System FRU Component NAC Names
This table lists and describes the System FRU (field replaceable unit) Component NAC (nomenclature architecture council) names, and identifies the IPMI type and values.
Name (8-Socket 1x8) | System A Name (Dual 4-Socket 2x4-A Side) | System B Name (Dual 4-Socket 2x4-B Side) | Description |
---|---|---|---|
/SYS |
/SYS |
/SYS |
System FRU |
/SYS/UUID |
/SYS/UUID |
/SYS/UUID (unique, different from A side) |
Unique System ID (hidden) |
/SYS/PS[0-3] |
/SYS/PS[2-3] |
/SYS/PS[0-1] |
Power Supplies (Static FRUID) |
/SYS/FM[0-7] |
/SYS/FM[0-3] |
/SYS/FM[4-7] |
Fan Modules (No FRUID) |
/SYS/SMOD[0-1]/HDD[0-3] |
/SYS/SMOD0/HDD[0-3] |
/SYS/SMOD1/HDD[0-3] |
Hard Disk Drives |
/SYS/MIDPLANE |
/SYS/MIDPLANE |
/SYS/MIDPLANE |
System Chassis Midplane (Dynamic FRUID) |
/SYS/SMOD[0-1] |
/SYS/SMOD0 |
/SYS/SMOD1 |
System Module |
/SYS/SMOD[0-1]/DBP |
/SYS/SMOD0/DBP |
/SYS/SMOD1/DBP |
Disk Backplanes (Dynamic FRUID) |
/SYS/SMOD[0-1]/MB |
/SYS/SMOD0/MB |
/SYS/SMOD1/MB |
System Module (Dynamic FRUID) |
/SYS/SMOD[0-1]/MB/NET[0-3] |
/SYS/SMOD0/MB/NET[0-3] |
/SYS/SMOD1/MB/NET[0-3] |
System Host Network Interfaces (Static FRUID) |
/SYS/SMOD[0-1]/MB/BIOS |
/SYS/SMOD0/MB/BIOS |
/SYS/SMOD1/MB/BIOS |
System BIOS |
/SYS/SMOD[0-1]/MB/CPLD |
/SYS/SMOD0/MB/CPLD |
/SYS/SMOD1/MB/CPLD |
CPLD on System Module |
/SYS/SMOD[0-1]/HBA |
/SYS/SMOD0/HBA |
/SYS/SMOD1/HBA |
HBA |
/SYS/SMOD[0-1]/MB/SP |
/SYS/SMOD0/MB/SP |
/SYS/SMOD1/MB/SP |
Embedded Service Processor on System Module (Dynamic FRUID) |
/SYS/SMOD[0-1]/MB/SP/NET[0-1] |
/SYS//SMOD0/MB/SP/NET[0-1] |
/SYS/SMOD1/MB/SP/NET[0-1] |
Service Processor network interfaces |
/SYS/CMOD[0-7] |
/SYS/CMOD[0-3] |
/SYS/CMOD[4-7] |
CPU Module. 8 CMODs per chassis (Dynamic FRUID) |
/SYS/CMOD[0-7]/P[0-7] |
/SYS/CMOD[0-3]/P[0-3] |
/SYS/CMOD[4-7]/P[4-7] |
CPU on CPU Module Motherboard (Static FRUID) |
/SYS/CMOD[0-7]/P[0-7]/D[0-11] |
/SYS/CMOD[0-3]/P[0-3]/D[0-11] |
/SYS/CMOD[4-7]/P[4-7]/D[0-11] |
DIMMs on CPU Module Motherboard (Dynamic FRUID) |
/SYS/CMOD[0-7]/CPLD |
/SYS/CMOD[0-3]/CPLD |
/SYS/CMOD[4-7]/CPLD |
CPLD on CPU Module |
/SYS/DPCC[0-7] |
/SYS/DPCC[0-3] |
/SYS/DPCC[4-7] |
Dual PCIe Card Carrier |
/SYS/DPCC[0-7]/PCIE[1-16] |
/SYS/DPCC[0-3]/PCIE[1-8] |
/SYS/DPCC[4-7]/PCIE[9-16] |
PCIe Cards 1-16 |
/SYS/FIM |
/SYS/FIM |
/SYS/FIM |
Front Indicator Module. not exposed by ILOM |