Known Issues
This table lists the known issues in version S-Cz8.3.0. You can reference known issues by Service Request number and you can identify the issue, any workaround, when the issue was found, and when it was fixed using this table. Issues not carried forward in this table from previous Release Notes are not relevant to this release. You can review delivery information, including defect fixes in this release's Build Notes.
ID | Description | Severity | Found In | |
---|---|---|---|---|
31373813 | If upgrading TO any of
the following releases FROM any prior release and you have IPSEC or
IMS-AKA enabled and are configured in an HA configuration, an
In-Service upgrade is not supported.
|
3 | SCZ830m1p5 | |
30611784 |
When executing a GET ALL procedure
using the REST interface, the OCSBC fails over. The GET method does
not produce results until the Standby server becomes Active.
Customer Impact: Customer will not be able to get any response(including 200 empty response) from OCSBC when he tries to retrieve configuration of any element using GET method. |
3 | SCZ830m1p2 | |
29403076 |
When generating HDR reports and SNMP output on resource utilization that includes threads, the OCSBC omits the thread name, leaving the applicable field and OID empty. | 3 | SCZ810M1P9 | |
29913123 |
NMC causes the Acme Packet 6350 to failover when NMC gets its first traffic match. | 2 | SCZ810M1P9 | |
29881449 |
The DSP used by the OCSBC has a vendor firmware defect that causes failures with the T.38 codec. If you are using the T.38 codec, you may experience minimal media losses on those calls. This problem may also, however, cause the OCSBC to reboot. Oracle is acquiring a firmware fix from the DSP vendor. |
3 | SCZ810m1p9 | |
30330778 |
The OCSBC cannot forward a call that uses a TEL-URI and includes the routing number (rn) parameter. Depending on your routing configuration, the OCSBC may reject these call with a 404 Not Found/No Route to Destination. The OCSBC forwards these portability scenarios properly when they present an R-URI. | 1 | SCZ740m2p4;810m1p18 | |
29846828 |
The OCSBC stops generating registration refreshes after 12 hours for Surrogate Agents. After a reboot, the OCSBC attends to registration and refreshes correctly using the new Call ID for 12 more hours. | 2 | ECZ810m1p8 | |
30444535 |
When configured for the minimum TCP disconnect time, the default for network-parameters, the OCSBC takes an unexpectedly long time before attempting to create a socket and connect. When using the defaults to create and connect using the minimum amount of time, this process takes 18 seconds instead of 9. | 3 | ||
30158557 |
Under high media loads that include AMR/AMR-WB to PCMA transcoding, the 10G port on the Acme Packet 6300 is experiencing packet loss and, therefore media MOS degradation. | 2 | SCZ810m1p16 | |
29862440 |
When transcoding from T.38 to G711FB, the OCSBC includes mutiple (for example 2) m-lines in the SDP when there are multiple (for example 2) c-lines in the source SDP. This happens even if you have set the fax-single-m-line parameter in the applicable codec-policy to present a single m-line. Workaround: Configure an ingress HMR to remove all but 1 c-line from the incoming SDP. |
3 | SCZ740m1p8 | |
30364057 |
Do not use DNS for
multiple services on the OCSBC simultaneously. DNS service operates
on the OCSBC normally when you configure it for a single purpose.
When you configure it for multiple purposes, however, lookups do not
complete correctly.
Workaround: An example of this would be configuring DNS for both PCRF and ENUM services. You can mitigate this issue by configuring the local routing table with ENUM lookups. |
3 | SCZ830p7 | |
30612465 |
On Virtual platforms, the OCSBC is not forwarding traffic transcoded to EVS or Opus codecs if you have configured the applicable policy with a forced ptime of 60ms. | 3 | SCZ830m1p2 | |
30520108 |
Upon registering 100k or more IMS-AKA user registrations, and handling large numbers of VoLTE calls and registration refreshes, in excess of 8k for example, a vSBC may hang. At this point, you would find the vSBC unresponsive and inaccessible. An example of conditions when this may occur includes:
Reboot the system from the hypervisor to recover from this issue. |
|||
30520181 |
When performing large numbers of simultaneous registrations, such as during a registration flood, the OCSBC may become unstable and crash when it exceeds 200k IMS-AKA subscriber registrations. |
|||
None | This version's enhancement to SMP-Aware Task Load Limiting, which adds a second parameter to the sip-config load-limit option, is currently not supported. | N/A | SCZ740 | |
24574252 |
The show interfaces brief command incorrectly shows pri-util-addr information in its output. | 3 | SCZ740 | |
26790731 |
Running commands with
very long output, such as the "show support-info" command, over an
OVM virtual console might cause the system to reboot.
Workaround: You must run the "show support-info" command only over SSH. |
2 | SCZ800 | |
26338219 | The packet-trace remote command does not work with IPv6. | 2 | SCZ740 | |
26497348 |
When operating in HA mode, the OCSBC may display extraneous "Contact ID" output from the show sipd endpoint-ip command. You can safely ignore this output. | 3 | SCZ800 | |
26598075 |
When running on the Acme Packet 4600, the OCSBC sends a 200OK with IPv4 media address for call flows with offerless INVITES and the OCSBC configured with add-sdp-invite=invite and ALTC configured for IPv6 on the egress. | 3 | SCZ800 | |
26559988 |
In call flows that include dual ALTC INVITEs from the callee, and subsequent Re-INVITEs that offer an ALTC with IPv6 video, the OCSBC may not include the m lines in the SDP presented to the end stations during the Re-INVITE sequence. This results in the call continuing to support audio, but not video. | 3 | SCZ800 | |
None |
Re-balancing is unavailable on the OCSLB when running an Acme Packet 6300 as a cluster member. Set the SLB cluster-config, auto-rebalance parameter to disabled to use an Acme Packet 6300 as a cluster member from that SLB. | N/A | SCZ730 | |
24809688 |
Media interfaces configured for IPv6, and using different VLANs that operate over different infrastructures, including VoLTE and 3GPP, are not supported. | 3 | SCZ730 | |
None |
The system does not support SIP-H323 hairpin calls with DTMF tone indication interworking. | N/A | S-CZ720 | |
None |
The OCSBC stops
responding when you configure an H323 stack supporting SIP-H323-SIP
calls with the max-calls parameter set to a value that is less
than the q931-max-calls parameter.
Workaround: For applicable environments, configure the H323 stack max-calls parameter to a value that is greater than its q931-max-calls parameter. |
N/A | S-CZ740 | |
None | The system does not support HA Redundancy for H.323 calls. | N/A | N/A | |
23756306 |
When you configure the session-router with an operation-mode of session, it does not correctly clear sessions. |
3 | S-Cz7.2.0 | |
23253731 |
After an HA switchover, the new standby OCSBC retains some IMS-AKA subscriber TCP sockets. You can clear these sockets by rebooting the OCSBC. | 2 | SCZ730M2 | |
27699451 |
Oracle qualified the QSFP interface for the OCSR operating over the Oracle X7-2 platform for a single QSFP port operating in 4-port mode. Specifically, 4 media interfaces successfully map to the second port of the QSFP interface using a Hydra cable as physical connections to 10G switch ports. | 3 | SCZ810 | |
27911939 |
When running the OCSBC over the KVM hypervisor and using SR-IOV interface mode, the system fails over when all of following conditions are in effect:
|
3 | SCZ810 | |
28618563 |
The system is not populating the Username AVP in Accounting Requests (ACRs) correctly. When triggered by an INVITE, these AVPs contain only the "@" sign. They do not include the username and domain name portion of the URL. | 3 | CZ810m1 | |
26316821 |
When configured with the 10 second QoS update mechanism for OCOM, the OCSBC presents the same codec on both sides of a transcoding call in the monitoring packets. You can determine the correct codecs from the SDP in the SIP Invite and 200 OK. |
3 | SCZ8.0.0p1 | |
26323802 |
The 10s QoS interim feature includes the wrong source IP address as the incoming side of a call flow. The issue does not prevent successful call and QoS monitoring. For monitoring and debugging purposes, you can find the source IP in the SIP messages (INVITE/200OK). |
3 | SCZ8.0.0p1 | |
26669090 |
The OCSBC dead peer detection does not work with IPv4. | 3 | SCZ8.0.0 | |
27031344 |
When configured to perform SRTP-RTP interworking, the OCSBC might forward SRTP information in the SDP body of packets on the core side, causing the calls to terminate. Workaround: Add an appropriately configured media-sec-policy on the RTP side of the call flow. This policy is in addition to the policy on the SRTP side of the call flow. |
3 | SCZ8.0.0p1 | |
28539190 | When operating as a VNF and using Mellanox interface cards, the OCSBC does not use the Host In Path (HIP) configuration to restrict management traffic, Instead the system allows any traffic over the interface. | 3 | SCZ820 | |
28617865 | This version of the OCSBC only is not supported as a VNF over VMware using Mellanox interface cards. | 3 | SCZ820 | |
28639227 | When operating as a VNF and using Mellanox interface cards, the OCSBC does not support SCTP transport. | 3 | SCZ820 | |
28658810 | When operating as a VNF and using Mellanox interface cards, the OCSBC does not support any other type of card for media interfaces. (If any media interface uses a Mellanox card, all media interfaces must use a Mellanox card.) | 3 | SCZ820 | |
28748784 | When operating as a VNF and using Mellanox interface cards, the OCSBC does not support outbound ICMP. | 3 | SCZ820 | |
28819431 | For TSM use case, the ETC CPU load increased 40% over the previous release. | 2 | SCZ820 | |
28906914 | For transcoding use cases, the G711/G729 codec pair might experience unstable performance when each DSP has greater than 500 transcoding sessions. | 3 | SCZ820 | |
29005944 | On Acme Packet hardware in an HA configuration, with a large number of IMS-AKA endpoints, the standby is unable to synchronize, and when rebooted goes OOS. | 3 | SCZ820 | |
28999116 | IWF (SIP-H323) appears at the setup entitlements prompt on virtual platforms when H.323 is not supported. | 3 | SCZ820 | |
28770472 | ACLI Users will receive an error on the output of the show registration sipd by-user command. | 4 | SCZ820 | |
29170419 | In long call scenarios, the SBC is not sending the expected refresh before the Session-Expires: header value time is up for SUBSCRIBE messages. | 2 | SCZ820 | |
29546194 | The SBC is unable to maintain 400 or more TSM/DTLS tunnels. | 2 | SCZ830 | |
The Acme Packet 6350 with Quad 10Gbe NIU is unable to maintain 375,000 or more idle TSM/DTLS tunnels. | 3 | SCZ830p2 | ||
29999832 and 30194470 |
When deployed as a vSBC, configured for IMS-AKA, and operating with registrations exceeding 60k, the OCSBC may exhibit performance degradation, exhibited by high CPU load or system crash. Workaround - Oracle has found that disabling the security-policy sa-lookup-exception parameter allows IMS-AKA to function correctly while supporting a high number of registrations. This parameter is enabled by default. Disable this parameter within all applicable security policies before running IMS-AKA. This parameter, when enabled on Acme Packet hardware, works as designed. |
3 | SCZ830 | |
30643522 |
Starting with
S-Cz8.3.0m1p2, Lawful Intercept users cannot modify LI configuration
with the Session Delivery Manager.
Workaround: LI Configuration must be performed through the ACLI. |
4 | SCZ830m1p2 |
Resolved Known Issues
ID | Description | Severity | Found In | Fixed In | |
---|---|---|---|---|---|
32535426 |
The show
temperature output will display different values compared to
releases older than S-Cz8.3.0. Starting with S-Cz8.3.0, the
temperature queries via ACLI and SNMP are reporting more
accurate values.
Note: Similar components may not correspond between different platforms due to physical differences in each system. |
3 | SCZ810 | SCZ830 | |
28157960 |
When setting up a SIPREC session, the SBC sets up 1-way audio if the far end offers an odd port number in the m line. | 2 | SCZ800 | SCZ830m1p8 | |
29779932 |
The OCSBC uses a Diffie Hellman algorithm that conflicts with that of the 10.4 Solaris SFTP server. As a result, both CDR and HDR transfers to these servers fail. Do not use the Solaris 10.4 SFTP server with the OCSBC. |
1 | SCZ830p7 | SCZ830m1p5 | |
30611784 |
When executing a
GET ALL procedure using the REST interface, the OCSBC fails
over. The GET method does not produce results until the Standby
server becomes Active.
Customer Impact: Customer will not be able to get any response(including 200 empty response) from OCSBC when he tries to retrieve configuration of any element using GET method. |
3 | SCZ830m1p2 | SCZ830m1p5 | |
29931732, 31089996 |
The embedded communications monitor probe does not send IPv6 traffic to the Oracle Communications Operations Monitor's mediation engine. | 3 | SCZ800 | SCZ830m1p9 | |
31039820 | When mid-call Lawful Intercept is enabled, and the SBC has not started intercepting particular sessions, those sessions will not be replicated on the standby. If a switchover occurs, affected calls could be dropped. | 3 | SCZ830m1p2 | SCZ830m1p9 | |
31188777 |
The SBC does not provide support for P-Acme-Playback header when 'direction=both'. | 3 | SCZ830 | SCZ830m1p9 | |
30375697 | Infrequently during race conditions, the number of SIP registration entries on the active and standby SBCs differs, with the standby SBC containing less entries. When this happens and a failover occurs, some endpoints are unable to receive calls until the endpoint re-registers. Increase Journal index size and optimize the Journal management code to avoid this. | 2 | S-Cz8.1.0m1p18 | S-Cz8.1.0m1p18b | |
30544663 | When a session
add action is executed and the session is not found in the sipProxy, a new Sip
Session and two Sip Dialogs are created and cross referenced and the buffer
from the active is loaded. If the load fails, the update function exits and the
SipSession and SipDialogs are left dangling and create a memory leak.
Workaround: To avoid this memory leak, successfully load the buffer BEFORE creating the session and dialogs. Monitor the standby SBC's memory usage and reboot as needed. |
3 | S-Cz8.1.0m1 | S-Cz8.1.0m1p18b | |
30498837 | A sipd process
crash occurs with a signature containing the following:
The SBC can leak File Descriptors in cases where there are
certain process errors. For example:
This does not trigger proper closure of sockets. This is avoided by closing the socket that was opened and then setting an error identifying exact error code. |
2 | S-Cz8.1.0m1p18 | S-Cz8.1.0m1p18b | |
29403076 |
The "thread-event" and "thread-usage" HDR categories are displaying incorrectly due to MBCD and SIPD thread names not properly writing into the files and OID output. MBCD and SIPD now properly assign and pass the proper names. |
3 | S-Cz8.1.0m1p9 | S-Cz8.1.0m1p18b | |
29633588 |
During certain configuration activities, the SBC restarts due to an issue caused by improper configuration steps being processed in the sip-manipulation, header-rules. The SBC now returns an error message stating "Invalid Selection" instead of failing. |
3 | S-Cz8.1.0m1p11 | S-Cz8.1.0m1p18b | |
29937232 |
GW unreachable and NetBufCtrl MBUFF errors - This can result in system instability including crash, gw-unreachable and redundancy issues. System will switchover if in HA. Show Buffers output will normally show an increase of errors reported in the NetBufCtrl field due to mbuf’s not being freed. |
2 | SCZ830 | S-Cz830p6 | |
28820258 | On VNF
platforms, when running TLS Chat on VMware-PV 4core (SSFD) + 16GB, TLS Chat
sessions are gradually decreasing. When looking in Wireshark at EXFO, EXFO
forwards a wrong TLS MSRP Chat payload to EXFO UAS.
TCP Chat does not have this error. |
3 | SCZ800 | S-CZ830m1p2 | |
For Advanced Media Termination deployments using the 4600, 6300, 6350 platforms, the SBC is generating RTP and RTCP on the ports 20000 and 20001, instead of generating both on the same port 20000. | 3 | SCZ830 | S-CZ830m1p2 | ||
29522609 | Some calls that are configured to generate ring back tones result in one-way audio. | 2 | SCZ830 | S-CZ830m1p2 | |
29558827 | IMS-AKA calls running over IPv6 networks which utilize VLANs on systems with Mellanox network interfaces may experience one-way audio. | 3 | SCZ830p3 | S-CZ830m1p2 | |
29580506 | SBCs running on virtual platforms or the Acme Packet 3900 could failover when running IMS-AKA calls involving refresh registrations. | 2 | SCZ830p3 | S-CZ830m1p2 | |
29607573 | The SBC is unable to successfully initiate a TCP connection to configured Diameter Accounting (Rf) servers. | 2 | SCZ830 | S-CZ830m1p2 | |
30114764 |
When presenting the content type for SPIROU during SIP to SIPI interworking, the SBC is displaying the text base=spirou. Based on relevant standards, it should display base=itu-92+ as the content type. | 4 | S-CZ830m1 | S-CZ830m1p2 | |
30127762 |
When performing SIP to SIPI interworking, the SBC is not including an ISUP REL in the interworked body of its 400 Missing CSeq message when it rejects applicable calls from the SIPI side. | 4 | S-CZ830m1 | S-CZ830m1p2 | |
30240798 |
The OCSBC closes connections when using some SFTP clients, including WinSCP and MOBA, to upload files over 200KB. Workaround - Use the Linux or Filezilla SFTP client when uploading files greater than 200k. |
3 | S-CZ830p6 | S-CZ830m1p2 | |
30289027 |
Azure does not
always properly reset media interfaces after the OCSBC reboots. Instead, Azure
sometimes tries to process a non-existent packet as soon as the OCSBC comes
back up, resulting in a kernel panic.
Workaround - If you experience a kernel panic after OCSBC reboot, stop and restart the vSBC from the Azure UI. |
3 | SCZ830 | S-CZ830m1p2 | |
30453532 |
The WebGUI available in the S-Cz8.3.0M1 release cannot adequately be used to configure the Enterprise SBC. Workaround: For WebGUI support, use releases either prior to S-Cz8.3.0M1, or releases S-Cz8.3.M1p2 and later. |
2 | SCZ830m1 | SCZ830m1p2 | |
26258705 |
The show sipd srvcc command does not display the correct number of unsuccessful aSRVCC calls. | 3 | SCZ800 | SCZ830 | |
28617938 |
The
anonymize-invite
option for CommMonitor is not RTC. To see a change, you must either reboot or
toggle the admin state. The following is a general admin state toggle
procedure:
|
4 | CZ810m1 | SCZ830 | |
29556215 | The SBC does not send SIPREC data to a remote call server. | 2 | SCZ830 | SCZ830p5 | |
29608499 | In all documents except for the Release Notes and Installation guide, the printed version of this release (S-Cz8.3.0) is incorrectly displayed as S-Cz8.2.0. | 4 | SCZ830 | SCZ830p3 | |
28539155 | When operating as a VNF and using Mellanox interface cards, the OCSBC does not support ICMP over IPv6. | 3 | SCZ820 | SCZ830 | |
29322490 | The SBC intermittently does not process the registration (Event: reg) of a SUBSCRIBE with Expires header=0 that should be created after receiving a NOTIFY with a termination request from a UE. | 2 | SCZ820 | SCZ830 | |
28526228 | Maximum SRTP capacity on VNF platforms is 25% lower than in the SCZ8.1.0 release. Expected capacity will be restored in a follow up patch. | 3 | SCZ820 | SCZ830 | |
28679339 |
When supporting SRVCC roaming calls, the OCSBC is handling SRVCC end-station de-registration events by properly including associated URIs in the 200 OK. It is not, however, saving those associated URIs in its registration cache. This causes the OCSBC to respond to calls to those URIs with 404 not found messages until the end-station re-registers. | 2 | SCZ800 | SCZ830 | |
26313330 |
In some early media call flows, the OCSBC may not present the correct address for RTP causing the call to terminate. | 3 | SCZ800 | SCZ820 | |
26281599 |
The system
feature provided by the
phy-interfaces
overload-protection
parameter and
overload-alarm-threshold
sub-element is not functional. Specifically, enabling the protection and
setting the thresholds does not result in trap and trap-clear events based on
the interface's traffic load.
The applicable ap-smgmt.mib SNMP objects include:
|
3 | SCZ720 | SCZ820 | |
25144010 |
When an OCSBC operating on an Acme Packet 6300 fails over, the secondary can successfully add new ACL entries, but it also retains old ACL entries that it should have deleted. | 3 | SCZ740p1 |
SCZ820 |
|
26183767 |
When operating in HA mode and handling large traffic loads, the active OCSBC stops responding when you restore large configurations that are different from the configuration the active is currently running. The system subsequently goes out of service. | 3 | SCZ800 |
SCZ820 |
|
21975038 | The Acme Packet 4600, 6100, 6300, and 6350 platforms do not support MSRP File Transfer. | 3 | SCZ810 | SCZ820 | |
27579686 | This release does not support TSM. | 2 | SCZ810 | SCZ820 | |
27539750 |
When trying to establish a connection between the SBC and your network, while using TLS version 1.2, the SBC may reject the connection. Workaround: You may need to adjust your cipher list. |
3 | SCZ810 | SCZ810 | |
28062411 | Calls that require SIP/PRACK interworking as invoked by the 100rel-interworking option on a SIP interface do not work in pooled transcoding architectures. | 2 | SCZ740 | SCZ820 | |
28071326 | Calls that require LMSD interworking, as invoked by the lmsd-interworking option on a SIP interface, do not work in pooled transcoding architectures. During call establishment, when sending the 200 OK back to the original caller, the cached SDP is not included. | 2 | SCZ740 | SCZ820 | |
None | The CZ8.1.0
release does not support IPSec on the Acme Packet 3900 and VNF. You must
upgrade to CZ8.1.0p1 to get this support. After you upgrade to CZ8.1.0p1, do
the following:
|
N/A | CZ810 | CZ820 | |
28305575 | On VNFs, the system erroneously displays the IPSEC entitlement under "Keyed (Licensed) Entitlements." The error does not affect any functionality and you do not need to do anything. | 4 | CZ810 | CZ820 | |
28659469 |
When booting
CZ8.1.0M1 on any virtual platform, not all system processes start. This known
issue only occurs on initial boot, and not in an upgrade scenario.
Workaround: Reboot the OCSBC a second time, after it initially starts. |
3 | CZ810m1 | SCZ820 | |
If you configured the ims_aka option, you must also configure sip-interfaces with an ims-aka-profile entry. | 3 | ECZ7.4.0 | ECZ7.4.0m1 | ||
28998693 | For TSM use cases, AP6100 and AP6300 systems do not support data-flow modes. | 2 | SCZ820 | SCZ830 | |
27811129 |
When upgrading an OCSBC from a version that uses License Keys to enable CODECs, you must reboot the system after setting any CODEC entitlements to override the License Keys. | 3 | SCZ810 | SCZ830 | |
30152019 |
Oracle has identified a Potential tSipd crash when configured for a VOLTE w/SRVCC scenario. When the issue is encountered, there is a sipd crash and, if configured, an HA failover. This is a race condition that is relatively rare, but has been seen in internal testing. System Impact of HA Failover:
|
3 | SCZ830p7 | SCZ830m1 | |
28610095 |
In some circumstances, and with add-sdp-invite and add-sdp-profile configured, the OCSBC does not include the original SDP in a Re-INVITE that has no SDP. This does not comply with RFC 3264. Instead, the OCSBC inserts the negotiated media information from the last successful negotiation as the ReINVITE's SDP offer and sends this ReINVITE with inserted SDP to the next hop signaling entity. This issue is evident by the contents of the SDP o line. | 3 | SCZ740 | SCZ830m1 | |
29541242 | Installation and Platform Preparation guide incorrectly includes information about setting up HA on Oracle Cloud platforms. These platforms do not support HA deployments at this time. | 3 | SCZ830 | SCZ830m1 |
ID | Description | Found In | Fixed In |
---|---|---|---|
22322673 |
When running in an HA configuration, the
secondary
OCSBC might go out of
service (OoS) during upgrades, switchovers, and other HA processes while
transitioning from the "Becoming Standby" state. Oracle observes such behavior
in approximately 25% of these circumstances. You can verify the issue with
log.berpd, which can indicate that the media did not synchronize.
Workaround: Reboot the secondary until it successfully reaches the "Standby" state. |
N/A | N/A |
N/A | The T.140-Baudot Relay is not excluded from supported features with pooled transcoding. | N/A | N/A |
21805139 |
RADIUS stop records for IWF calls may display inaccurate values. | N/A | N/A |