0635 SFLOG SYSTEM is not available 0634 SFLOG SYSTEM is available
0639 SFAPP Threshold Level Critical 0640 SFAPP Threshold Condition Cleared
0644 System SFAPP capacity Exceeded 0636 SFAPP is removed
Major Normal
0638 SFAPP Threshold Level2 Exceeded 0640 SFAPP Threshold Condition Cleared
0643 System SFAPP TPS Exceeded 0642 SFAPP Threshold normal
0647 EEDB Connectivity Down 0648 EEDB Connectivity Up
Minor Normal
0637 SFAPP Threshold Level1 Exceeded 0640 SFAPP Threshold Condition Cleared
0642 SFAPP Threshold normal
0641 SFAPP Capacity normal, card(s) abnormal 0636 SFAPP is removed
0645 LIM/SCCP card(s) denied SFAPP service

A.49 SFLOG System Alarms

Table A-49 shows the critical SFLOG system alarm and the clearing alarm that appears when the condition is resolved.

Table A-49 SFLOG System Alarms

UAM Text UAM Text
Critical Normal
0627 SFLOG SYSTEM is not available 0628 SFLOG SYSTEM is available
0629 SFLOG SYSTEM is removed

A.50 SLK Alarms

Table A-50 shows the major, minor, and normal SLK alarms and the clearing alarm that appears when each condition is resolved.

Table A-50 SLK Alarms

UAM Text UAM Text
Major Normal
0201 REPT-LKF: remote NE loopback 0223 REPT-LKF: remote NE loopback cleared
0401 Alarm cleared by deleting SLK
0202 REPT-LKF: HWP -too many interrupts 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0203 REPT-LKF: lost data 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0204 REPT-LKF: XER-ERM threshold exceeded 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0205 REPT-LKF: APF - lvl-2 T1 expd (ready) 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0206 REPT-LKF: APF -lvl-2 T1 expd(not ready) 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0207 REPT-LKF: APF - lvl-2 T3 expired 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0208 REPT-LKF: APF - lvl-2 T2 expired 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0209 REPT-LKF: APF - failed proving period 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0210 REPT-LKF: OSA - received SIO 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0211 REPT-LKF: OSA - received SIN 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0212 REPT-LKF: OSA - received SIE 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0213 REPT-LKF: OSA - received SIOS 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0214 REPT-LKF: ABN - rcvd 2 of 3 invalid BSN 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0215 REPT-LKF: ABN - rcvd 2 of 3 invalid FIB 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0216 REPT-LKF: remote congestion timeout 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0217 REPT-LKF: XDA - excess acknowledge delay 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0218 REPT-LKF: COO - rcvd changeover order 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0219 REPT-LKF: false congestion restart 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0222 REPT-LKF: remote FE loopback 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0224 REPT-LKF: link test failed 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0230 REPT-LKF: local blocked - thermal 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0232 REPT-LKF: remote blocked 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0233 REPT-LINK-MANUAV: local blocked 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0234 REPT-LKF: RMI remote inhibited 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0235 REPT-LINK-MGTINH: local inhibited 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0236 REPT-LKF: not aligned 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0237 REPT-LKF: LM Timer NO-CREDIT expired 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0238 REPT-LKF: XDA-Timer NO-RESPONSE expired 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0239 REPT-LKF: MBL - local processor outage 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0240 REPT-LKF: rcvd remote processor outage 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0241 REPT-LKF: rcvd remote out of service 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0242 REPT-LKF: rcvd remote protocol error 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0243 REPT-LKF: rcvd remote mgmnt initiated 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0244 REPT-LKF: FAC - DS1/E1 LOS failure 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0245 REPT-LKF: FAC - DS1/E1 LOF failure 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0246 REPT-LKF: FAC - DS1/E1 LCD failure 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
0247 REPT-LKF: XER - ISERM threshold exceeded 0200 RCVRY-LKF: link available
0401 Alarm cleared by deleting SLK
Minor Normal
0116 Link expected IP TPS threshold exceeded 0119 LinkIPTPS threshold normal
0477 Congestion: Copy Function De-activated 0479 Link not monitored
0531 Insufficient HW Copy Function Inhibited 0478 Copy Function Activated
0479 Link not monitored
0583 Unexpected SAM Received 0584 Expected SAM Received
Normal Normal
0264 REPT-LINK-CGST: congestion level 0 to 1 0269 RCVRY-LINK-CGST:congestion has cleared
0265 REPT-LINK-CGST: congestion level 1 to 2 0268 RCVRY-LINK-CGST:congestion level 2 to 1
0269 RCVRY-LINK-CGST:congestion has cleared
0266 REPT-LINK-CGST: congestion level 2 to 3 0267 RCVRY-LINK-CGST:congestion level 3 to 2
0269 RCVRY-LINK-CGST:congestion has cleared
0270 REPT-LINK-CGST: discard level 0 to 1 0275 RVCRY-LINK-CGST: discard has cleared
0271 REPT-LINK-CGST: discard level 1 to 2 0274 RVCRY-LINK-CGST: discard level 2 to 1
0275 RVCRY-LINK-CGST: discard has cleared
0272 REPT-LINK-CGST: discard level 2 to 3 0273 RVCRY-LINK-CGST: discard level 3 to 2
0275 RVCRY-LINK-CGST: discard has cleared

A.51 <subsystem> System Alarms

Table A-51 shows system alarms that may occur for different subystems and the clearing alarm that appears when each condition is resolved. The name of the subsystem varies.

Table A-51 <subsystem> System Alarms

UAM Text UAM Text
Critical Normal
0592 <subsystem> Subsystem is not available 0595 <subsystem> Subsystem is available
0594 <subsystem> Subsystem normal, card(s) abnormal
0593 <subsystem> Subsystem is disabled 0596 <subsystem> Subsystem is removed
0594 <subsystem> Subsystem normal, card(s) abnormal
Major Normal
0598 <subsystem> degraded, card(s) abnormal 0595 <subsystem> Subsystem is available
0596 <subsystem> Subsystem is removed
Minor Normal
0594 <subsystem> Subsystem normal, card(s) abnormal 0595 <subsystem> Subsystem is available
0596 <subsystem> Subsystem is removed

A.52 System Alarms

Table A-52 shows the critical, major, and minor System alarms and the clearing alarm that appears when each condition is resolved.

Table A-52 System Alarms

UAM Text UAM Text
Critical Normal
0308 Node isolated due to SLK failures 0309 Node is no longer isolated
0368 Temp Keys(s) have expired. 0366 Temp Key(s) expiration alarm cleared
0438 Degraded Mode, Invalid OAM HW config 0439 Exiting Degraded Mode
0561 Can't establish Hi Bit rate;All HW OK 0562 Hi Bit rate established
Major Normal
0011 Entering forced simplex mode 0018 Exiting forced simplex mode
0367 Temp Keys(s) expiring soon. 0366 Temp Key(s) expiration alarm cleared
0911 Dynamic database is inconsistent 0912 Dynamic database is now consistent
Minor Normal
0302 Cooling fan failure 0303 Cooling fans normal

A.53 System GPL Alarms

Table A-53 shows the minor GPL alarms and the clearing alarm that appears when each condition is resolved.

Table A-53 System GPL Alarms

UAM Text UAM Text
Minor Normal
0143 System release GPL(s) not approved 0142 System release alarm cleared
0144 System release version unknown

A.54 T1 Port Alarms

Table A-54 shows the major T1 alarms and the clearing alarm that appears when each condition is resolved.

Table A-54 T1 Port Alarms

UAM Text UAM Text
Major Normal
0369 REPT-T1F:FAC-T1 unavailable 0380 RCVRY-T1F:FAC-T1 available
0376 REPT-T1F:FAC-T1 LOS failure
0377 REPT-T1F:FAC-T1 LOF failure
0378 REPT-T1F:FAC-T1 Remote Alarm
0379 REPT-T1F:FAC-T1 Alarm

A.55 Terminal Alarms

Table A-55 shows the minor Terminal alarm and the clearing alarm that appears when the condition is resolved.

Table A-55 Terminal Alarms

UAM Text UAM Text
Minor Normal
0048 Terminal failed 0046 Terminal enabled

A.56 V-Flex System Alarms

Table A-56 shows the major and minor X-LIST alarms and the clearing alarm that appears when each condition is resolved.

Table A-56 V-Flex System Alarms

UAM Text UAM Text
Critical Normal
0551 V-Flex Subsystem is not available 0554 VFLEX Subsystem is available
0555 VFLEX Subsystem is removed
0552 VFLEX Subsystem is disabled 0554 VFLEX Subsystem is available
0555 VFLEX Subsystem is removed
Major Normal
0556 V-Flex Subsystem degraded, card(s) abnormal 0554 VFLEX Subsystem is available
0555 VFLEX Subsystem is removed
Minor Normal
0553 VFLX Subsystem normal, card(s) abnormal 0554 VFLEX Subsystem is available
0555 VFLEX Subsystem is removed

A.57 X-LIST Alarms

X-LIST Alarms shows the major and minor X-LIST alarms and the clearing alarm that appears when each condition is resolved.

Table A-57 X-LIST Alarms

UAM Text UAM Text
Major Normal
0338 X-LIST space full-entry(s) discarded 0339 X-LIST space full condition abated
Minor Normal
0321 X-LIST occupancy threshold exceeded 0322 X-List occupancy below threshold