C Auto-Inhibit Hardware Verification Codes
This appendix provides a list of the auto-inhibit hardware verification codes used in the card device format.
C.1 Hardware Verification Codes in UAMs
Table C-1 contains a list of the hardware verification codes that appear in certain UAMs and shows the card or application that it applies to, a description of the code, and the UAM code with which it is associated.
Table C-1 Auto-Inhibit Hardware Verification Codes
HW Verification Code | Card or Application Code | Description | Associated UAM Code |
---|---|---|---|
058 | SS7IPGW, IPGWI, IPLIM, IPLIMI |
E5-ENET or E5-ENET-B does not support > 16 associations (IPLIMx). E5-ENET or E5-ENET-B does not support > 50 associations (IPGWx). |
422 |
059 | VSCCP | MPS database has been detected to exceed capacity of Service Module extended memory (only for GPORT, GFLEX, INP, EIR features). UAMs 281, 283, and 285 are used for LNP and LNP ELAP Configuration features. | 422 |
090 | Various | Flash image on the card is incompatible with the current release of EAGLE. | 570 |
099 | E5-TSM | E5-TSM card equipped has one or more daughterboard. | 99 |
101 | SS7IPGW, IPGWI, IPLIM, IPLIMI | E5-ENET only supports SLK link A-7 and B-7. | 276 |
102* | SS7IPGW, IPGWI | Non-DCM detected in slot. | 99 |
103 | SS7IPGW, IPGWI, IPLIM, IPLIMI |
E5-ENET or E5-ENET-B does not support >16 associations (IPLIMx). E5-ENET or E5-ENET-B does not support >50 associations (IPGWx). |
276 |
104 | SS7IPGW, IPGWI, IPLIM, IPLIMI |
E5-ENET or E5-ENET-B does not support >0 sockets (IPLIMx). E5-ENET or E5-ENET-B does not support >0 sockets (IPGWx). |
276 |
105 | SS7IPGW, IPGWI, IPLIM, IPLIMI |
E5-ENET or E5-ENET-B does not support > 0 (sockets + associations) (IPLIMx). E5-ENET or E5-ENET-B does not support > 50 (sockets + associations) (IPGWx). |
276 |
106 | SS7IPGW, IPGWI, IPLIM, IPLIMI |
E5-ENET or E5-ENET-B does not support >3200Kb SCTP buffers (IPLIMx). E5-ENET or E5-ENET-B does not support >3200Kb SCTP buffers (IPGWx). |
276 |
124 | HC-MIM | Card is not an HC-MIM and is provisioned as a T1 card. | 99 |
129 | HC-MIM, E5-E1T1 | Card does not support CAS framing. | 297 |
132 | IPLIM, IPLIMI, HC-MIM, E5-E1T1 | The actual card in the slot must be a HC-MIM, high capacity MIM or LIME1 if card is provisioned as a LIME1 card. | 99 |
133 | HC-MIM, E5-E1T1 | The actual card in the slot must be a high capacity MIM card (either HC-MIM or E5-E1T1) if provisioned with any un-channelized T1 ports. | 99 |
134 | E5-E1T1 | E5-E1T1 card with SLK provisioned on link greater than 15. | 99 |
135 | E5-E1T1 | E5-E1T1 card supports only 1 SE-HSL link. | 276 |
136 | E5-ATM, E5-ATM-B | E5-ATM card port B is provisioned. | 297 |
137 | E5-E1T1-B | E5-E1T1-B card with SLK provisioned with more than 64 links. | 297 |
138 | E5-E1T1-B | Only 2 high speed links are allowed on an E5-E1T1-B. | 99 |
140 | MCPHC | MCP card not running with D2G memory. | 422 |
141 | IPS | E5-IPSM card not running with D2G memory. | 422 |
142 | MCP | E5-MCPM-B card not running with D4G memory. | 422 |
150 | various | Card is obsolete. | 47 |
165 | VSCCP | Hardware configuration does not support configured feature set. | 99 |
170 | EROUTE | Non-E5-ENET/E5-ENET-B card detected in slot provisioned for eroute with card type STC. | 99 |
172 | E5-ENET-B card with IPSG |
An EPM-A based card has been detected ina lot provisioned for EPM-B based card, so the card will be auto-inhibited and issue a degraded mode alarm. To permit an E5-ENET to be allowed in a card slot provisioned for E5-ENET-B and to clear the alarm, a chg-card command will be required to change the card type from enetb to enet, or the E5-ENET card will need to be removed from the slot. Non-SLIC card detected in slot provisioned for IPSG and card type is SLIC with data=gtt. |
99 |
174 | IPSG | SLIC hardware detected having 32-bit flash GPL (BLSLC32) in a slot provisioned for IPSG and card type is SLIC with data=gtt. | 99 |
179 | E5-ATM-B, E5-ENET-B, E5-E1T1-B |
EPM-B based card detected and MFC is OFF. MFC option needs to be set to ON in STPOPTS before allowing the EPM-B based card. Note that the ON/OFF format is being used. For example, at least one MFC option needs to be set to ON in STPOPTS before allowing an E5-ENET-B card. The various option values that support MFC are STPOPTS:ON={mtplti, mtprsi, mtplprst, uimrd, critalminh, dispactalms, rptlnpmrss, rstrdev, cnvcgda, cnvcgdi, cnvcgdn, cnvcgdn24, gtcnvdflt, ansigflex, archbldid, mfc, cnvcgdn16}. Note: This code is specific to cards that do not support TVG. |
99 |
180 | DEIR, ENUM, SIP | If ports C and D are configured, the card location must be populated with SLIC cards only. | 441 |
180 |
SS7ANSI
SCCP |
SS7ANSI card provisioned as type LIME1 with MOBR on. -or- A non-SLIC card inserted in GTT-enabled IPSG card's location. -or- E5-SM8G-B card inserted in SM card location when EPAPX option is enabled. |
441 |
182 | OAM/IPS/MCP card | CARD running outdated Flash GPL | 225 |