15.3 Administrative Ethernet Port Cabling
This topic describes the administrative network cabling in Oracle Exadata X9M.
The Management Network Switch is located in rack unit 21 on Oracle Exadata X9M-2 racks and in rack unit 22 on Oracle Exadata X9M-8 racks.
In the following tables, Un denotes the unit height in the rack, where n is the number, such as U20. The cables used for the Management Network Switch are blue in color. The following tables are in this section:
- Table 15-3 Administrative Network Cabling for Oracle Exadata X9M-2 Full Rack
- Table 15-4 Administrative Network Cabling for Oracle Exadata X9M-8 Full Rack
Table 15-3 Administrative Network Cabling for Oracle Exadata X9M-2 Full Rack
From Rack Unit | Type of Equipment | Management Network Switch Port |
---|---|---|
U39 |
Storage Server |
1 |
U37 |
Storage Server |
3 |
U35 |
Storage Server |
5 |
U33 |
Storage Server |
7 |
U31 |
Storage Server |
9 |
U29 |
Storage Server |
11 |
U27 |
Storage Server |
13 |
U26 |
Database server |
15 |
U25 |
Database server |
17 |
U24 |
Database server |
19 |
U23 |
Database server |
21 |
U22 |
RDMA Network Fabric Switch |
45 |
U20 |
RDMA Network Fabric Switch |
46 |
U19 |
Database server |
23 |
U18 |
Database server |
25 |
U17 |
Database server |
27 |
U16 |
Database server |
29 |
U14 |
Storage Server |
31 |
U12 |
Storage Server |
33 |
U10 |
Storage Server |
35 |
U8 |
Storage Server |
37 |
U6 |
Storage Server |
39 |
U4 |
Storage Server |
41 |
U2 |
Storage Server |
43 |
U1 |
RDMA Network Fabric Switch Note that the spine switch is not included by default on Oracle Exadata X9M-2 racks, but port 47 is still reserved on the Management Network Switch for the spine RDMA Network Fabric switch. |
47 |
Table 15-4 Administrative Network Cabling for Oracle Exadata X9M-8 Full Rack
From Rack Unit | Type of Equipment | Management Network Switch Port |
---|---|---|
U41 |
Storage Server |
1 |
U39 |
Storage Server |
3 |
U37 |
Storage Server |
5 |
U35 |
Storage Server |
7 |
U33 |
Storage Server |
9 |
U31 |
Storage Server |
11 |
U29 |
Storage Server |
13 |
U24 |
Database server |
15 |
U23 |
RDMA Network Fabric Switch |
33 |
U21 |
RDMA Network Fabric Switch |
34 |
U16 |
Database server |
17 |
U14 |
Storage Server |
19 |
U12 |
Storage Server |
21 |
U10 |
Storage Server |
23 |
U8 |
Storage Server |
25 |
U6 |
Storage Server |
27 |
U4 |
Storage Server |
29 |
U2 |
Storage Server |
31 |
U1 |
RDMA Network Fabric Switch Note that the spine switch is not included by default on Oracle Exadata X9M-8 racks, but port 47 is still reserved on the Management Network Switch for the spine RDMA Network Fabric switch. |
35 |
Parent topic: Cabling Tables for Oracle Exadata X9M