Known Issues

The following table lists the known issues in this release. You can reference known issues by Service Request ID number and you can identify the issue, any workaround, when the issue was found, and when it was fixed using this table. Issues not carried forward in this table from previous Release Notes are not relevant to this release. You can review delivery information, including defect fixes in the S-Cz9.2.0 Build Notes.

ID Description Severity Found In
37431006 After running the restore-backup-config command, you must reboot your system to make sure all the non-RTC configurations are applied properly. Post that the traffic should be started. 3 S-Cz10.0.0
34991934 Do not upgrade any device licensed to use FIPS to S-Cz9.2.0. This causes the system to fail, preventing successful boot. 3 S-Cz9.2.0
35038085 If an exiting audio stream is interrupted by a stray SSRC within the flow's packets, this interruption may trigger one-way audio wherein the audio towards the called party fails. You can confirm this condition by locating RTP packets in the flow with stray SSRC. 2 S-Cz9.1.0
33600407 When you add IPv4 and IPv6 addresses consecutively on the hip-ip-list and icmp-address of the same network-interface, followed by save and activate, the system eventually activates the configuration change but the SBC goes into an unsteady state with the following events on the console:

unregister_netdevice: waiting for <interface:id> to become free.Usage count = 1.

Workaround: Add IPv4 and IPv6 address on the hip-ip-list and icmp-address separately and activate them individually. For example, activate the first config change or addition and then add and activate the second configuration change.

2 S-Cz8.4.0
32077115 For Hairpin and Spiral call scenarios, the hide-egress-media-update parameter under media-sec-policy is not supported.

In addition, you must reboot the SBC when you change the hide-egress-media-update parameter under the media-sec-policy, inbound subelement. This parameter is not RTC supported.

Oracle recommends you use the hide-egress-media-update parameter under the realm-config only.

3 S-Cz9.0.0
32565921 The acquire-config process is unsuccessful when your configuration includes an acp-tls-profile. The system does successfully synch the profile after establishing HA.

Workaround: Disable your acp-tls-profile on the active system before performing an aquire-config procedure. Re-enable the profile after aquire-config completes successfully.

3 S-Cz9.0.0
None This version does not support the enhancement to SMP-Aware Task Load Limiting, which adds a second parameter to the sip-config load-limit option. N/A S-Cz7.4.0

26790731

Running commands with very long output, such as the "show support-info" command, over an OVM virtual console might cause the system to reboot.

Workaround: You must run the "show support-info" command only over SSH.

2 S-Cz8.0.0

None

Re-balancing is unavailable on the OCSLB when running an Acme Packet 6300 as a cluster member. Set the SLB cluster-config, auto-rebalance parameter to disabled to use an Acme Packet 6300 as a cluster member from that SLB. N/A S-Cz730

None

The system does not support SIP-H323 hairpin calls with DTMF tone indication interworking. N/A S-CZ720

None

The SBC stops responding when you configure an H323 stack supporting SIP-H323-SIP calls with the max-calls parameter set to a value that is less than the q931-max-calls parameter.

Workaround: For applicable environments, configure the H323 stack max-calls parameter to a value that is greater than its q931-max-calls parameter.

N/A S-CZ7.4.0
None The system does not support HA Redundancy for H.323 calls. N/A N/A

27699451

Oracle qualified the QSFP interface for the OCSR operating over the Oracle X7-2 platform for a single QSFP port operating in 4-port mode. Specifically, 4 media interfaces successfully map to the second port of the QSFP interface using a Hydra cable as physical connections to 10G switch ports. 3 S-Cz8.1.0

26316821

When you configure the 10 second QoS update mechanism for OCOM, the SBC presents the same codec on both sides of a transcoding call in the monitoring packets.

You can determine the correct codecs from the SDP in the SIP Invite and 200 OK.

3 S-Cz8.0.0p1
The SBC dead peer detection does not work with IKEv1. 3 S-Cz8.4.0
28539190 When operating as a VNF and using Mellanox interface cards, the OCSBC does not use the Host In Path (HIP) configuration to restrict management traffic, Instead the system allows any traffic over the interface. 3 S-Cz8.2.0
28617865 This version of the OCSBC is not supported as a VNF over VMware using Mellanox interface cards. 3 S-Cz8.2.0
29170419 In long call scenarios, the SBC does not send the expected refresh before the Session-Expires: header value time is up for SUBSCRIBE messages. 2 S-Cz8.2.0

30643522

Starting with S-Cz8.3.0m1p2, Lawful Intercept users cannot modify LI configuration with the Session Delivery Manager.

Workaround: LI Configuration must be performed through the ACLI.

4 S-Cz8.3.0m1p2
34267143 No left-side Index and search in the browser for local Help files. 4 S-CZ9.1.0