Power Management State Changes
The following table describes the scenarios in which the power management state changes for the Express Station 4 Series.
Table 5-1 Power Management State Changes
Starting State | Event | Resulting State |
---|---|---|
Unplugged |
AC power is connected to a wall outlet and the last recorded power state was not the ON state. |
NOPOWER |
NOPOWER |
The operator presses the power button for less than 1 second. |
ON |
NOPOWER |
The operator presses the power button for more than 4 seconds. |
ON |
NOPOWER |
A server application sends a Wake On LAN command. |
ON |
NOPOWER |
AC power fails and then is restored. |
NOPOWER* |
ON |
The operator presses the power button for less than 1 second. |
NOPOWER** |
ON |
The application shuts down the Express Station. |
NOPOWER |
ON |
The Client Application Loader sends a Restart command. |
NOPOWER and then ON |
ON |
AC power fails and then is restored. |
ON* |
*Based on the default BIOS power settings.
**Microsoft Windows: Pressing the power button begins a graceful shutdown. This behavior is based on the Windows power button management setting. Oracle Linux for MICROS: Pressing the power button initiates a graceful shutdown, but shutdown may take up to 10 seconds to complete.
Parent topic: Power Management States