5.22 dlt-bp
Use this command to delete breakpoints in the communication or application processors.
Parameters
- card (optional)
- The card location in the form of GPLID–Subsystem ID.
- Range:
- GPLID-Substystem ID
GPLID— atmhc, deirhc, erthc, glshc, hipr2, ipghc, iplhc, ipsg, ipshc, mcphc, oamhc, pktgen, sccphc, siphc, ss7hc, utility
Subsystem ID— a, b, act, stb, all
The OAMHC GPL can be specified with any of the subsystem IDs. For all other GPLs, only the all subsystem ID is valid.
- loc (optional)
- The card location as stenciled on the shelf of the system.
- Range:
- 1101 - 1108, 1111 - 1112, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118, 1109, 1110, 1209, 1210, 1309, 1310, 2109, 2110, 2209, 2210, 2309, 2310, 3109, 3110, 3209, 3210, 3309, 3310, 4109, 4110, 4209, 4210, 4309, 4310, 5109, 5110, 5209, 5210, 5309, 5310, 6109, 6110, 1113, 1115
Example
dlt-bp:loc=1209:ueng=2
dlt-bp:card=hipr2-all
dlt-bp:loc=6312
Dependencies
The loc, imt, or card parameter must be specified.
2214 E2214 Cmd Rej: Missing parameter - CARD, LOC, or IMT
Only one of the loc, imt, and card parameters can be specified in the command.
2217 E2217 Cmd Rej: More than one of CARD, LOC, and IMT specified
The ueng parameter can be specified only for IXP-based cards.
4151 E4151 Cmd Rej: UENG parameter is invalid for this card
The card location specified by the loc parameter must be in the database.
2101 E2101 Cmd Rej: Card location is unequipped
Values of 1114, 1116, 1117, and 1118 cannot be specified for the loc parameter.
2212 E2212 Cmd Rej: Invalid card type for this command
All of the subsystem values can be specified with the oamhc GPLID. The other GPLID values can be specified only with the all subsystem value.
2208 E2208 Cmd Rej: ALL only qualifier allowed with given card type
The addr and paddr parameters cannot be specified together in the command.
2694 E2694 Cmd Rej: Invalid combination of ADDR and PADDR specified
Notes
The imt parameter allows this command to be entered for a card that has not been configured in the system.
Output
dlt-bp:card=oam-all:proc=com
Command Accepted - Processing
tekelecstp 97-01-20 19:21:10 EST Rel 37.0.0
dlt-bp:card=oam-all:proc=com
Command entered at terminal #1.
;