system-config > collect > group-settings

The group-settings subelement allows you to configure and modify collection parameters for specific groups.

Parameters

group-name
Enter the name of the object the configuration parameters are for. There can only be one object per group.
  • Values:
    • system
    • interface
    • session-agent
    • session-realm
    • voltage
    • fan
    • temperature
    • sip-sessions
    • sip-ACL-oper
    • sip-ACL-status
    • sip-client
    • sip-server
    • sip-policy
    • sip-errors
    • sip-status
    • sip-invites
    • sip-rate
    • sip-rate-per-inf
    • sip-rate-per-agent
    • sip-srvcc (Only supported for enterprise products)
    • sip-codec-per-realm
    • enum-stats
    • enum-rate
    • enum-rate-per-name
    • enum-rate-per-addr
    • dnsalg-rate
    • dnsalg-rate-per-realm
    • dnsalg-rate-per-addr
    • h323-stats
    • ike-stats
    • radius-stats
    • diameter-stats
    • msrp-stats
    • dos-threshold-counters
    • stir-stats
    • stir-stats-session-agent
    • stir-stats-sip-interface
    • stir-stats-realm
    • stir-stats-system
    • network-util
    • space
    • registration-realm
    • thread-usage
    • thread-event
    • survivability-sip-errors (Only supported for enterprise products)
    • survivability-sip-status (Only supported for enterprise products)
    • survivability-sip-invites (Only supported for enterprise products)
    • survivability-sip-registration (Only supported for enterprise products)
    • sobjects
    • ext-rx-policy-server
    • sa-ike
    • sa-imsaka (Only supported for enterprise products)
    • sa-srtp
    • xcode-session-gen-info
    • xcode-codec-util
    • xcode-tcm-util
    • sip-method
    • sip-realm-method
    • sip-interface-method
    • sip-agent-method
    • latest-peak-license-usage
sample-interval
Enter the group data collection sampling interval, in minutes
  • Default: 5
  • Values: Min: 1 / Max: 120
start-time
Enter the date and time to start group data collection. Enter in the form of: yyyy-mm-dd-hh:mm:ss (y=year; m=month; d=day; h=hour; m=minute; s=second)
  • Default: now
  • Values:
    • now - Start data collection now.
    • <date&time> - Date and time to start data collection.
end-time
Enter the date and time to stop group data collection. Enter in the form of: yyyy-mm-dd-hh:mm:ss (y=year; m=month; d=day; h=hour; m=minute; s=second)
  • Default: never
  • Values:
    • never - Never end data collection .
    • <date&time> - Date and time to end data collection.
boot-state
Enable or disable data collection for this group.
  • Default: disabled
  • Values: enabled | disabled

Path

group-settings is a subelement of the configure terminal > system > system-config > collect > subelement. The full path from the topmost ACLI prompt is: configure terminal > system > system-config > collect > group-settings