30365359 The OECB is sending option ping messages at the wrong intervals. PCZ3.2.0 PCZ3.2.0 p6

30563508

When attempting to run "Set Initial Configuration" from the GUI, the system may hang for as long as 5 minutes while displaying the message box shown below.

This image is described above.Work-around: If the OECB does not reboot in 5 minutes, refresh the browser, log back into the GUI, and run Set Initial Configuration again.

PCZ3.2.0 PCZ3.2.0p8

The GUI does not allow you to edit a user database entry that contains an Address of Record.

Work-around: Delete the entry and add it as a new entry with the changes that you want.

PCZ3.1.0 PCZ3.1.0p2 and PCZ3.2.0
No ID number

If you see mapping errors after upgrading, for example errors about redundancy or media traffic, you may need to swap interface addresses.

Work-around: Compare the MAC addresses on your Virtual Machine (VM) to those on your hardware. If the addresses are different, you need to swap interface addresses. Set the addresses on the hardware to match those from your VM. Use the swap command from the ECB command line.
  1. Use SSH to access the command line prompt on the ECB.
  2. From the ECB prompt type sho interface mapping, and press ENTER.

    The system displays its mappings.

  3. Compare the mappings to your VM mappings.
  4. Type interface-mapping, and press ENTER.
  5. Type swap <eth-if-name_1 eth-if-name_2>, and press ENTER.

    Example: swap wancom0 s1p0

    The system displays the interface mapping information after the swap and a warning that the change can affect services and requires a reboot.

  6. At the Continue prompt, type yes, and press ENTER.
  7. Exit the configuration.
  8. Reboot the ECB.
PCZ3.0.0 PCZ3.1.0