B Replacement Units
This appendix lists the replacement units for the components in Oracle Big Data Appliance racks. All replacement units are field replaceable units (FRUs), which are installed by Oracle field engineers.
This appendix contains the following sections:
See Also:
B.1 About Repair Categories
Repair categories describe the potential effects of a repair action.
Table B-1 Oracle Big Data Appliance Repair Categories
Category | Description | Examples |
---|---|---|
The repair part is hot swappable and can be replaced without shutting down the host system. Procedures may be needed before and after replacement to protect the data. |
|
|
This is the repair of a connectivity component within an Oracle Big Data Appliance rack. No downtime of the rack is required. However, individual components may require downtime. |
|
|
Repair of the part requires shutting down one Big Data Appliance server. No downtime of the rack is required; however, individual servers may require downtime and temporary removal from the cluster. Rebalancing the workload and data duplication may temporarily affect performance. If the system is currently running, then shut it down gracefully. See "Powering On and Off Oracle Big Data Appliance" for additional information. If you monitor the system using Oracle Enterprise Manager Cloud Control, then prevent unnecessary alerts by putting the target in a blackout state. Refer to Oracle Enterprise Manager Administration for additional information. |
|
B.2 Disk Controller Batteries
The disk controllers in the servers have battery-backed write cache to accelerate write performance. If the battery charge capacity degrades such that the battery cannot protect the cached data for a power loss of 48 hours or more, then the write cache is disabled and the disk controller switches to write through mode. This results in reduced write performance but no data loss. The servers generate an alert when the battery charge is insufficient, when the temperature is high, and when the battery should be replaced.
Battery charge capacity degrades over time, and the life expectancy of a battery is inversely proportional to the operating temperature. The worst-case life expectancy of a battery in an Oracle Big Data Appliance rack is as follows:
Inlet Ambient Temperature | Battery Lifetime |
---|---|
< 25 degrees Celsius (77 degrees Fahrenheit) |
3 years |
< 32 degrees Celsius (90 degrees Fahrenheit) |
2 years |
Oracle replaces failed batteries at no extra charge if the battery charge capacity in the disk controllers falls below the minimum threshold. As part of Oracle Premier Support for Systems, Oracle attempts to proactively replace the batteries in an Oracle Big Data Appliance rack before the end of the estimated lifetime, on a best effort basis.
B.3 LED Status Descriptions
This section describes the light-emitting diodes (LEDs) in an Oracle Big Data Appliance rack. It contains these topics:
B.3.1 Sun Server LEDs
Table B-2 identifies some LED status indicators on the Sun Server X4-2L and X3-2L that can indicate a fault.
See Also:
"About Server and Component Status Indicators" in the Sun Server X4-2 Service Manual at
http://docs.oracle.com/cd/E36975_01/html/E38045/z4000be71405942.html#scrolltoc
Table B-2 Sun Server LED Status Descriptions
B.3.2 Sun InfiniBand Switch LEDs
Table B-3 identifies some LED status indicators on Sun Datacenter InfiniBand Switch 36 and Sun Network QDR InfiniBand Gateway switches that can indicate a fault.
See Also:
-
"Identifying LEDs" in the Sun Datacenter InfiniBand Switch 36 Service Manual at
http://docs.oracle.com/cd/E26698_01/html/E26434/z40000fe1394411.html
-
"Identifying LEDs" in the Sun Network QDR InfiniBand Gateway Switch Service Manual at
http://docs.oracle.com/cd/E26699_01/html/E26706/z40000fe1394411.html
Table B-3 Sun InfiniBand Switch LED Status Descriptions
B.4 Parts for Oracle Big Data Appliance Servers
The following topics identify the replacement parts for the Oracle Big Data Appliance storage servers:
B.4.1 Oracle Server X7-2L Parts
The following are replaceable parts for the X7-2L server.
Note:
This parts list is specific to X7-2L for Oracle Big Data Appliance. There are some differences in the X7-2L parts list for Oracle Big Data Appliance, Exadata Database Machine, and other products.See Also:
If a repair procedure includes powering down the server, see the instructions in the Oracle Server X7-2 Service Manual , which provides the steps for graceful shutdown (or immediate shutdown, if needed).
The Oracle Servers X7-2 and X7-2L Installation Guide shows the server’s front and back panels. Note that the “Do Not Service” indicator on the front panel is not used in Oracle Big Data Appliance.
Table B-4 Replacement Parts for Oracle Server X7-2L Oracle Database Servers
Part Number | Description | Repair Category | Coverage under Basic Warranty | Repair Procedure |
---|---|---|---|---|
7346413 |
SWITCH,CISCO NEXUS 93108TC-EX (1GB),PORT-SIDE EXHAUST |
DBO |
FRU |
Oracle Servers X7-2 and X7-2L Installation Guide |
7046514 |
Assy, single slide rail,snap in, 919mm, EXA products |
DBO |
FRU |
|
370-5621 |
3 volt lithium battery |
DBO |
FRU |
See "Servicing the Battery (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqviw.html#scrolltoc |
7332759 |
Assy,Drive,10TB,3.5",SAS3/7200rpm,Coral |
HS |
CRU |
See "Servicing Storage Drives" in Oracle Server X7-2 Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtcs.html#scrolltoc |
7341587 |
M.2,150GB,SATA,22x80mm,SSD,INTEL, DC S3520 |
DBO |
FRU |
See "Servicing Storage Drives (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gquak.html#scrolltoc |
7332759 |
Assy,Drive,10TB,3.5",SAS3/7200rpm,Coral |
HS |
CRU |
See "Servicing Storage Drives" in Oracle Server X7-2 Manual at http://docs.oracle.com/cd/E72463_01/html/E72474/gqtcs.html#scrolltoc |
7341466 |
ASM,MECH,M.2,X7-2L. |
DBO |
FRU |
No repair procedure available. |
7322171 |
ASM, LFIM, X7-2L |
DBO |
FRU |
See "Servicing Other Cables" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvev.html#scrolltoc |
7046442 |
Assembly, dual port, QDR CX3, host channel adapter |
DBO |
FRU |
|
7332895 |
HBA,12GB SAS3 PCIe 16 PORT RAID-INT (w/FLASH MOD),VAIL |
DBO |
FRU |
|
7322160 |
HEATSINK,CPU,X7-2L |
DBO |
FRU |
See "Servicing Processors (FRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqtmk.html#scrolltoc |
7330698 |
DIMM, 32 GB, RDIMM, DDR4, 2666 |
DBO |
FRU |
See "Servicing the DIMMs (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvkr.html#scrolltoc |
7333459 |
Power supply, AC, A266, F, 12V, 1200W |
HS |
FRU |
The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.
|
7332895 |
HBA, 12 Gb SAS PCIe 16-port RAID internal with flash module |
DBO |
FRU |
See "Servicing the Internal HBA Card and HBA Super Capacitor (FRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvmq.html#scrolltoc |
7086345 |
Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA |
DBO |
FRU |
See "Servicing the Internal HBA Card (FRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E62159_01/html/E62171/goeht.html#scrolltoc |
7315464 |
CBL,SAS3,X7-2L |
DBO |
FRU |
See "Servicing the Internal HBA SAS Cable assembly" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvav.html#scrolltoc |
7331123 7322166 |
Fan module |
HS |
FRU |
See "Servicing Fan Modules (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gquhg.html#scrolltoc |
7346820 |
CPU, XEON P-8160, 2.1 GHz, 150W, 24 core, (SR3B0) |
DBO |
FRU |
See "Servicing Processors (FRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqtmk.html#scrolltoc |
7341141 |
ASM,12-DBP_UNI,2U |
DBO |
FRU |
See "Servicing the Disk Backplane (FRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvap.html#scrolltoc |
7335280 |
ASM, MB MECH, X7-2L |
DBO |
FRU |
|
7346413 |
SWITCH,CISCO NEXUS 93108TC-EX (1GB),PORT-SIDE EXHAUST |
DBO |
FRU |
No repair procedure available. |
7346902 |
COOLING FAN,CISCO NEXUS 9K,PORT-SIDE EXHAUST FLOW |
DBO |
FRU |
No repair procedure available. |
7346904 |
PSU,CISCO NEXUS 9000 650W AC,PORT-SIDE EXHAUST |
DBO |
FRU |
No repair procedure available. |
B.4.2 Oracle Server X6-2L and X5-2L Parts
Figure B-1 shows the front view of the Oracle Server X6-2L and X5-2L. The hard drives are numbered from left to right, starting in the lower left. The drives in the bottom row are numbers 0, 1, 2, and 3. The drives in the middle row are numbers 4, 5, 6, and 7. The drives in the top row are numbers 8, 9, 10, and 11.
Figure B-1 Front View of Oracle Servers X6-2L and X5-2L

Description of "Figure B-1 Front View of Oracle Servers X6-2L and X5-2L"
Figure B-2 shows the rear view of a Oracle Server X6-2L or X5-2L storage server.
Figure B-2 Rear View of Oracle Servers X6-2L and X5-2L

Description of "Figure B-2 Rear View of Oracle Servers X6-2L and X5-2L"
Table B-5 lists the replaceable parts for the Oracle Server X6-2L and X5-2L, which are covered under the Oracle Premier Support for Systems warranty. The parts list for X6-2L and X5-2L are nearly the same except for CPUs and DIMMs. Unless otherwise noted, the repair procedures are in the Oracle Server X5-2L Service Manual.
Note:
All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.
Table B-5 Replacement Parts for Oracle Server X6-2L and X5-2L Servers
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
350-1719 |
Assembly, 1U-2U Snap-in, slim rail rack |
EBO |
|
370-5621 |
3V lithium battery |
EBO |
See "Servicing the Battery" at
|
7014226 |
Cable, interlock, 125 mm |
EBO |
See "Servicing SAS Cables" at
|
7017231 |
Indicator assembly, right |
EBO |
See "Servicing the Front LED/USB Indicator Modules" at
|
7023515 |
Disk backplane assembly, 2 rear |
EBO |
See "Servicing the Front and Rear Storage Drive Backplanes" at
|
7044130 |
Power Supply, A258, 1000W, AC Input |
HS |
|
7045042 |
Fan assembly, 2U, 80 x 80, Ferrite, center rotate |
HS |
See "Servicing Fan Modules" at
|
7046442 |
Assembly, dual port, QDR CX3, host channel adapter |
EBO |
|
7064884 |
Heat sink, CPU (Oracle Server X5-2L) |
EBO |
See "Servicing Storage Drives (CRU)" in Sun Server X5-2 Service Manual at
|
7067728 |
Pre-Greased 1U CPU Heatsink (Oracle Server X6-2L) |
See "Servicing Storage Drives (CRU)" in Sun Server X5-2 Service Manual at |
|
7066824 |
Assembly, drive, 8 TB, 3.5 inch, SAS/7200rpm |
HS |
See "Servicing Storage Drives and Rear Drives" in Sun Server X5-2 Service Manual at
|
7069337 |
Assembly, backplane, 12X3.5, W/SAS expansion, 2U |
EBO |
See "Servicing the Front and Rear Storage Drive Backplanes" at
|
7078071 |
DIMM 16 GB (Oracle Server X5-2L) |
EBO |
See "Servicing the DIMMs" at
|
7310210 |
32GB DDR4-2400 DIMM (Oracle Server X6-2L) |
See “Servicing the DIMMs” at
|
|
7085209 |
HBA, 12 Gb SAS PCIe 8-port RAID internal with flash module |
EBO |
See "Servicing the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card" at
|
7086345 |
Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA |
EBO |
See "Servicing the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card" at
|
7086346 |
Cable, super cap, 620M, 6-pin, straight, SAS3 HBA |
EBO |
See "Servicing SAS Cables" at
|
7090170 |
Flash drive, MLC, OSA ID, USB, 8 GB |
EBO |
See "Servicing the Internal USB Flash Drives" at
|
7095106 |
CPU, 2.3GHz 18-Core E5-2699 (Oracle Server X5-2L) |
EBO |
Caution: Processors should be removed and replaced only by authorized Oracle Service personnel.
|
7313670 |
CPU, 22-Core 2.2GHz Intel E5-2699 v4, 145W (Oracle Server X6–2L) |
Caution: Processors should be removed and replaced only by authorized Oracle Service personnel.
|
|
7096185 |
Assembly, indicator, left |
EBO |
See "Servicing the Front LED/USB Indicator Modules" at
|
7098504 |
ASM, MOBO tray |
EBO |
B.4.3 Sun Server X4-2L Parts
Table B-7 lists the replaceable parts for the Sun Server X4-2L, which are covered under the Oracle Premier Support for Systems warranty. Unless otherwise noted, the repair procedures are in the Sun Server X4-2 Service Manual.
Table B-6 Replacement Parts for a Sun Server X4-2L Server
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
150-3993 |
Battery, 3V, 390 MAH, LITH, COIN |
BDA-O |
See "Servicing the Battery" at
|
7090170 |
8 GB USB flash drive |
BDA-O |
See "Servicing the Internal USB Flash Drives" at
|
371-4985 |
6 Gigabit SAS RAID PCI battery module, RoHS:Y (LION), BBU-08 |
BDA-O |
|
7047503 |
Niwot card |
BDA-O |
|
7057184 |
Assembly Battery Carrier Remote |
HS |
Oracle internal service documentation |
7082397 |
InfiniBand dual port, QDR CX3, HCA |
BDA-O |
|
375-3701 |
6 Gbps SAS RAID disk PCIe HBA, RoHS:Y |
BDA-O |
Note: Do not run any controller commands when replacing the disk. |
7066826 |
Drive, 8 TB, 3.5", SAS/7200 RPM, CORAL |
HS |
See "Servicing Storage Drives" at
Do not run any controller commands when replacing the disk. |
7014391 |
SAS expander assembly |
BDA-O |
See "Servicing the SAS Expander Module" at
|
7020486 |
DIMM, 8 GB, DDR3, 1600 MHz, 1.3V |
BDA-O |
See "Servicing the DIMMs" at
|
7018701 |
DIMM, 16 GB, DDR3, 1600 MHz, 1.35V |
BDA-O |
See "Servicing the DIMMs" at
|
7071891 |
LRDIMM,32GB,DDR3,1600,4Rx4,1.35V |
BDA-O |
See "Servicing the DIMMs" at
|
7020774 |
Pregreased CPU heatsink |
BDA-O |
See "Servicing Processors" at
|
7075289 |
CPU, Intel E5-2650 v2 8-core 2.6 GHz |
BDA-O |
See "Servicing Processors" at
|
7044130 |
Power supply, AC, A258, F, 12V, 1000W |
HS |
See "Servicing Power Supplies" at
|
7045042 |
Dual counter rotating fan module, 80x80 mm |
HS |
See "Servicing Fan Modules" at
|
7047257 |
12-slot backplane cable kit with the following:
|
BDA-O |
|
7047768 |
12-slot 3.5" disk cage, including fan door, and left and right ear assembly |
BDA-O |
|
7049382 |
System board assembly, RoHS:Y |
BDA-O |
|
B.4.4 Sun Server X3-2L Parts
Table B-7 lists the replaceable parts for the Sun Server X3-2L, which are covered under the Oracle Premier Support for Systems warranty. Unless otherwise noted, the repair procedures are in the Sun Server X3-2L Service Manual.
Table B-7 Replacement Parts for a Sun Server X3-2L Server
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
150-3993 |
Battery, 3V, 390 MAH, LITH, COIN |
BDA-O |
See "Servicing the Battery" at
Note: Rear storage drive 1 might be populated with a remote battery module for the host bus adapter (HBA) card. See "Remove a Rear Storage Drive" at
|
7090170 |
8 GB USB flash drive |
BDA-O |
See "Servicing the Internal USB Flash Drives" at
|
371-4985 |
6 Gigabit SAS RAID PCI battery module, RoHS:Y (LION), BBU-08 |
BDA-O |
|
7047503 |
Niwot card |
BDA-O |
|
7057184 |
Assembly Battery Carrier Remote |
HS |
See "Remove a Rear Storage Drive" at
|
375-3696 |
InfiniBand (CX2) dual port CX2 4x QDR PCI-e |
BDA-O |
|
375-3701 |
6 Gbps SAS RAID disk PCIe HBA, RoHS:Y |
BDA-O |
Note: Do not run any controller commands when replacing the disk. |
7010036 |
DR 3 TB, 3.5-inch, SAS/7200, CORAL |
HS |
See "Servicing Storage Drives and Rear Drives" at
Do not run any controller commands when replacing the disk. Note: Rear storage drive 1 might be populated with a remote battery module for the host bus adapter (HBA) card. See "Remove a Rear Storage Drive" at
|
7014391 |
SAS expander assembly |
BDA-O |
See "Servicing the SAS Expander Module" at
|
7020486 |
DIMM, 8 GB, DDR3, 1600 MHz, 1.3V |
BDA-O |
See "Servicing the DIMMs" at
|
7018704 |
DIMM, 16 GB, DDR3, 1600 MHz, 1.35V |
BDA-O |
See "Servicing the DIMMs" at
|
7071891 |
LRDIMM,32GB,DDR3,1600,4Rx4,1.35V |
BDA-O |
See "Servicing the DIMMs" at
|
7020774 |
Pregreased CPU heatsink |
BDA-O |
See "Servicing Processors" at
|
7026881 |
CPU,Intel,E5-2660,2.2 GHz, 8-core |
BDA-O |
See "Servicing Processors" at
|
7044130 |
Power supply, AC, A258, F, 12V, 1000W |
HS |
See "Servicing Power Supplies" at
|
7045042 |
Dual counter rotating fan module, 80x80 mm |
HS |
See "Servicing Fan Modules" at
|
7047257 |
12-slot backplane cable kit with the following:
|
BDA-O |
|
7047768 |
12-slot 3.5" disk cage, including fan door, and left and right ear assembly |
BDA-O |
|
7049382 |
System board assembly, RoHS:Y |
BDA-O |
|
B.4.5 Sun Fire X4270 M2 Parts
Table B-8 lists the replaceable parts for the Sun Fire X4270 M2, which are covered under the Oracle Premier Support for Systems warranty. Unless otherwise noted, the repair procedures are in the Sun Fire X4270 M2 Server Service Manual.
Table B-8 Replacement Parts for Sun Fire X4270 M2 Servers
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
150-3993 |
Battery, 3V, 390 MAH, LITH, COIN |
BDA-O |
See Section 4.6, "Servicing the Server Battery" in Sun Fire X4270 M2 Server Service Manual at
|
300-2235 |
Power supply, A249, 1200W, 12V, 2U, RoHS:Y |
HS |
See Section 3.4, "Servicing Power Supplies" in Sun Fire X4270 M2 Server Service Manual at
|
350-1502 |
Universal rack mount kit |
BDA-O |
|
7090170 |
8 GB USB flash drive |
BDA-O |
Not applicable |
371-4966 |
LV DIMM, 8 GB, DDR3, 1RX4, 1333 MHz |
BDA-O |
See Section 4.2, "Servicing Memory Modules (DIMMs)" in Sun Fire X4270 M2 Server Service Manual at
|
371-4982 |
6 Gigabit SAS RAID PCI battery module, RoHS:Y (LION), BBU-08 |
BDA-O |
|
375-3696 |
InfiniBand (CX2) dual port CX2 4x QDR PCI-e |
BDA-O |
|
375-3701 |
6 Gbps SAS RAID disk PCIe HBA, RoHS:Y |
BDA-O |
Note: Do not run any controller commands in the service manual when replacing the disk. |
530-3927 |
Cable, PDB, MB, 1U+2U, ribbon |
BDA-O |
See Section 5.10, "Servicing Cables " in Sun Fire X4270 M2 Server Service Manual at
|
530-4228 |
Cable, mini-SAS, 36 POS LONG, LY, RoHS:Y |
BDA-O |
See Section 5.10, "Servicing Cables" in Sun Fire X4270 M2 Server Service Manual at
|
541-2075 |
Bus_bar, power, 1U+2U, RoHS:Y |
BDA-O |
See Section 5.6, "Servicing the Power Distribution Board" in Sun Fire X4270 M2 Server Service Manual at
|
541-2884 |
Assembly, riser, X8, X8, 2U, PCI-E, RoHS:Y |
BDA-O |
See Section 4.4, "Servicing PCIe Risers" in Sun Fire X4270 M2 Server Service Manual at
|
541-3310 |
Xeon Heatsink with grease, RoHS:Y, 2U |
BDA-O |
See Section 4.7, "Servicing CPUs" in Sun Fire X4270 M2 Server Service Manual at
|
541-3356 |
x8/x8 switched PCIe riser assembly, RoHS:Y with the following:
|
BDA-O |
|
541-4081 |
System board assembly, RoHS:Y |
BDA-O |
|
541-4124 |
Fan deck, Hyde, RoHS:Y |
BDA-O |
See Section 5.3, "Servicing the Fan Board" in Sun Fire X4270 M2 Server Service Manual at
|
541-4222 |
Assembly, fan, CR, 2U, RoHS:Y |
HS |
See Section 3.3, "Servicing Fan Modules" in Sun Fire X4270 M2 Server Service Manual at
|
541-4223 |
Power distribution board, 2U, RoHS:Y |
BDA-O |
See Section 5.6, "Servicing the Power Distribution Board" in Sun Fire X4270 M2 Server Service Manual at
|
541-4304 |
Indicator, right, Hyde 12/24, RoHS:Y |
BDA-O |
See Section 5.5, "Servicing the Front Panel LED Modules" in Sun Fire X4270 M2 Server Service Manual at
|
541-4305 |
Assembly, disk, SAS2, XP_DC, Hyde, RoHS:Y |
BDA-O |
See Section 5.2, "Servicing the SAS Expander Board" in Sun Fire X4270 M2 Server Service Manual at
|
541-4306 |
Assembly, connector board bracket, Hyde |
BDA-O |
See Section 5.7, "Servicing the Connector Board" in Sun Fire X4270 M2 Server Service Manual at
|
541-4363 |
12-slot disk backplane, RoHS:Y |
BDA-O |
See Section 5.4, "Servicing the Disk Backplane" in Sun Fire X4270 M2 Server Service Manual at
|
541-4371 |
Indicator, left, Hyde 12/24, RoHS:Y |
BDA-O |
See Section 5.5, "Servicing the Front Panel LED Modules" in Sun Fire X4270 M2 Server Service Manual at
|
560-2952 |
Cable kit, Hyde, RoHS:Y with the following:
|
BDA-O |
Refer to the entries for the individual items in the kit. |
7010036 |
FRU DR 3 TB 3.5-inch SAS/7200, CORAL |
-- |
See Section 3.2, "Servicing Storage Drives and Boot Drives" in Sun Fire X4270 M2 Server Service Manual at
Note: Do not run any controller commands in the service manual when replacing the disk. |
7012433 |
3.06 GHz processor |
BDA-O |
See Section 4.7, "Servicing CPUs" in Sun Fire X4270 M2 Server Service Manual at
|
B.5 Parts for Sun Datacenter InfiniBand Switch 36
Table B-9 lists the replaceable parts for the Sun Datacenter InfiniBand Switch 36, which are covered under the Oracle Premier Support for Systems warranty. Unless otherwise noted, the repair procedures reference the Sun Datacenter InfiniBand Switch 36 Service Manual at
http://docs.oracle.com/cd/E26698_01/index.html
See "Cables and Cable Accessories for an Oracle Big Data Appliance Rack" for information about InfiniBand cables.
Table B-9 Replacement Parts for the Sun Datacenter InfiniBand Switch 36
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
7081595 |
A247A, 12V, 760-watt power supply, RoHS:Y |
HS |
See "Servicing Power Supplies" at
|
350-1312 |
Fan module for Sun Datacenter InfiniBand Switch 36, RoHS:Y |
HS |
See "Servicing Fans" at
|
371-2210 |
CR2032 3V battery, RoHS:Y |
IR |
See "Servicing the Battery" at
|
541-3495 |
Sun Datacenter InfiniBand Switch 36, RoHS:YL |
IR |
|
594-6603 |
10 Gbps QSFP short wavelength transceiver |
IR |
See "Servicing Data Cables" at
|
B.6 Parts for Sun Network QDR InfiniBand Gateway Switch
Table B-10 lists the replaceable parts for the Sun Network QDR InfiniBand Gateway switch, which are covered under the Oracle Premier Support for Systems warranty. Unless otherwise noted, the repair procedures refer to the Sun Network QDR InfiniBand Gateway Switch Service Manual at
http://docs.oracle.com/cd/E26699_01/index.html
See "Cables and Cable Accessories for an Oracle Big Data Appliance Rack" for information about InfiniBand cables.
Table B-10 Replacement Parts for the Sun Network QDR InfiniBand Gateway Switch
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
7081595 |
A247A, 12V, 760-watt power supply, RoHS:Y |
HS |
See "Servicing Power Supplies" at
|
350-1312 |
Fan module, RoHS:Y |
HS |
See "Servicing Fans" at
|
371-2210 |
CR2032 3V battery, RoHS:Y |
IR |
See "Servicing the Battery" at
|
594-6603 |
10 Gbps QSFP short wavelength transceiver |
IR |
See "Servicing Data Cables" at
|
7014378 |
Assembly, system, NM2-Gateway |
IR |
|
B.7 Parts for the Cisco Ethernet Switch
Table B-11 lists replaceable parts for the Cisco Ethernet switch, which are covered under the Oracle Premier Support for Systems warranty.
See Also:
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html
Table B-11 Replacement Parts for Cisco Catalyst Ethernet
Part Number | Description | Repair Category | Repair |
---|---|---|---|
7055121 |
Cooling fan tray |
HS |
See Chapter 4 of the Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide. |
7055122 |
Power supply, redundant |
HS |
See Chapter 4 of the Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide. |
7055123 |
SNET, WS-C4948E-F |
IR |
See Chapter 3 of the Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide. |
B.8 Parts for Power Distribution Units
Table B-12 lists the replacement parts for the power distribution units (PDUs), which are covered under the Oracle Premier Support for Systems warranty. The repair procedures references the Sun Rack II Power Distribution Units User's Guide at
https://docs.oracle.com/cd/E19657-01/html/E23956/index.html
Because of the number of cables and connections, Oracle recommends shutting down the Oracle Big Data Appliance rack during the replacement of power distribution unit parts.
Table B-12 Replacement Parts for Power Distribution Units
Part Number | Description | Repair Category | Repair Procedures |
---|---|---|---|
180-2379 |
13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 1 meter, RoHS:Y |
HS |
Not applicable |
180-2380 |
13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 2 meter, RoHS:Y |
HS |
Not applicable |
371-3995 |
Three-phase PDU: 15 kVA, IEC309 60A, 4-pin, 250 VAC, three-phase IP67, North America, RoHS:Y |
IR |
See "Removing and Replacing PDUs" at
|
371-4976 |
Three-phase PDU: 15 kVA, 5-pin, IEC309 32A, 5-pin 230/400V, three-phase IP44, international, RoHS:Y |
IR |
See "Removing and Replacing PDUs" at
|
371-4199 |
Single-phase PDU: 15 kVA, with three 30A/250V 2-pole/3-wire NEMA L6-30P plugs, North America, RoHS:Y |
IR |
See "Removing and Replacing PDUs" at
|
371-5040 |
Single-phase PDU: 22 kVA, with three blue 32A/240V splash-proof 2-pole/3-wire IEC 60309 plugs, international, RoHS:Y |
IR |
See "Removing and Replacing PDUs" at
|
B.9 Cables and Cable Accessories for an Oracle Big Data Appliance Rack
Table B-13 lists the replacement cables and cable accessories for an Oracle Big Data Appliance rack, which are covered under the Oracle Premier Support for Systems warranty.
See Also:
-
Sun Network QDR InfiniBand Gateway Switch Service Manual at
http://docs.oracle.com/cd/E26699_01/html/E26706/gentextid-26783.html#scrolltoc
-
Sun Datacenter InfiniBand Switch 36 Service Manual at
http://docs.oracle.com/cd/E26698_01/html/E26434/gentextid-21904.html#scrolltoc
-
See Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at
http://www.cisco.com/en/US/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html
Table B-13 Replacement Cables for an Oracle Big Data Appliance Rack
Part Number | Description | Repair Category | Repair |
---|---|---|---|
350-1287 |
Slim rail, CMA, 1U-2U for Sun servers |
BDA-O |
|
350-1519 |
Serial cable kit, RoHS:Y with the following:
|
HS |
See "Understanding Cabling" in the Sun Datacenter InfiniBand Switch 36 Installation Guide at
|
530-4567 |
4x QSFP copper QDR InfiniBand cable, 2 m, RoHS:Y |
HS |
Note: Redundancy is lost during cable replacement. |
530-4445 |
4x QSFP copper QDR InfiniBand cable, 3 m, RoHS:Y |
HS |
|
530-4446 |
4x QSFP copper QDR InfiniBand cable, 5 m, RoHS:Y |
HS |
|
530-4432 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, blue, RoHS:Y |
HS |
See Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide. |
530-4433 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, red, RoHS:Y |
HS |
See Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide. |
530-4434 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, red, RoHS:Y |
HS |
See Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide. |
530-4435 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, black, RoHS:Y |
HS |
See Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide. |
530-4436 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, black, RoHS:Y |
HS |
See Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide. |