Sun Ethernet Fabric Operating System Uplink Port Trailing Administration Guide

Exit Print View

Updated: February 2015
 
 

Configure NEM24p-0

  1. Start the configuration with all ports and the default VLAN shut down.

    Also, enable the Uplink port trailing feature.


    Tip  - It is a best practice to start the configuration with all the ports and default VLAN shut down. Disable GVRP and GMRP, because dynamic VLAN learning is not suggested.
    NEM24p-0 SEFOS# configure terminal
    NEM24p-0 SEFOS(config)# set gvrp disable
    NEM24p-0 SEFOS(config)# set gmrp disable
    NEM24p-0 SEFOS(config)# set port-channel enable
    NEM24p-0 SEFOS(config)# set uplink-trailing enable
    % Enabling Uplink Trailing Module 
    NEM24p-0 SEFOS(config)# interface vlan 1
    NEM24p-0 SEFOS(config-if)# shutdown
    NEM24p-0 SEFOS(config-if)# no ip address
    NEM24p-0 SEFOS(config-if)# exit
    NEM24p-0 SEFOS(config)# interface range extreme-ethernet 0/1-24
    NEM24p-0 SEFOS(config-if-range)# shutdown
    NEM24p-0 SEFOS(config-if-range)# end
    
  2. Create and enable port-channel between switches according to the topology.
    NEM24p-0 SEFOS# configure terminal
    NEM24p-0 SEFOS(config)# interface port-channel 12
    NEM24p-0 SEFOS(config-if)# no shutdown
    NEM24p-0 SEFOS(config-if)# exit
    NEM24p-0 SEFOS(config)# end
    
  3. Configure VLANs manually.

    You must add at least one port to the VLAN before you can assign the VLAN a name.

    NEM24p-0 SEFOS# configure terminal
    NEM24p-0 SEFOS(config)# vlan 300
    NEM24p-0 SEFOS(config-vlan)# ports add port-channel 12 name vlan-1
    NEM24p-0 SEFOS(config-vlan)# vlan active
    NEM24p-0 SEFOS(config-vlan)# exit
    NEM24p-0 SEFOS(config)# vlan 301
    NEM24p-0 SEFOS(config-vlan)# ports add port-channel 12 name vlan-2
    NEM24p-0 SEFOS(config-vlan)# vlan active
    NEM24p-0 SEFOS(config-vlan)# exit
    NEM24p-0 SEFOS(config)# end
    
  4. Create an uplink trailing group.

    The group number can be 1 to 65355.

    NEM24p-0 SEFOS# configure terminal
    NEM24p-0 SEFOS(config)# uplink-trailing 10
    %  Uplink Trailing Group 10 Created
    NEM24p-0 SEFOS(config-ultr)# description "Uplink-trailing between NEM24p-0 & ToR72p -1"
    NEM24p-0 SEFOS(config-ultr)# end
    
  5. Configure the port-channel to allow all VLANs.
    NEM24p-0 SEFOS# configure terminal
    NEM24p-0 SEFOS(config)# interface port-channel 12
    NEM24p-0 SEFOS(config-if)# switchport mode trunk
    NEM24p-0 SEFOS(config-if)# exit
    NEM24p-0 SEFOS(config)# end
    
  6. Enable the ports and add them to the appropriate port-channels.

    Assign the ports to the uplink-trailing group as uplink or downlink to bind them together

    NEM24p-0 SEFOS# configure terminal
    NEM24p-0 SEFOS(config)# interface range extreme-ethernet 0/1
    NEM24p-0 SEFOS(config-if-range)# description "connected to ToR72p-1"
    NEM24p-0 SEFOS(config-if-range)# channel-group 12 mode active
    NEM24p-0 SEFOS(config-if-range)# uplink-trailing group 10 uplink
    NEM24p-0 SEFOS(config-if-range)# no shutdown
    NEM24p-0 SEFOS(config-if-range)# exit
    NEM24p-0 SEFOS(config)# interface extreme-ethernet 0/18
    NEM24p-0 SEFOS(config-if)# description "connected to Linux blade, Host-2"
    NEM24p-0 SEFOS(config-if)# switchport mode trunk
    NEM24p-0 SEFOS(config-if)# uplink-trailing group 10 downlink
    NEM24p-0 SEFOS(config-if)# no shutdown
    NEM24p-0 SEFOS(config-if)# exit
    NEM24p-0 SEFOS(config)# end
    
  7. Save the configuration.
    NEM24p-0 SEFOS# copy run start
    Building configuration ...
    [OK]