bfd-config > bfd-session
The bfd-session configuration element is used for configuring individual BFD sessions.
Parameters
- bfd-sess-type
- Specifies the type for this specific session. 
                        - Default: primary
- Values: vip/primary/secondary
 
- admin-state
- Specifies whether this specific session is enabled. 
                        - Default: disabled
- Values: enabled/disabled
 
- admin-session-state
- Allows you to put this specific session in admin-down state. 
                        - Default: adminDown
- Values: up/adminDown
 
- min-tx-interval
- Specifies the min-tx-interval in milleseconds. Refer to RFC
						5880 for more details. 
                        - Default: 1000
- Values: 1 - 65535
 
- min-rx-interval
- Specifies the min-rx-interval in milleseconds. Refer to RFC
						5880 for more details. 
                        - Default: 1000
- Values: 1 - 65535
 
- detect-multiplier
- Specifies the detect-multipler as an integer. Refer to RFC 5880
						for more details. 
                        - Default: 3
- Values: 1-255
 
- hold-down-time
- Specifies the duration, in milliseconds, after which an up transition is
						reported to the application to prevent rapid state flapping. 
                        - Default: 0 (disabled)
- Values: 0-10000
 
- local-discriminator
- Specifies the integer used by the system to identify this
						session. Values range from 1 - 4294967295. 
                        - Default: 3
- Values: 1-4294967295
 
Path
bfd-session is an element under the network-interface path. The full path from the topmost prompt is: