e-docs > Tuxedo > Messages > CMDTUX Catalog List > CMDTUX Messages 4200-4299 |
|
CMDTUX Messages 4200-4299
4206
WARN: The -L option is obsolete. Logging will go to the userlog
Description
In release 6.1 and earlier, the -L
option specified the log file for the tlisten process. In later releases, all logging goes to the userlog and this option is ignored.
Action
No action required.
See Also
tlisten
(1)
4207
ERROR: Could not become a background process
Description
Normally, the tlisten
process starts as a background program automatically. The program could not be restarted in the background and will not run.
Action
Check for other messages in the event log. Determine if there is an OS resource that is exhausted and re-try the command when it is resolved.
See Also
tlisten
(1)
4208
WARN: The -L option is obsolete
Description
In release 6.1 and earlier, the -L
option specified the log file for the tlisten process. In later releases, all logging goes to the userlog and this option is ignored.
Action
No action required.
See Also
tlisten
(1)
4209
INFO: Accepted request from fd, seq # number
Description
The tlisten
process will log the fact that it was able to accept a new connection, after successfully establishing a listening endpoint and opening an accept endpoint on the network. The listening endpoint connection descriptor, fd, and sequence number, number, are placed in the event log.
Action
No action required.
See Also
tlisten
(1)
4215
INFO: SRVID=srvid SRVGRP=grpname SIGTERM sent
Description
A SIGTERM signal was sent to a server in response to a "tmshutdown -w
" command or a TMIB request to set the server state to "DEAd
".
Action
No action required.
See Also
tmshutdown
(1), TM_MIB
(5)
4217
INFO: SRVID=srvid SRVGRP=grpname SIGKILL sent
Description
A SIGKILL signal was sent to a server in response to a "tmshutdown -w
" command or a TMIB request to set the server state to "DEAd
".
Action
No action required.
See Also
tmshutdown
(1), TM_MIB
(5)
4218
ERROR: Cannot send message to tlisten
Description
While trying to propagate the TUXCONFIG
to a non-master machine, a failure occurred in contacting the tlisten program.
Action
Check for other messages in either the local or remote event log.
See Also
tlisten
(1), TM_MIB
(5)
4219
ERROR: Cannot send message to tlisten
Description
While trying to propagate the TUXCONFIG
to a non-master machine, a failure occurred in contacting the tlisten
program.
Action
Check for other messages in either the local or remote event log.
See Also
tlisten
(1), TM_MIB
(5)
4221
ERROR: Cannot become a client - tpinit() failed - errmsg
Description
The administrative client sbbl
could not join the application
Action
There may be too many people attempting to perform MIB operations at the same time. Only 9 sbbl
servers may be run at a time, so that if there are more than 9 MIB operations which occur simultaneously, this message may appear. Limit the number of concurrent MIB operations.
4222
ERROR: Memory allocation failure
Description
The system ran out of memory in the sbbl process
Action
Make sure that the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
4223
ERROR: Cannot open file
Description
The sbbl
process has attempted to open its input file and failed
Action
If the host operating system has a limit on the number of open files, or the number of open files per user or the number of open files per process, then you may need to increase that limit. If it seems that there should be enough file descriptors for this operation, contact your BEA TUXEDO system Technical Support.
4224
ERROR: Cannot read from file
Description
The sbbl
process has attempted to read its input file and failed
Action
Contact your BEA TUXEDO system Technical Support.
4225
ERROR: Cannot open file
Description
While attempting to boot, the MIB has attempted to open a temporary output file and failed.
Action
If the host operating system has a limit on the number of open files, or the number of open files per user or the number of open files per process, then you may need to increase that limit. The file system /tmp
may be full. The directory where temporary files are placed may be full. If it seems that there should be enough file descriptors and disk space for this operation, contact your BEA TUXEDO system Technical Support.
4226
ERROR: Cannot write to file
Description
During a boot sequence, the MIB has attempted to write to its output file and failed.
Action
The file system /tmp
may be full. The directory where temporary files are placed may be full. If it seems that there should be enough disk space for this operation, contact your BEA TUXEDO system Technical Support.
4227
ERROR: Cannot open file
Description
While attempting to shutdown, the MIB has attempted to open a temporary output file and failed.
Action
If the host operating system has a limit on the number of open files, or the number of open files per user or the number of open files per process, then you may need to increase that limit. The file system /tmp may be full. The directory where temporary files are placed may be full. If it seems that there should be enough file descriptors and disk space for this operation, contact your BEA TUXEDO system Technical Support.
4228
ERROR: Cannot write to file
Description
During a shutdown sequence, the MIB has attempted to write to its output file and failed
Action
The file system /tmp
may be full. The directory where temporary files are placed may be full. If it seems that there should be enough disk space for this operation, contact your BEA TUXEDO system Technical Support.
4229
ERROR: Cannot allocate memory for tmconfig class attribute table
Description
Memory allocation failed while retrieving MIB attributes.
Action
Make sure that the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
4230
ERROR: tpcall() returned no configured class attribute for section fieldid
Description
While retrieving MIB attribute information, a failure occurred, so the tmconfig
operation will fail.
Action
Check the log for related messages.
4231
ERROR: tpcall() returned no class attribute entry for section fieldid
Description
While retrieving MIB attribute information, a failure occurred, so the tmconfig
operation will fail.
Action
Check the log for related messages.
4232
ERROR: Memory allocation failure
Description
While the sbbl
process was attempting to shut down a process, the system ran out of memory.
Action
Make sure that the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
4233
ERROR: Memory allocation failure
Description
While the sbbl
process was attempting to shut down a process, the system ran out of memory.
Action
Make sure that the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
4234
ERROR: Failed to get information on the Deactivated Object
Description
A failure occurred while the MIB was attempting to retrieve information about an object that was going to be deactivated.
Action
Contact your BEA TUXEDO system Technical Support.
4235
ERROR: Memory allocation failure
Description
While the sbbl
process was attempting to start a process, the system ran out of memory.
Action
Make sure that the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
4236
ERROR: Failed to get information on the Activated Object
Description
A failure occurred while the MIB was attempting to retrieve information about an object that was going to be activated.
Action
Contact your BEA TUXEDO system Technical Support.
4237
ERROR: Memory allocation error for TAGENT on site
Description
While attempting to generate an encryption packet for the TAGENT
on the given site, a memory allocation error occurred.
Action
Make sure that the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
4238
ERROR: No encryption package installed. num bits minimum encryption is configured
Description
A process attempted to contact the tlisten. However, the MINENCRYPTBITS
field in the NETWORK
section for this process was set to a value greater than 0. No encryption package is installed.
Action
Buy and install the Link Level Encryption package or reconfigure the system such that MINENCRYPTBITS
is 0.
4241
ERROR: Error receiving diffie-hellman reply from TAGENT on site
Description
The link level encryption packet which contained the Diffie-Hellman key exchange information was corrupted. The network may be compromised.
Action
Monitor your network for malicious use. Contact your BEA TUXEDO system Technical Support.
4242
WARN: Encryption negotiation failure with TAGENT on site
Description
The process attempting to connect to the TAGENT
could not successfully negotiate an encryption strength.
Action
There are many ways to fix this problem. One is to change the encryption parameters in the NETWORK
section for the connecting machine to be compatible with the options with which the remote tlisten was started. The second is to kill the remote tlisten, and restart it using different parameters for the -z
and -Z
options. If you do not specify any -z
or -Z
options to the tlisten
process, then by default it will speak any encryption protocol allowed in the currently installed package. To find out which package is installed on any site, run the command tmadmin
-v
. If your application is connecting to an older site, then you must configure the system such that it can speak 0 bits of encryption to the older site.
4243
ERROR: Error establishing diffie-hellman key
Description
The link level encryption packet which contained the Diffie-Hellman key exchange information was corrupted. The network may be compromised.
Action
Monitor your network for malicious use. Contact your BEA TUXEDO system Technical Support.
4244
WARN: Encryption negotiation failure with TAGENT on site
Description
The process attempting to connect to the TAGENT
could not successfully negotiate an encryption strength.
Action
There are many ways to fix this problem. One is to change the encryption parameters in the NETWORK
section for the connecting machine to be compatible with the options with which the remote tlisten was started. The second is to kill the remote tlisten, and restart it using different parameters for the -z
and -Z
options. If you do not specify any -z
or -Z
options to the tlisten process, then by default it will speak any encryption protocol allowed in the currently installed package. To find out which package is installed on any site, run the command tmadmin
-v
. If your application is connecting to an older site, then you must configure the system such that it can speak 0 bits of encryption to the older site.
4249
ERROR: Could not get encryption handle
Description
The system ran out of memory in the tlisten
process while attempting to allocate an encryption handle.
Action
Check the memory on the system where the command was run. If it seems that there should be enough memory for this operation, contact your BEA TUXEDO system Technical Support.
4252
ERROR: -z (sub) is larger than 0, but the link level package is not installed
Description
The -z
option was larger than zero. However, the link level encryption package was not installed.
Action
Buy the link level encryption package. Set the -z
option to 0. If you believe that you have installed the link level encryption package, contact your BEA TUXEDO system Technical Support.
4254
ERROR: Older client attempted to connect to secure tlisten
Description
A site older than the current release attempted to contact a tlisten
whose -z
option was set greater than 0.
Action
When older sites are part of a BEA TUXEDO configuration, the -z
option of the tlisten may have to be zero in order for proper communication between the older site and the newer site. By restarting the tlisten
process with a -z
option of zero (or no -z
option, since by default the minimum encryption parameter is zero), then older sites may successfully connect to this tlisten
process.
4255
ERROR: Could not generate first encryption packet
Description
The link level encryption packet which contained the Diffie-Hellman key exchange information was corrupted. The network may be compromised.
Action
Monitor your network for malicious use. Contact your BEA TUXEDO Technical Support.
4256
ERROR: Could not send first encryption packet
Description
An error occurred in the network when attempting to send an encryption packet.
Action
Check the network on the system where the tlisten
is running. If it seems that the network is working properly, contact your BEA TUXEDO Technical Support.
4257
ERROR: Encryption negotiation failure
Description
The process attempting to connect to the tlisten
could not successfully negotiate an encryption strength.
Action
There are many ways to fix this problem. One is to change the encryption parameters in the NETWORK
section for the connecting machine to be compatible with the options with which the remote tlisten was started. The second is to kill the remote tlisten, and restart it using different parameters for the -z
and -Z
options. If you do not specify any -z
or -Z
options to the tlisten
process, then by default it will speak any encryption protocol allowed in the currently installed package. To find out which package is installed on any site, run the command tmadmin -v
. If your application is connecting to an older site, then you must configure the system such that it can speak 0 bits of encryption to the older site.
4258
ERROR: fatal error while negotiating encryption parameters
Description
The link level encryption packet which contained the Diffie-Hellman key exchange information was corrupted. The network may be compromised.
Action
Monitor your network for malicious use. Contact your BEA TUXEDO system Technical Support.
4259
ERROR: Minimum encryption (num) is larger than 0, but the link level package is not installed
Description
The BRIDGE
or BSBRIDGE
could not boot because it was not configured correctly. The MINENCRYPTBITS
field in the NETWORK
section was set to a value greater than 0. No encryption package is installed.
Action
Buy and install the Link Level Encryption package or reconfigure the system such that MINENCRYPTBITS
is 0.
4261
ERROR: Memory allocation failure
Description
The system ran out of memory
Action
Make sure that the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
4262
ERROR: Could not create first diffie-hellman packet
Description
While generating the first link level encryption negotiation package for BRIDGE communication, an error occurred.
Action
Monitor your network for malicious use. Contact your BEA TUXEDO system Technical Support.
4263
ERROR: Error sending encryption negotiation packet
Description
While sending the first link level encryption negotiation package for BRIDGE communication, an error occurred.
Action
Check the network on the machine with the affected BRIDGE
or BSBRIDGE
.
4265
ERROR: Memory allocation failure
Description
The system ran out of memory in the BRIDGE
or BSBRIDGE
Action
Make sure that the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
4266
ERROR: Could not create second diffie-hellman packet
Description
While generating the second link level encryption negotiation package for BRIDGE
communication, an error occurred.
Action
Monitor your network for malicious use. Contact your BEA TUXEDO system Technical Support.
4267
ERROR: Error sending encryption negotiation packet
Description
While sending the second link level encryption negotiation package for BRIDGE
communication, an error occurred.
Action
Check the network on the machine with the affected BRIDGE
or BSBRIDGE
.
4268
ERROR: Encryption negotiation failed with bridge on site
Description
The BRIDGE
or BSBRIDGE
attempting to connect to the BRIDGE
or BSBRIDGE
on the given remote site could not successfully negotiate an encryption strength.
Action
Change the encryption parameters in the NETWORK
section for the two machines connecting to each other to be compatible.
4269
ERROR: System error during negotiation with bridge on site
Description
A system error occurred during link level encryption negotiation.
Action
Monitor your network for malicious use. Contact your BEA TUXEDO system Technical Support.
4271
ERROR: System error during negotiation with bridge on site
Description
A system error occurred during link level encryption negotiation.
Action
Monitor your network for malicious use. Contact your BEA TUXEDO system Technical Support.
4272
ERROR: Could not agree on encryption strength
Description
A system error occurred during link level encryption negotiation.
Action
Monitor your network for malicious use. Contact your BEA TUXEDO system Technical Support.
4274
ERROR: Could not send saved messages to site
Description
While the BRIDGE
or BSBRIDGE
is negotiating the link level encryption parameters, messages to the remote BRIDGE
are saved. An error occurred while sending these saved messages to the remote BRIDGE
after the negotiation was complete.
Action
Check the network on the machine with the affected BRIDGE
or BSBRIDGE
.
4275
ERROR: Cannot start servers, error reading *SERVERS section
Description
During the tmboot process, the SERVERS
section of the configuration file could not be read.
Action
Verify that the environment variable TUXCONFIG
is set correctly and exported. Make sure the TUXCONFIG
file is not corrupted (try a tmunloadcf
). Verify that the TUXCONFIG
file was propagated to all machines in the configuration.
See Also
tmboot
(1), tmunloadcf
(1)
4276
ERROR: Can't shutdown servers, error reading *SERVERS section
Description
During the tmshutdown process, the SERVERS
section of the configuration file could not be read.
Action
Verify that the environment variable TUXCONFIG
is set correctly and exported, or that TUXCONFIG
is not corrupted (try a tmunloadcf
)
4277
ERROR: Remote BBL boot failed. Try running pclean before booting
Description
A remote machine has been marked as partitioned, but has not been cleaned from the bulletin board using the tmadmin pclean
command (or the equivalent MIB operation).
Action
First pclean
the remote machine by using tmadmin
(or the GUI, or the MIB). Once the pclean
has completed successfully, try to boot the remote BBL again. If the remote boot fails again, contact your BEA TUXEDO system Technical Support.
4279
ERROR: Error detected during mutual authentication
Description
The tlisten
could not access the authentication files.
Action
Make sure that the administrator has read privileges on the $TUXDIR/udataobj/tlisten.pw
file or the $APPDIR/.adm/tlisten.pw
file. Monitor your network for malicious use. Contact your BEA TUXEDO system Technical Support.
4280
ERROR: Error detected during mutual authentication with val
Description
The remote tlisten
could not access the authentication files.
Action
Make sure that the administrator has read privileges on the $TUXDIR/udataobj/tlisten.pw
file or the $APPDIR/.adm/tlisten.pw
file on the remote site. Monitor your network for malicious use. Contact your BEA TUXEDO system Technical Support.
4281
ERROR: Cannot read password file "file" (errno=val)
Description
While authenticating with the tlisten
process, an error occurred while reading the password file
Action
The password file is $TUXDIR/udataobj/tlisten.pw
or $APPDIR/.adm/tlisten.pw
. Make sure that this file is not corrupted or missing. If everything in the file appears normal, contact your BEA TUXEDO system Technical Support.
4282
ERROR: Failed to change working directory to "dir" (errno = val)
Description
The tlisten
process may attempt to change directories to $APPDIR
during authentication. If the process cannot change directories, this error may occur.
Action
Make sure that the APPDIR
of the current application is not corrupted or missing. If everything in the directory appears normal, contact your BEA TUXEDO system Technical Support.
4283
ERROR: Failed to determine file length for "dir" (errno = val)
Description
While authenticating with the tlisten
process, an error occurred while reading the password file.
Action
The password file is $TUXDIR/udataobj/tlisten.pw
or $APPDIR/.adm/tlisten.pw
. Make sure that this file is not corrupted or missing. If everything in the file appears normal, contact your BEA TUXEDO system Technical Support.
4284
ERROR: Authentication requested, but no password file exists
Description
While authenticating with the tlisten process, an error occurred while reading the password file.
Action
The password file is $TUXDIR/udataobj/tlisten.pw
or $APPDIR/.adm/tlisten.pw
. Make sure that this file is not corrupted or missing. If everything in the file appears normal, contact your BEA TUXEDO system Technical Support.
4285
WARN: T L I S T E N A U T H E N T I C A T I O N I S D I S A B L E D !
Description
tlisten authentication has been turned off. No site will be authenticated. Be warned that the tlisten may be the site of a security breach.
Action
The password file is $TUXDIR/udataobj/tlisten.pw or $APPDIR
/.adm/tlisten.pw. The password file is a plain-text file where each line (up to 20) contains a password. The password file on the remote site must contain at least one password which is the same as a password on the local site. If you create this file, and restart the tlisten or other process which may have to speak to the tlisten, then this warning will not be displayed. If this warning is not displayed, then the network session with the remote site will be authenticated.
4286
ERROR: Password file "file" exists, encryption is not available
Description
In order to properly authenticate the tlisten session, an encryption package must be installed.
Action
Contact your BEA TUXEDO system Technical Support.
4287
ERROR: Failed to open password file "file" (errno = val)
Description
The system found the tlisten
authentication password file, but could not open it.
Action
If the host operating system has a limit on the number of open files, or the number of open files per user or the number of open files per process, then you may need to increase that limit. If it seems that there should be enough file descriptors for this operation, contact your BEA TUXEDO system Technical Support.
4288
WARN: More than val passwords found in file
Description
The tlisten
authentication file will only accept the first twenty passwords. All subsequent passwords will be ignored.
Action
Limit the number of passwords in the tlisten
password authentication file to twenty.
4289
WARN: Password #val is greater than val chars
Description
Passwords found in the tlisten
authentication file can only be the specified number of characters long. All characters after the maximum number of characters will be ignored.
Action
Limit the number of characters for each password in the tlisten
password authentication file to the specified amount.
4290
ERROR: No passwords in password file
Description
There must be at least one password in the password authentication file in order for tlisten
authentication to work properly.
Action
The password file is $TUXDIR/udataobj/tlisten.pw
or $APPDIR/.adm/tlisten.pw
. Add a password to the password file. One suggestion for a password is abracadabra
.
4291
ERROR: S E C U R I T Y V I O L A T I O N ! Remote site may be compromised.
Description
The remote site did not have a matching password in its password file.
Action
Make sure that there is a password on the local site which matches one of the passwords on the remote site. Monitor your network for malicious use. Contact your BEA TUXEDO system Technical Support.
4292
ERROR: Transport failure during authentication
Description
The network returned an error during authentication with the tlisten.
Action
Check the network on the system where the command was run. If the network is OK, contact your BEA TUXEDO system Technical Support.
4293
ERROR: Failed to authenticate with remote process (tperrno=val)
Description
Authentication with the remote tlisten
failed.
Action
Make sure that there is a password on the local site that matches one of the passwords on the remote site. Monitor your network for malicious use. Contact your BEA TUXEDO system Technical Support.
4294
ERROR: Invalid protocol message received during authentication
Description
Authentication with the remote tlisten
failed.
Action
Monitor your network for malicious use. Contact your BEA TUXEDO system Technical Support.
4295
ERROR: Invalid protocol message received during authentication
Description
Authentication with the remote tlisten
failed.
Action