27 Replacement Units
This appendix lists the replacement units for Recovery Appliance. It contains the following topics:
About Warranty Coverage
All replaceable parts are field replaceable units (FRUs) under the Oracle Premier Support for Systems warranty. Oracle field engineers install the replacement parts.
Understanding Repair Categories
Repair categories describe the potential impact of a repair action. Table 27-1 describes the categories and actions.
Table 27-1 Recovery Appliance Repair Categories
Category | Description | Examples |
---|---|---|
Hot Swap (HS) |
Repair part is hot swappable, and can be replaced without shutting down the host system. Commands might be required before and after replacement to protect data. |
|
Infrastructure Repair (IR) |
Repairing a connectivity component within the Recovery Appliance rack. No downtime of the rack is required; however, individual components may require downtime. |
|
Compute Server Offline (DBO) |
Repairing the part requires shutting down a compute server. No downtime of the rack is required; however, individual servers might require downtime, and they might be taken outside of the cluster temporarily. If the server is currently running, then you must shut it down. See "Powering Down the Servers". If you monitor the system using Oracle Enterprise Manager Grid Control, then avoid unnecessary alerts by putting the target in a blackout state. Refer to Oracle Enterprise Manager Administration for additional information. |
|
Storage server Offline (EBO) |
Repairing the part requires shutting down a storage server within the rack. No downtime of the rack is required; however, individual servers might require downtime, and they might be taken outside of the cluster temporarily. There also might be a temporary performance impact, while the system rebalances to maintain data redundancy. If the server is currently running, then you must shut it down. See "Powering Down the Servers". If you monitor the system using Oracle Enterprise Manager Grid Control, then avoid unnecessary alerts by putting the target in a blackout state. Refer to Oracle Enterprise Manager Administration for additional information. |
|
LED Status Descriptions
Oracle Server LEDs
Table 27-2 identifies the LED status indicators that can indicate faults on the compute servers and the storage servers.
Table 27-2 Oracle Server LED Status Descriptions
See Also:
-
"About Server and Component Status Indicators" in the Sun Server X4-2 Service Manual at
http://docs.oracle.com/cd/E36975_01/html/E38045/z4000be71405942.html#scrolltoc
-
"About Server and Component Status Indicators" in the Sun Server X4-2L Service Manual at
http://docs.oracle.com/cd/E36974_01/html/E38145/z40003ec1405942.html#scrolltoc
Sun Datacenter InfiniBand Switch 36 LEDs
Table 27-3 identifies the LED status indicators that can indicate faults on Sun Datacenter InfiniBand Switch 36.
Table 27-3 Sun InfiniBand Switch LED Status Descriptions
See Also:
"Identifying LEDs" in the Sun Datacenter InfiniBand Switch 36 Service Manual at
http://docs.oracle.com/cd/E26698_01/html/E26434/z40000fe1394411.html
Parts for Compute Servers
The following topics identify the replacement parts for the Recovery Appliance compute servers:
Database Server Components of Recovery Appliance X9M-2
Each Recovery Appliance X9M-2 database server includes the following components:
- CPU - 32-core Intel Xeon 8358 processors (2.6 GHz):
- Flexible configuration: 2 CPUs
- Eighth Rack: 1 CPU
- RAM:
- Flexible configuration: 512 GB RAM (16 x 32 GB DIMMs), expandable to 1 TB (16 x 64 GB DIMMs), 1.5 TB (16 x 32 GB and 16 x 64 GB DIMMs), or 2 TB (32 x 64 GB DIMMs) with memory expansion kit
- Eighth Rack: 384 GB RAM (12 x 32 GB DIMMs), expandable to 1 TB (16 x 64 GB DIMMs) with memory expansion kit
- System storage: 2 x 3.84 TB PCIe 4.0 NVMe storage drives, expandable to 4 drives
- RDMA Network Fabric: 1 x dual-port CX5 RDMA Network Fabric card; PCIe 4.0, 2 x 100 Gb/s ports active-active (200 Gb/s combined throughput)
- Administration network: 1 x 1 GbE Base-T Ethernet port
- Integrated Lights Out Manager (ILOM) port for remote management: 1 x 1 GbE Base-T Ethernet port
- Client and additional network connectivity:
- Flexible configuration options:
- Two factory-installed network cards. Each card contains 2 x SFP+/SFP28 ports (10/25 GbE) or 4 x 10GBASE-T ports (10 GbE)
- One optional field-installed network card containing 2 x SFP+/SFP28 ports (10/25 GbE) or 4 x 10GBASE-T ports (10 GbE) or 2 x QSFP28 ports (100GbE). Each QSFP28 port can support one 10 GbE or 25 GbE link with appropriate breakout cables.
- Eighth Rack: Two factory-installed network cards only. Each card contains 2 x SFP+/SFP28 ports (10/25 GbE) or 4 x 10GBASE-T ports (10 GbE)
- Flexible configuration options:
Database Server Components of Recovery Appliance X8M-2
Recovery Appliance X8M-2 database servers include the following components:
- 2 x 24-core Intel Xeon Platinum 8260 Processors (2.4 GHz)
- 384 GB RAM (12 x 32 GB DIMMs), expandable to 1.5 TB (24 x 64 GB DIMMs) with memory expansion kit
- 4 x 1.2 TB boot drive/hard disks, hot swappable, expandable to 8 drives
- Disk controller HBA with 2 GB cache (no batteries)
- RDMA Network Fabric: 1 x dual-port QSFP28 100 Gb/s PCIe 3.0 RDMA Network Fabric card - both ports active
- Client network: 2 x SFP+/SFP28 ports (10/25 GbE) or 2 x 10GBASE-T ports (10 GbE)
- Backup/optional networks: 2 x SFP+/SFP28 ports (10/25 GbE) or 4 x 10GBASE-T ports (10 GbE)
- Administration network: 1 x 1 GbE Base-T Ethernet port
- Integrated Lights Out Manager (ILOM) port for remote management: 1 x 1 GbE Base-T Ethernet port
Oracle Server X8-2 and X8M-2 Database Server Parts
The following image shows the front view of Oracle Server X8-2 and X8M-2 Database Servers.
Figure 27-1 Front View of Oracle Server X8-2 and X8M-2 Database Servers

Description of "Figure 27-1 Front View of Oracle Server X8-2 and X8M-2 Database Servers"
The following image shows the rear view of the Oracle Server.
Figure 27-2 Rear View of Oracle Server X8-2 and X8M-2 Database Servers

Description of "Figure 27-2 Rear View of Oracle Server X8-2 and X8M-2 Database Servers"
The following table lists the replaceable parts for Oracle Server X8-2 and X8M-2 database servers. Refer to this table only if you have a basic warranty. All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.
Table 27-4 Replacement Parts for Oracle Server X8-2 and X8M-2 Database Servers
Part Number | Description | Repair Category | Coverage under Basic Warranty | Repair Procedure |
---|---|---|---|---|
370-5621-01 |
3 volt lithium battery grover |
DBO |
FRU |
See "Servicing the Battery (CRU)" in Oracle Exadata X8-2 Database Server Service Manual at |
7363537 |
ASSY DRV 1.2TB 10KRPM SAS3 512N SFF MARLIN |
DBO |
FRU |
See "Servicing Storage Drives (CRU)" in Oracle Exadata X8-2 Database Server Service Manual at |
7322171 |
ASM LFIM |
DBO |
FRU |
See "Servicing Other Cables (FRU)" in Oracle Exadata X8-2 Database Server Service Manual at |
7339763 |
BD LP DUAL SFP28 ADAPTER WHITNEY+ PCIe3.0x8 |
DBO |
CRU |
|
8200663 |
HEATSINK CPU HEIGHT:23.5 MM |
DBO |
FRU |
See "Servicing Processors (FRU)" in Oracle Exadata X8-2 Database Server Service Manual at |
7343599 |
Assembly, riser, 1-slot, 1U |
DBO |
FRU |
See "Servicing PCIe Risers (CRU)" in Oracle Exadata X8-2 Database Server Service Manual at |
7330698 |
DIMM, 32 GB, RDIMM, DDR4, 2666 2Rx4 1.2V |
DBO |
CRU |
See "Servicing the DIMMs (CRU)" in Oracle Exadata
X8-2 Database Server Service Manual at |
8200116 |
Power supply, AC, A266, F, 12V, 1200W |
HS |
CRU |
|
7332895 |
HBA, 12 Gb SAS PCIe 16-port RAID internal with flash module |
DBO |
FRU |
See "Servicing the Internal HBA Card and HBA Super Capacitor (FRU)" in Oracle Exadata X8-2 Database Server Service Manual at |
7086345 |
Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA |
DBO |
FRU |
See "Servicing the Internal HBA Card and HBA Super Capacitor (FRU)" in Oracle Exadata X8-2 Database Server Service Manual at |
7340897 |
Cable, SAS3 to HBA |
DBO |
CRU |
See "Servicing the Internal HBA Cables" in Oracle Exadata X8-2 Database Server Service Manual at |
7331123 |
Assembly, fan module |
HS |
CRU |
See "Servicing Fan Modules (CRU)" in Oracle Exadata X8-2 Database Server Service Manual at |
8200428 |
CPU INTEL CLX P8260 (B1) 2.4 GHz 165W 24c 8S 1TB (S-RF9H) |
DBO |
FRU |
See "Servicing Processors (FRU)" in Oracle Exadata X8-2 Database Server Service Manual at |
7104073 |
Assembly, Dual 40Gb/Sec (4x) QDR RDMA Fabric Host Channel Adapter Module M3 |
DBO |
CRU |
|
7046442 (X8-2) |
Assembly, Dual port, QDR CX3, HCA |
DBO |
CRU |
|
7119792 (X8M-2) |
CX5 100GbE Adapter Dual Port QSFP28 |
DBO |
CRU |
|
7360829 |
Assembly, motherboard, 1U |
DBO |
FRU |
|
7331100 |
Assembly, riser, 2-slot, 1U |
DBO |
FRU |
See "Servicing PCIe Risers (CRU)" in Oracle Exadata X8-2 Database Server Service Manual at |
7331142 |
Assembly, Front LED indicator module |
DBO |
FRU |
See "Servicing the Front LED Indicator Module (FRU)" in Oracle Exadata X8-2 Database Server Service Manual at |
Parts for Storage Servers
The following topics identify the replacement parts for the Recovery Appliance storage servers:
Oracle Exadata Storage Server X9M-2, X8M-2, and X8-2 High Capacity and Extended (XT) Server Parts
The following figure shows the front view of the Oracle Exadata Storage Server X9M-2, X8M-2 and X8-2 High Capacity and XT servers.
Note:
The Recovery Appliance supports Oracle Exadata Storage Server high capacity servers and does not use Oracle Exadata Storage Server XT servers. Both are discussed for completeness and compatibility with Oracle Exadata documentation.Figure 27-3 Front View of Oracle Exadata Storage Server X9M-2, X8M-2 and X8-2 High Capacity and XT servers

Description of "Figure 27-3 Front View of Oracle Exadata Storage Server X9M-2, X8M-2 and X8-2 High Capacity and XT servers "
The following figure shows the rear view of the Oracle Exadata Storage Server X8M-2 and X8-2 High Capacity and XT servers.
Note:
The Recovery Appliance does not support XT servers.Figure 27-4 Rear View of Oracle Exadata Storage Server X9M-2, X8M-2 and X8-2 High Capacity and XT servers

Description of "Figure 27-4 Rear View of Oracle Exadata Storage Server X9M-2, X8M-2 and X8-2 High Capacity and XT servers "
The following table lists the replaceable parts for Oracle Exadata Storage Server X9M-2, X8M-2 and X8-2 High Capacity and XT servers. Refer to this table only if you have a basic warranty. All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.
Note:
The Recovery Appliance supports Oracle Exadata Storage Server high capacity servers and does not use Oracle Exadata Storage Server XT servers. Both are discussed for completeness and compatibility with Oracle Exadata.Table 27-5 Replacement Parts for Oracle Exadata Storage Server X8M-2 and X8-2 High Capacity and XT Servers
Part Number | Description | Repair Category | Coverage under Basic Warranty | Repair Procedure |
---|---|---|---|---|
370-5621-01 |
3 volt lithium battery grover |
EBO |
FRU |
See "Servicing the Battery" in Oracle Exadata
Storage Server X8-2 EF, HC, and XT Service Manual at |
7322171 |
Assembly, Front LED Indicator Module (LFIM) |
EBO |
FRU |
See "Servicing the Front LED Indicator Module" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at
|
7341141 |
Assembly, 12-slot disk backplane |
EBO |
FRU |
See "Servicing the Disk Backplane" in Oracle
Exadata Storage Server X8-2 EF, HC, and XT Service Manual at
|
8200116 |
Power Supply, A266 F, 1200W, AC Input |
HS |
FRU |
|
7322166 |
Fan assembly, 2U |
HS |
FRU |
See "Servicing Fan Modules" in Oracle Exadata
Storage Server X8-2 EF, HC, and XT Service Manual at |
7046442 (X8-2) |
Assembly, dual port, QDR CX3, Host Channel Adapter |
EBO |
FRU |
|
7119792 (X8M-8) |
CX5 100GbE Adapter Dual Port QSFP28 |
DBO | CRU |
|
7322160 |
Heat sink, CPU |
EBO |
FRU |
See "Servicing Processors" in Oracle Exadata
Storage Server X8-2 EF, HC, and XT Service Manual at |
7357761 |
Assembly, Drive, 14TB 3.5" SAS3/7200 rpm Coral with encryption |
HS |
FRU |
See "Servicing Storage Drives" in Oracle Exadata
Storage Server X8-2 EF, HC, and XT Service Manual at |
7353916 |
RDIMM 16GB, DDR4 2666, 1Rx4 1.2V |
EBO |
FRU |
See "Servicing the DIMMs" in Oracle Exadata Storage
Server X8-2 EF, HC, and XT Service Manual at |
7332895 |
HBA, 12 Gbps SAS PCIe 16-port internal RAID with flash module |
EBO |
FRU |
See "Servicing the Internal HBA Card and HBA Super Capacitor" in
Oracle Exadata Storage Server X8-2 EF, HC, and XT Service
Manual at |
7086345 |
Assembly, super cap, 13.5V, 6.4F, SAS3 HBA |
EBO |
FRU |
See "Servicing the Internal HBA Card and HBA Super Capacitor" in
Oracle Exadata Storage Server X8-2 EF, HC, and XT Service
Manual at |
7315464 |
SAS-3 Data Cable Assembly |
EBO |
FRU |
See "Servicing SAS Cables" in Oracle Exadata
Storage Server X8-2 EF, HC, and XT Service Manual at |
7361253 |
M.2,240GB,SATA,22x80mm,SSD,INTEL, DC S4510 |
EBO |
FRU |
See "Servicing the Internal M.2 Flash SSDs" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at
|
7335943 |
6.4TB FLASH F640 NVMe AIC AURA 7 |
EBO |
FRU |
See "Servicing PCIe Cards" in Oracle Exadata
Storage Server X8-2 EF, HC, and XT Service Manual at |
7361454 |
6.4TB FLASH F640 V2 NVMe AIC AURA 8 |
EBO |
FRU |
See "Servicing PCIe Cards" in Oracle Exadata
Storage Server X8-2 EF, HC, and XT Service Manual at |
8200426 |
CPU INTEL CLX G5218 (B1) 2.3 GHz 125W 16c 4S 1TB (S-RF8T) |
EBO |
FRU |
See "Servicing Processors" in Oracle Exadata
Storage Server X8-2 EF, HC, and XT Service Manual at |
7360978 |
Assembly, System board |
EBO |
FRU |
See "Servicing the Motherboard Assembly" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at
|
7341466 |
Assembly, M.2 form factor riser |
EBO |
FRU |
See "Servicing the Internal M.2 Flash SSDs" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at
http://docs.oracle.com/cd/E93361_01/html/E93395/grlly.html#scrolltoc |
Parts for Cisco Switch
Table 27-6 lists replaceable parts for the Cisco switch used with Recovery Appliance.
Note:
All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.
Table 27-6 Replacement Parts for Cisco Switch
Part Number | Description | Repair Category | Repair |
---|---|---|---|
7023685 |
Cisco Catalyst 4948 switch, RoHS:Y |
IR |
See chapter 3 in Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
7024423 |
Power supply for Cisco Catalyst 4948 switch, RoHS:Y |
HS |
See chapter 4 in Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
7024424 |
Cooling fan for Cisco Catalyst 4948 switch, RoHS:Y |
HS |
See chapter 4 in Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
Parts for InfiniBand Switches
Table 27-7 lists the replaceable parts for the InfiniBand switches used in Recovery Appliance. See "Cables and Cable Accessories for Recovery Appliance" for information about InfiniBand cables.
Note:
All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.
Table 27-7 Replacement Parts for InfiniBand Switches
Part Number | Description | Repair Category | Repair |
---|---|---|---|
300-2143 |
760 watt power supply, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
300-2299 |
760 watt AC input power supply |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
350-1312 |
Fan module for Sun Datacenter InfiniBand Switch 36, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
350-1566 |
Fan module, 1 RU, Sanace, reverse |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
371-2210 |
CR2032 3 v battery, RoHS:Y |
IR |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
541-3495 |
Sun Datacenter InfiniBand Switch 36, RoHS:YL |
IR |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
7052970 |
Sun Datacenter InfiniBand Switch 36, RoHS:YL |
IR |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
7061031 |
Fan module, 1 RU, Sanace, reverse |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
Parts for Power Distribution Units
Table 27-8 lists the replacement parts for the power distribution units (PDUs). Given the number of cables and connections, Oracle recommends that you shut down the Recovery Appliance rack when replacing power distribution unit parts.
Note:
All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.
Table 27-8 Replacement Parts for Power Distribution Units
Part Number | Description | Repair Category | Repair |
---|---|---|---|
180-2379 |
13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 1 meter, RoHS:Y |
HS |
Not applicable |
180-2380 |
13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 2 meter, RoHS:Y |
HS |
Not applicable |
371-4000 |
Three-phase PDU: 15kV,5-Pin, IEC309 32A, 5 PIN 230/400V, 3ph IP44, International, RoHS:Y |
IR |
See "Replacing a Power Distribution Unit" of this guide. |
371-4199 |
Single-phase PDU: 15kVA, with three 30A/250V 2-Pole/3-Wire NEMA L6-30P Plugs, North America, RoHS:Y |
IR |
See "Replacing a Power Distribution Unit" of this guide. |
371-4201 |
Single-phase PDU: 15kVA, with three Blue 32A/240V Splash-proof 2-Pole/3-Wire IEC 60309 Plugs, International, RoHS:Y |
IR |
See "Replacing a Power Distribution Unit" of this guide. |
371-5039 |
Single-phase PDU: 22k VA Hubbell CS8265C PlugNo X-Option |
IR |
See "Replacing a Power Distribution Unit" of this guide. |
371-5040 |
Single-phase PDU: 22k VA Blue 32A IEC 60309 Plug No X-Option |
IR |
See "Replacing a Power Distribution Unit" of this guide. |
7051908 |
Three-phase PDU: 15kVA, IEC309 60A, 4 PIN, 250VAC, 3ph IP67, North America, RoHS:Y |
IR |
See "Replacing a Power Distribution Unit" of this guide. |
Cables and Cable Accessories for Recovery Appliance
Table 27-9 lists the replacement cables and cable accessories for Recovery Appliance.
Note:
All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.
Table 27-9 Replacement Cables for Recovery Appliance
Part Number | Description | Repair Category | Repair |
---|---|---|---|
350-1287 |
Slim rail, CMA, 1U-2U for a storage server |
EBO |
|
350-1546 |
Cable management arm (CMA) 1U, RoHS:Y for compute server |
DBO |
|
350-1519 |
Serial cable kit, RoHS:Y with the following:
|
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
350-1637 |
Label assembly, EV2, 2-way, upgrade, label |
HS |
|
350-1638 |
Label assembly EV2, 3-way, service upgrade, label |
HS |
|
350-1639 |
Label assembly EV2, 4-way, service upgrade, label |
HS |
|
350-1640 |
Label assembly EV2, 5-way, service upgrade, label |
HS |
|
350-1641 |
Label assembly EV2, 6-way, service upgrade, label |
HS |
|
350-1642 |
Label assembly EV2, 7-way, service upgrade, label |
HS |
|
350-1643 |
Label assembly EV2, 8-way, service upgrade, label |
HS |
|
530-4445 |
QSFP InfiniBand passive copper cable, 10 GbE, 3 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
Note: There is a loss of redundancy when replacing cables. |
530-4446 |
QSFP InfiniBand passive copper cable, 10 GbE, 5 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
Note: There is a loss of redundancy when replacing cables. |
530-4403 |
4x QSFP copper QDR InfiniBand cable, 2 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
Note: There is a loss of redundancy when replacing cables. |
530-4404 |
4x QSFP copper QDR InfiniBand cable, 3 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
530-4415 |
4x QSFP copper QDR InfiniBand cable, 5 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
530-4432 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, blue, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4433 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, red, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4434 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, red, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4435 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, black, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4436 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, black, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4437 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, orange, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4438 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, black, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4444 |
QSFP to QSFP Passive Copper Cable, 1 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
530-4445 |
QSFP passive copper cable, 10 GE, 3 m |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
530-4502-01 |
Ethernet cable, Cat 5/5E, 10 foot, blue, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
7015400 |
Power cable, jumper, SR2, 2m C14RA, 10A, C13 |
HS |
See "Replacing a Power Distribution Unit" of this guide. |
7042273 |
Slim rail, cable management arm, 1U-2U for a storage server |
EBO |
|
7102869 |
Passive fiber InfiniBand cable, 10 m, RoHS:Y |
HS |
Note: Purchase two QSFP SR Transceivers (Part Number X2124A-N) for each passive fiber cable. |
7102870 |
Passive fiber InfiniBand cable, 20 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
Note: Purchase two QSFP SR Transceivers (Part Number X2124A-N) for each passive fiber cable. |
7102871 |
Passive fiber InfiniBand cable, 50 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
Note: Purchase two QSFP SR Transceivers (Part Number X2124A-N) for each passive fiber cable. |