5.22 dlt-bp

Use this command to delete breakpoints in the communication or application processors.

Parameters

addr (optional)
The address in the form of segment–offset.
Range:
segment-offset

segment h’00–h’ffff

offset h’00–h’ffff

card (optional)
The card location in the form of GPLID–Subsystem ID.
Range:
GPLID-Substystem ID

GPLIDatmhc, deirhc, erthc, glshc, hipr2, ipghc, iplhc, ipsg, ipshc, mcphc, oamhc, pktgen, sccphc, siphc, ss7hc, utility

Subsystem ID a, b, act, stb, all

The OAMHC GPL can be specified with any of the subsystem IDs. For all other GPLs, only the all subsystem ID is valid.

imt (optional)
The IMT address of the card.
Range:
0 - 254
loc (optional)
The card location as stenciled on the shelf of the system.
Range:
1101 - 1108, 1111 - 1112, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118, 1109, 1110, 1209, 1210, 1309, 1310, 2109, 2110, 2209, 2210, 2309, 2310, 3109, 3110, 3209, 3210, 3309, 3310, 4109, 4110, 4209, 4210, 4309, 4310, 5109, 5110, 5209, 5210, 5309, 5310, 6109, 6110, 1113, 1115
paddr (optional)
The physical offset of the memory address.
Range:
h’00–h’ffffffff
proc (optional)
The processor type.
Range:
appl
Application processor
com
Communication processor
Default:
appl
ueng (optional)
The microengine number.

Note:

This parameter is valid only on IXP-based cards. If this parameter is not specified for IXP-based cards, then the command is assumed to be intended for the ARM processor in the IXP chip.
Range:
0 - 5

Example

dlt-bp:loc=1209:ueng=2

dlt-bp:card=hipr2-all

dlt-bp:loc=6312

Dependencies

The loc, imt, or card parameter must be specified.

2214 E2214 Cmd Rej: Missing parameter - CARD, LOC, or IMT

Only one of the loc, imt, and card parameters can be specified in the command.

2217 E2217 Cmd Rej: More than one of CARD, LOC, and IMT specified

The ueng parameter can be specified only for IXP-based cards.

4151 E4151 Cmd Rej: UENG parameter is invalid for this card

The card location specified by the loc parameter must be in the database.

2101 E2101 Cmd Rej: Card location is unequipped

Values of 1114, 1116, 1117, and 1118 cannot be specified for the loc parameter.

2212 E2212 Cmd Rej: Invalid card type for this command

All of the subsystem values can be specified with the oamhc GPLID. The other GPLID values can be specified only with the all subsystem value.

2208 E2208 Cmd Rej: ALL only qualifier allowed with given card type

The addr and paddr parameters cannot be specified together in the command.

2694 E2694 Cmd Rej: Invalid combination of ADDR and PADDR specified

Notes

The imt parameter allows this command to be entered for a card that has not been configured in the system.

Output

dlt-bp:card=oam-all:proc=com

    Command Accepted - Processing

    tekelecstp 97-01-20 19:21:10 EST Rel 37.0.0
    dlt-bp:card=oam-all:proc=com
    Command entered at terminal #1. 
;

Related Topics