JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Oracle Integrated Lights Out Manager (ILOM) 3.x

Supplement for the Sun Blade 6000 Modular System

search filter icon
search icon

Document Information

Using This Documentation

Downloading Chassis Firmware

Documentation and Feedback

About This Documentation

About Oracle ILOM on the Modular System

Oracle ILOM Overview

Oracle ILOM Features Specific to the Modular System

Modular System Power Usage

Fan Speed Control

Modular System Oracle ILOM CLI Targets

Sun Blade Zone Manager

Oracle ILOM Documentation

Monitoring System Health

Chassis Sensors Overview

Monitoring System Health With ILOM 3.1

Oracle ILOM 3.0 Sensor Information

Sensor Types

Display Sensor Readings in Oracle ILOM 3.0

Chassis Sensors in Oracle ILOM 3.0

Fan Sensors in Oracle ILOM 3.0

Power Supply Sensors in Oracle ILOM 3.0

NEM Sensors in Oracle ILOM 3.0

Server Module Sensors in Oracle ILOM 3.0

SNMP and PET Reference Information

SNMP Traps

PET Event Messages

Index

PET Event Messages

PET events are generated by systems with ASF or an IPMI baseboard management controller. The PET events provide advance warning of possible system failures. For more information about the PET event messages that might occur on your system, see the following table.


Note - For ILOM 3.1, replace /CH with /SYSTEM.


PET Event
PET Sent
Sensor Name
Severity
Description
Temperature Upper critical threshold has been exceeded
petTrapTemperatureUpperNonCriticalGoingHigh
/CH/T_AMB

/CH/PSx/T_AMB

Major
Temperature has increased above upper critical threshold.
Temperature Upper critical threshold no longer exceeded
petTrapTemperatureUpperNonCriticalGoingLowDeassert
/CH/T_AMB

/CH/PSx/T_AMB

Warning
Temperature has decreased below upper critical threshold.
Temperature Lower fatal threshold has been exceeded
petTrapTemperatureUpperNonRecoverableGoingHigh
/CH/T_AMB

/CH/PSx/T_AMB

Critical
Temperature has increased above upper non-recoverable threshold.
Temperature Lower fatal threshold no longer exceeded
petTrapTemperatureUpperNonRecoverableGoingLowDeassert
/CH/T_AMB

/CH/PSx/T_AMB

Major
Temperature has decreased below upper non-recoverable threshold.
Temperature sensor ASSERT
petTrapTemperatureStateAssertedAssert
/CH/HOT
Critical
Temperature event occured. Possible cause: CPU is too hot.
Temperature sensor DEASSERT
petTrapTemperatureStateDeassertedAssert
/CH/HOT
Informational
Temperature event occured.
Entity Presence Insert
petTrapEntityPresenceDeviceInsertedAssert
/CH/BLx/PRSNT

/CH/BLx/HDDx/PRSNT

/CH/BLx/FMODx/PRSNT

/CH/BLx/ESM/PRSNT

/CH/NEMx/PRSNT

/CH/PSx/PRSNT

Informational
A device is present or has been inserted.
Entity Presence Remove
petTrapEntityPresenceDeviceRemovedAssert
/CH/BLx/PRSNT

/CH/BLx/HDDx/PRSNT

/CH/BLx/FMODx/PRSNT

/CH/BLx/ESM/PRSNT

/CH/NEMx/PRSNT

/CH/PSx/PRSNT

Informational
A device is absent or has been removed.
Module Transition to Running assert
petTrapModuleBoardTransitionToRunningAssert
/CH/BLx/STATE

/CH/NEMx/STATE

Informational
A device has transitioned to the normal running state. For a blade, this indicates that the host has powered on.
Module Transition to In Test assert
petTrapModuleBoardTransitionToInTestAssert
/CH/BLx/STATE

/CH/NEMx/STATE

Informational
A device is in a transitional state. (Used only for NEMs.)
Module Transition to Power Off assert
petTrapModuleBoardTransitionToPowerOffAssert
/CH/BLx/STATE

/CH/NEMx/STATE

Informational
A device has powered off.
Module Transition to On Line assert
petTrapModuleBoardTransitionToOnLineAssert
/CH/BLx/STATE

/CH/NEMx/STATE

Informational
A device is online and ready to enter the running state. (Used only for NEMs.)
Module Transition to Off Line assert
petTrapModuleBoardTransitionToOffLineAssert
/CH/BLx/STATE

/CH/NEMx/STATE

Informational
Unused.
Module Transition to Off Duty assert
petTrapModuleBoardTransitionToOffDutyAssert
/CH/BLx/STATE

/CH/NEMx/STATE

Informational
A device is no longer in use and is ready to be removed.
Module Transition to Degraded assert
petTrapModuleBoardTransitionToDegradedAssert
/CH/BLx/STATE

/CH/NEMx/STATE

Informational
A device has entered a state of degraded operation, for example, due to a hardware fault, or an over-temperature condition that caused the device to shut itself down.
Module Transition to Power Save assert
petTrapModuleBoardTransitionToPowerSaveAssert
/CH/BLx/STATE

/CH/NEMx/STATE

Informational
Unused.
Module Install Error assert
petTrapModuleBoardInstallErrorAssert
/CH/BLx/STATE

/CH/NEMx/STATE

Informational
Unused.
OEM Reserved reporting Predictive Failure
petTrapOEMPredictiveFailureAsserted 12583937
/CH/BLx/ERR

/CH/BLx/ESM/ERR

/CH/NEMx/ERR

Major
OEM predictive failure asserted.
OEM Reserved Return to normal
petTrapOEMPredictiveFailureDeasserted
/CH/BLx/ERR

/CH/BLx/ESM/ERR

/CH/NEMx/ERR

Informational
OEM predictive failure deasserted.
Fan reporting Predictive Failure
petTrapFanPredictiveFailureAsserted
/CH/FMx/ERR

/CH/PSx/FAN_ERR

Major
Fan predictive failure is detected.
Fan Return to normal
petTrapFanPredictiveFailureDeasserted
/CH/FMx/ERR

/CH/PSx/FAN_ERR

Informational
Fan predictive failure state is cleared.
Voltage reporting Predictive Failure
petTrapVoltagePredictiveFailureAssertedAssert
/CH/PSx/V_3V3_ERR

/CH/PSx/Sx/V_IN_ERR

/CH/PSx/Sx/V_12V_ERR

Major
Voltagepredictive failure is detected.
Voltage Return to normal
petTrapVoltagePredictiveFailureDeassertedAssert
/CH/PSx/V_3V3_ERR

/CH/PSx/Sx/V_IN_ERR

/CH/PSx/Sx/V_12V_ERR

Informational
Predictive failure state due to voltage event has been cleared.
Temperature reporting Predictive Failure
petTrapTemperaturePredictiveFailureAsserted
/CH/PSx/TEMP_WRN

/CH/PSx/TEMP_ERR

Major
System is reporting a predictive failure as a result of high temperature.
Temperature Return to normal
petTrapTemperaturePredictiveFailureDeasserted
/CH/PSx/TEMP_WRN

/CH/PSx/TEMP_ERR

Informational
Predictive failure state due to high temperature has been cleared.
Fan Lower fatal threshold has been exceeded
petTrapFanLowerNonRecoverableGoingLow
/CH/PSx/FANx/TACH
Critical
Fan speed has decreased below lower non-recoverable threshold. Fan failed or removed.
Fan Lower fatal threshold no longer exceeded
petTrapFanLowerNonRecoverableGoingHighDeassert
/CH/PSx/FANx/TACH
Major
Fan speed has increased above lower non-recoverable threshold.
Voltage sensor ASSERT
petTrapVoltageStateAssertedAssert
/CH/PSx/Sx/V_OUT_OK
Informational
Voltage event has occurred.
Voltage sensor DEASSERT
petTrapVoltageStateDeassertedAssert
/CH/PSx/Sx/V_OUT_OK
Informational
Voltage event has occurred.
Current reporting Predictive Failure
petTrapCurrentPredictiveFailureAsserted
/CH/PSx/Sx/I_12V_ERR

/CH/PSx/Sx/I_12V_WRN

Major
Predictive failure due to electric current conditions.
Current Return to normal
petTrapCurrentPredictiveFailureDeasserted
/CH/PSx/Sx/I_12V_ERR

/CH/PSx/Sx/I_12V_WRN

Informational
Predictive failure caused by electric current conditions.