20.6 InfiniBand Network Cabling Tables
This section contains the tables for the InfiniBand network cabling. The Sun Datacenter InfiniBand Switch 36 switches are located in located in rack unit 1, 20 and 22.
The following tables are in this section:
Table 20-17 lists the location, ports and cables for the InfiniBand connections for Oracle Exadata Database Machine X3-2 Full Rack.
Table 20-17 InfiniBand Network Cabling for Oracle Exadata Database Machine X3-2 Full Rack
From InfiniBand Switch Rack Unit | Port | To Rack Unit | Type of Equipment | Port | Cable Description |
---|---|---|---|---|---|
U22 |
0A |
U39 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U22 |
0B |
U37 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U22 |
1A |
U35 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U22 |
1B |
U33 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U22 |
2A |
U31 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U22 |
2B |
U29 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U22 |
3A |
U27 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U22 |
3B |
U26 |
Database server |
PCIe 3, P1 |
2 meter QDR InfiniBand cable |
U22 |
4A |
U25 |
Database server |
PCIe 3, P1 |
2 meter QDR InfiniBand cable |
U22 |
4B |
U24 |
Database server |
PCIe 3, P1 |
2 meter QDR InfiniBand cable |
U22 |
5A |
U23 |
Database server |
PCIe 3, P1 |
2 meter QDR InfiniBand cable |
U22 |
12B |
U19 |
Database server |
PCIe 3, P2 |
2 meter QDR InfiniBand cable |
U22 |
13A |
U18 |
Database server |
PCIe 3, P2 |
2 meter QDR InfiniBand cable |
U22 |
13B |
U17 |
Database server |
PCIe 3, P2 |
2 meter QDR InfiniBand cable |
U22 |
14A |
U16 |
Database server |
PCIe 3, P2 |
2 meter QDR InfiniBand cable |
U22 |
14B |
U14 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U22 |
15A |
U12 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U22 |
15B |
U10 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U22 |
16A |
U8 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U22 |
16B |
U6 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U22 |
17A |
U4 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U22 |
17B |
U2 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U20 |
0A |
U39 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U20 |
0B |
U37 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U20 |
1A |
U35 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U20 |
1B |
U33 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U20 |
2A |
U31 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U20 |
2B |
U29 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U20 |
3A |
U27 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U20 |
3B |
U26 |
Database server |
PCIe 3, P2 |
2 meter QDR InfiniBand cable |
U20 |
4A |
U25 |
Database server |
PCIe 3, P2 |
2 meter QDR InfiniBand cable |
U20 |
4B |
U24 |
Database server |
PCIe 3, P2 |
2 meter QDR InfiniBand cable |
U20 |
5A |
U23 |
Database server |
PCIe 3, P2 |
2 meter QDR InfiniBand cable |
U20 |
12B |
U19 |
Database Server |
PCIe 3, P1 |
2 meter QDR InfiniBand cable |
U20 |
13A |
U18 |
Database server |
PCIe 3, P1 |
2 meter QDR InfiniBand cable |
U20 |
13B |
U17 |
Database server |
PCIe 3, P1 |
2 meter QDR InfiniBand cable |
U20 |
14A |
U16 |
Database server |
PCIe 3, P1 |
2 meter QDR InfiniBand cable |
U20 |
14B |
U14 |
Exadata Storage Server |
PCIe 3, P1 |
2 meter QDR InfiniBand cable |
U20 |
15A |
U12 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U20 |
15B |
U10 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U20 |
16A |
U8 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U20 |
16B |
U6 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U20 |
17A |
U4 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U20 |
17B |
U2 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U22 |
8B |
U1 |
Sun Datacenter InfiniBand Switch 36 switch |
0B |
3 meter QDR InfiniBand cable |
U20 |
8B |
U1 |
Sun Datacenter InfiniBand Switch 36 switch |
1B |
3 meter QDR InfiniBand cable |
U20 |
9B |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
9A |
1 meter QDR InfiniBand cable |
U20 |
10B |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
10A |
1 meter QDR InfiniBand cable |
U20 |
11B |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
11A |
1 meter QDR InfiniBand cable |
U20 |
8A |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
8A |
1 meter QDR InfiniBand cable |
U20 |
9A |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
9B |
1 meter QDR InfiniBand cable |
U20 |
10A |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
10B |
1 meter QDR InfiniBand cable |
U20 |
11A |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
11B |
1 meter QDR InfiniBand cable |
U1 |
1B |
U20 |
Sun Datacenter InfiniBand Switch 36 switch |
8B |
3 meter QDR InfiniBand cable |
U1 |
0B |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
8B |
3 meter QDR InfiniBand cable |
Table 20-18 lists the location, ports and cables for the InfiniBand connections for Oracle Exadata Database Machine X3-2 Half Rack.
Note:
The Sun Datacenter InfiniBand Switch 36 switch in rack position U1 is included in Oracle Exadata Database Machine X3-2 Half Racks.
Table 20-18 InfiniBand Network Cabling for Oracle Exadata Database Machine X3-2 Half Rack
From InfiniBand Switch Rack Unit | Port | To Rack Unit | Type of Equipment | Port | Cable Description |
---|---|---|---|---|---|
U22 |
12B |
U19 |
Database server |
PCIe 3, P2 |
2 meter QDR InfiniBand cable |
U22 |
13A |
U18 |
Database server |
PCIe 3, P2 |
2 meter QDR InfiniBand cable |
U22 |
13B |
U17 |
Database server |
PCIe 3, P2 |
2 meter QDR InfiniBand cable |
U22 |
14A |
U16 |
Database server |
PCIe 3, P2 |
2 meter QDR InfiniBand cable |
U22 |
14B |
U14 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U22 |
15A |
U12 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U22 |
15B |
U10 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U22 |
16A |
U8 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U22 |
16B |
U6 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U22 |
17A |
U4 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U22 |
17B |
U2 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U20 |
12B |
U19 |
Database Server |
PCIe 3, P1 |
2 meter QDR InfiniBand cable |
U20 |
13A |
U18 |
Database server |
PCIe 3, P1 |
2 meter QDR InfiniBand cable |
U20 |
13B |
U17 |
Database server |
PCIe 3, P1 |
2 meter QDR InfiniBand cable |
U20 |
14A |
U16 |
Database server |
PCIe 3, P1 |
2 meter QDR InfiniBand cable |
U20 |
14B |
U14 |
Exadata Storage Server |
PCIe 3, P1 |
2 meter QDR InfiniBand cable |
U20 |
15A |
U12 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U20 |
15B |
U10 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U20 |
16A |
U8 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U20 |
16B |
U6 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U20 |
17A |
U4 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U20 |
17B |
U2 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U20 |
9B |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
9A |
1 meter QDR InfiniBand cable |
U20 |
10B |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
10A |
1 meter QDR InfiniBand cable |
U20 |
11B |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
11A |
1 meter QDR InfiniBand cable |
U20 |
8A |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
8A |
1 meter QDR InfiniBand cable |
U20 |
9A |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
9B |
1 meter QDR InfiniBand cable |
U20 |
10A |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
10B |
1 meter QDR InfiniBand cable |
U20 |
11A |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
11B |
1 meter QDR InfiniBand cable |
U1 |
1B |
U20 |
Sun Datacenter InfiniBand Switch 36 switch |
8B |
3 meter QDR InfiniBand cable |
U1 |
0B |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
8B |
3 meter QDR InfiniBand cable |
Table 20-19 lists the location, ports and cables for the InfiniBand connections for Oracle Exadata Database Machine X3-2 Quarter Rack and Oracle Exadata Database Machine X3-2 Eighth Rack.
Note:
The same rules and restrictions apply to Oracle Exadata Database Machine X3-2 Eighth Rack as for Oracle Exadata Database Machine X3-2 Quarter Rack.
Table 20-19 InfiniBand Network Cabling for Oracle Exadata Database Machine X3-2 Quarter Rack and Oracle Exadata Database Machine X3-2 Eighth Rack
From InfiniBand Switch Rack Unit | Port | To Rack Unit | Type of Equipment | Port | Cable Description |
---|---|---|---|---|---|
U22 |
13B |
U17 |
Database server |
PCIe 3, P2 |
2 meter QDR InfiniBand cable |
U22 |
14A |
U16 |
Database server |
PCIe 3, P2 |
2 meter QDR InfiniBand cable |
U22 |
16B |
U6 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U22 |
17A |
U4 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U22 |
17B |
U2 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U20 |
13B |
U17 |
Database server |
PCIe 3, P1 |
2 meter QDR InfiniBand cable |
U20 |
14A |
U16 |
Database server |
PCIe 3, P1 |
2 meter QDR InfiniBand cable |
U20 |
16B |
U6 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U20 |
17A |
U4 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U20 |
17B |
U2 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U20 |
9B |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
9A |
1 meter QDR InfiniBand cable |
U20 |
10B |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
10A |
1 meter QDR InfiniBand cable |
U20 |
11B |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
11A |
1 meter QDR InfiniBand cable |
U20 |
8A |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
8A |
1 meter QDR InfiniBand cable |
U20 |
9A |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
9B |
1 meter QDR InfiniBand cable |
U20 |
10A |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
10B |
1 meter QDR InfiniBand cable |
U20 |
11A |
U22 |
Sun Datacenter InfiniBand Switch 36 switch |
11B |
1 meter QDR InfiniBand cable |
Table 20-20 lists the location, ports and cables for the InfiniBand connections for Oracle Exadata Database Machine X3-8 Full Rack with Exadata Storage Server X4-2L Servers.
Table 20-20 InfiniBand Network Cabling for Oracle Exadata Database Machine X3-8 Full Rack with Exadata Storage Server X4-2L Servers
From InfiniBand Switch Rack Unit | Port | To Rack Unit | Type of Equipment | Port | Cable Description |
---|---|---|---|---|---|
U23 |
0A |
U41 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U23 |
0B |
U39 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U23 |
1A |
U37 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U23 |
1B |
U35 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U23 |
2A |
U33 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U23 |
2B |
U31 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U23 |
3A |
U29 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U23 |
3B |
U24 |
Database server |
EM-3.0 P-O |
2 meter QDR InfiniBand cable |
U23 |
4A |
U24 |
Database server |
EM-2.0 P-O |
2 meter QDR InfiniBand cable |
U23 |
4B |
U24 |
Database server |
EM-1.0 P-O |
2 meter QDR InfiniBand cable |
U23 |
5A |
U24 |
Database server |
EM-0.0 P-O |
2 meter QDR InfiniBand cable |
U23 |
13A |
U16 |
Database server |
EM-2.0 P-1 |
2 meter QDR InfiniBand cable |
U23 |
13B |
U16 |
Database server |
EM-1.0 P-1 |
2 meter QDR InfiniBand cable |
U23 |
14A |
U16 |
Database server |
EM-0.0 P-1 |
2 meter QDR InfiniBand cable |
U23 |
12B |
U16 |
Database server |
EM-3.0 P-1 |
2 meter QDR InfiniBand cable |
U23 |
14B |
U14 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U23 |
15A |
U12 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U23 |
15B |
U10 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U23 |
16A |
U8 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U23 |
16B |
U6 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U23 |
17A |
U4 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U23 |
17B |
U2 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U21 |
0A |
U41 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U21 |
0B |
U39 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U21 |
1A |
U37 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U21 |
1B |
U35 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U21 |
2A |
U33 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U21 |
2B |
U31 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U21 |
3A |
U29 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U21 |
3B |
U24 |
Database server |
EM-3.0 P-1 |
2 meter QDR InfiniBand cable |
U21 |
4A |
U24 |
Database server |
EM-2.0 P-1 |
2 meter QDR InfiniBand cable |
U21 |
4B |
U24 |
Database server |
EM-1.0 P-1 |
2 meter QDR InfiniBand cable |
U21 |
5A |
U24 |
Database server |
EM-0.0 P-1 |
2 meter QDR InfiniBand cable |
U21 |
12B |
U16 |
Database Server |
EM-3.0 P-O |
2 meter QDR InfiniBand cable |
U21 |
13A |
U16 |
Database server |
EM-2.0 P-O |
2 meter QDR InfiniBand cable |
U21 |
13B |
U16 |
Database server |
EM-1.0 P-O |
2 meter QDR InfiniBand cable |
U21 |
14A |
U16 |
Database server |
EM-0.0 P-O |
2 meter QDR InfiniBand cable |
U21 |
14B |
U14 |
Exadata Storage Server |
PCIe 3, P1 |
2 meter QDR InfiniBand cable |
U21 |
15A |
U12 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U21 |
15B |
U10 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U21 |
16A |
U8 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U21 |
16B |
U6 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U21 |
17A |
U4 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U21 |
17B |
U2 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U21 |
9B |
U23 |
Sun Datacenter InfiniBand Switch 36 switch |
9A |
1 meter QDR InfiniBand cable |
U21 |
10B |
U23 |
Sun Datacenter InfiniBand Switch 36 switch |
10A |
1 meter QDR InfiniBand cable |
U21 |
11B |
U23 |
Sun Datacenter InfiniBand Switch 36 switch |
11A |
1 meter QDR InfiniBand cable |
U21 |
8A |
U23 |
Sun Datacenter InfiniBand Switch 36 switch |
8A |
1 meter QDR InfiniBand cable |
U21 |
9A |
U23 |
Sun Datacenter InfiniBand Switch 36 switch |
9B |
1 meter QDR InfiniBand cable |
U21 |
10A |
U23 |
Sun Datacenter InfiniBand Switch 36 switch |
10B |
1 meter QDR InfiniBand cable |
U21 |
11A |
U23 |
Sun Datacenter InfiniBand Switch 36 switch |
11B |
1 meter QDR InfiniBand cable |
Table 20-21 lists the location, ports and cables for the InfiniBand connections for Oracle Exadata Database Machine X3-8 Full Rack with Exadata Storage Server X3-2 Servers.
Table 20-21 InfiniBand Network Cabling for Oracle Exadata Database Machine X3-8 Full Rack with Exadata Storage Server X3-2 Servers
From InfiniBand Switch Rack Unit | Port | To Rack Unit | Type of Equipment | Port | Cable Description |
---|---|---|---|---|---|
U23 |
0A |
U41 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U23 |
0B |
U39 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U23 |
1A |
U37 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U23 |
1B |
U35 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U23 |
2A |
U33 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U23 |
2B |
U31 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U23 |
3A |
U29 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U23 |
3B |
U24 |
Database server |
EM-3.0 P-O |
2 meter QDR InfiniBand cable |
U23 |
4A |
U24 |
Database server |
EM-2.0 P-O |
2 meter QDR InfiniBand cable |
U23 |
4B |
U24 |
Database server |
EM-1.0 P-O |
2 meter QDR InfiniBand cable |
U23 |
5A |
U24 |
Database server |
EM-0.0 P-O |
2 meter QDR InfiniBand cable |
U23 |
13A |
U16 |
Database server |
EM-2.0 P-1 |
2 meter QDR InfiniBand cable |
U23 |
13B |
U16 |
Database server |
EM-1.0 P-1 |
2 meter QDR InfiniBand cable |
U23 |
14A |
U16 |
Database server |
EM-0.0 P-1 |
2 meter QDR InfiniBand cable |
U23 |
12B |
U16 |
Database server |
EM-3.0 P-1 |
2 meter QDR InfiniBand cable |
U23 |
14B |
U14 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U23 |
15A |
U12 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U23 |
15B |
U10 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U23 |
16A |
U8 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U23 |
16B |
U6 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U23 |
17A |
U4 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U23 |
17B |
U2 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U21 |
0A |
U41 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U21 |
0B |
U39 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U21 |
1A |
U37 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U21 |
1B |
U35 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U21 |
2A |
U33 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U21 |
2B |
U31 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U21 |
3A |
U29 |
Exadata Storage Server |
PCIe 3, P2 |
3 meter QDR InfiniBand cable |
U21 |
3B |
U24 |
Database server |
EM-3.0 P-1 |
2 meter QDR InfiniBand cable |
U21 |
4A |
U24 |
Database server |
EM-2.0 P-1 |
2 meter QDR InfiniBand cable |
U21 |
4B |
U24 |
Database server |
EM-1.0 P-1 |
2 meter QDR InfiniBand cable |
U21 |
5A |
U24 |
Database server |
EM-0.0 P-1 |
2 meter QDR InfiniBand cable |
U21 |
12B |
U16 |
Database Server |
EM-3.0 P-O |
2 meter QDR InfiniBand cable |
U21 |
13A |
U16 |
Database server |
EM-2.0 P-O |
2 meter QDR InfiniBand cable |
U21 |
13B |
U16 |
Database server |
EM-1.0 P-O |
2 meter QDR InfiniBand cable |
U21 |
14A |
U16 |
Database server |
EM-0.0 P-O |
2 meter QDR InfiniBand cable |
U21 |
14B |
U14 |
Exadata Storage Server |
PCIe 3, P1 |
2 meter QDR InfiniBand cable |
U21 |
15A |
U12 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U21 |
15B |
U10 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U21 |
16A |
U8 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U21 |
16B |
U6 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U21 |
17A |
U4 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U21 |
17B |
U2 |
Exadata Storage Server |
PCIe 3, P1 |
3 meter QDR InfiniBand cable |
U23 |
8B |
U1 |
Sun Datacenter InfiniBand Switch 36 switch |
0B |
3 meter QDR InfiniBand cable |
U21 |
8B |
U1 |
Sun Datacenter InfiniBand Switch 36 switch |
1B |
3 meter QDR InfiniBand cable |
U21 |
9B |
U23 |
Sun Datacenter InfiniBand Switch 36 switch |
9A |
1 meter QDR InfiniBand cable |
U21 |
10B |
U23 |
Sun Datacenter InfiniBand Switch 36 switch |
10A |
1 meter QDR InfiniBand cable |
U21 |
11B |
U23 |
Sun Datacenter InfiniBand Switch 36 switch |
11A |
1 meter QDR InfiniBand cable |
U21 |
8A |
U23 |
Sun Datacenter InfiniBand Switch 36 switch |
8A |
1 meter QDR InfiniBand cable |
U21 |
9A |
U23 |
Sun Datacenter InfiniBand Switch 36 switch |
9B |
1 meter QDR InfiniBand cable |
U21 |
10A |
U23 |
Sun Datacenter InfiniBand Switch 36 switch |
10B |
1 meter QDR InfiniBand cable |
U21 |
11A |
U23 |
Sun Datacenter InfiniBand Switch 36 switch |
11B |
1 meter QDR InfiniBand cable |
U1 |
1B |
U21 |
Sun Datacenter InfiniBand Switch 36 switch |
8B |
3 meter QDR InfiniBand cable |
U1 |
0B |
U23 |
Sun Datacenter InfiniBand Switch 36 switch |
8B |
3 meter QDR InfiniBand cable |