18.2 Sun Integrated Lights Out Manager Cabling Tables
The following tables are in this section:
-
Table 18-1 ILOM Cabling for Oracle Exadata Database Machine X6-2 and X5-2 Full Rack
-
Table 18-2 ILOM Cabling for Oracle Exadata Database Machine X6-2 and X5-2 Half Rack
-
Table 18-3 ILOM Cabling for Oracle Exadata Database Machine X6-2 and X5-2 Quarter Rack
-
Table 18-4 ILOM Cabling for Oracle Exadata Database Machine X5-8 and X6-8 Full Rack
The following table shows the cable connections from the servers to the ILOM switch in Oracle Exadata Database Machine X6-2 and X5-2 Full Rack:
Table 18-1 ILOM Cabling for Oracle Exadata Database Machine X6-2 and X5-2 Full Rack
From Rack Unit | Type of Equipment | Gigabit Ethernet Port |
---|---|---|
U39 |
Exadata Storage Server |
2 |
U37 |
Exadata Storage Server |
4 |
U35 |
Exadata Storage Server |
6 |
U33 |
Exadata Storage Server |
8 |
U31 |
Exadata Storage Server |
10 |
U29 |
Exadata Storage Server |
12 |
U27 |
Exadata Storage Server |
14 |
U26 |
Database server |
16 |
U25 |
Database server |
18 |
U24 |
Database server |
20 |
U23 |
Database server |
22 |
U19 |
Database server |
24 |
U18 |
Database server |
26 |
U17 |
Database server |
28 |
U16 |
Database server |
30 |
U14 |
Exadata Storage Server |
32 |
U12 |
Exadata Storage Server |
34 |
U10 |
Exadata Storage Server |
36 |
U8 |
Exadata Storage Server |
38 |
U6 |
Exadata Storage Server |
40 |
U4 |
Exadata Storage Server |
42 |
U2 |
Exadata Storage Server |
44 |
The following table shows the cable connections from the servers to the ILOM switch in Oracle Exadata Database Machine X6-2 and X5-2 Half Rack:
Table 18-2 ILOM Cabling for Oracle Exadata Database Machine X6-2 and X5-2 Half Rack
From Rack Unit | Type of Equipment | Gigabit Ethernet Port |
---|---|---|
U19 |
Database server |
24 |
U18 |
Database server |
26 |
U17 |
Database server |
28 |
U16 |
Database server |
30 |
U14 |
Exadata Storage Server |
32 |
U12 |
Exadata Storage Server |
34 |
U10 |
Exadata Storage Server |
36 |
U8 |
Exadata Storage Server |
38 |
U6 |
Exadata Storage Server |
40 |
U4 |
Exadata Storage Server |
42 |
U2 |
Exadata Storage Server |
44 |
The following table shows the cable connections from the servers to the ILOM switch in Oracle Exadata Database Machine X6-2 and X5-2 Quarter Rack:
Table 18-3 ILOM Cabling for Oracle Exadata Database Machine X6-2 and X5-2 Quarter Rack
From Rack Unit | Type of Equipment | Gigabit Ethernet Port |
---|---|---|
U17 |
Database server |
28 |
U16 |
Database server |
30 |
U6 |
Exadata Storage Server |
40 |
U4 |
Exadata Storage Server |
42 |
U2 |
Exadata Storage Server |
44 |
The following table shows the cable connections from the servers to the ILOM switch in Oracle Exadata Database Machine X5-8 and X6-8 Full Rack:
Table 18-4 ILOM Cabling for Oracle Exadata Database Machine X5-8 and X6-8 Full Rack
From Rack Unit | Type of Equipment | Gigabit Ethernet Port |
---|---|---|
U41 |
Exadata Storage Server |
2 |
U39 |
Exadata Storage Server |
4 |
U37 |
Exadata Storage Server |
6 |
U35 |
Exadata Storage Server |
8 |
U33 |
Exadata Storage Server |
10 |
U31 |
Exadata Storage Server |
12 |
U29 |
Exadata Storage Server |
14 |
U24 |
Database server |
16 |
U16 |
Database server |
18 |
U14 |
Exadata Storage Server |
20 |
U12 |
Exadata Storage Server |
22 |
U10 |
Exadata Storage Server |
24 |
U8 |
Exadata Storage Server |
26 |
U6 |
Exadata Storage Server |
28 |
U4 |
Exadata Storage Server |
30 |
U2 |
Exadata Storage Server |
32 |