Offline Configuration Spreadsheet Template
The first step in deploying a bulk device cluster is generating an offline configuration spreadsheet template.
To generate a spreadsheet template, you select an existing offline
config from the
Offline
Config page and the OCSDM takes all of the headers and bind
variables from this offline configuration and puts them into the generated
template.
Note:
If the offline configuration from which you generated your template is changed after you have created your spreadsheet, you must regenerate the template. Anytime a change is made to an offline configuration, the OCSDM performs validation checks on all associated spreadsheets and marks any spreadsheets invalid that fail. When you generate a template, the OCSDM automatically names the file
using the following format:
OfflineConfigName_<SoftwareVersion>_<Platform>_<Timestamp>
You can change the template name when you save the file.
When you generate a template, the spreadsheet's top two rows are filled
in automatically, with the first row containing the details of the Software,
platform, and schema of the offline configuration in the following format:
Offline Config, <Offline Config Name>, Software version, <Software version of the Offline Config>, Platform, <Platform of the Offline Config>, Schema name <Schema name of the offline config>
The second row's header fields are generated depending on whether this
is a SNMP v1v2 device or a SNMPv3 device. The following header rows appear in
the second row, separated by commas, for an SNMPv1v2 device:
Header | Description | Required? |
---|---|---|
Device name | The name of the device to be added. | Yes |
Primary IP address | The primary IP address of the device; this value must be a valid IP address. | Yes |
Secondary IP address | The secondary IP address of the device; this value must be a valid IP address. | No |
Username | The username for accessing the device. | Yes |
Password | The password for accessing the device. | Yes |
SNMP Port | The port for SNMP access; this must be a valid port and must be a numeric value. | Yes |
SNMP Community | The SNMP community name present on the device; this must be a valid SNMP community and must contain a valid SDM IP address. | Yes |
Synchronized mode | Indicates if the device is powered by the original offline configuration; this may be true or false. | No; the OCSDM uses the value configured at the cluster level |
Bind variable ..<n> Name | Corresponds to the bind variables for the selected offline configuration; this value must be of the same type. | No |
The following header rows appear in the second row, separated by commas,
for an SNMP v3 device:
Header | Description | Required? |
---|---|---|
Device name | The name of the device to be added. | Yes |
Primary IP address | The primary IP address of the device; this value must be a valid IP address. | Yes |
Secondary IP address | The secondary IP address of the device; this value must be a valid IP address. | No |
Username | The username for accessing the device. | Yes |
Password | The password for accessing the device. | Yes |
SNMP Port | The port for SNMP access; this must be a valid port and must be a numeric value. | Yes |
SNMPv3 username | The SNMPv3 username. | Yes |
SNMPv3 Authentication protocol | SNMPv3 authentication protocol:
|
Yes |
SNMPv3 Authentication password | The SNMPv3 authentication password. | No |
SNMPv3 privacy protocol | The SNMPv3 privacy protocol:
|
Yes |
SNMPv3 privacy password | The SNMPv3 privacy password | No |
Synchronized mode | Indicates if the device is powered by the original offline configuration; this may be true or false. | No; the OCSDM uses the value configured at the cluster level |
Bind variable ..<n> Name | Corresponds to the bind variable for the offline configuration; this value must be of the same type. | No |