5.26 ent-ee-flt

Use this command to enter Eagle Eyes Filter data in the Eagle Eyes Filter (EE FLT) table. The EE FLT entry consists of a Filter ID and Filter specific data. After the FLT ID is provisioned, it can be used in the dlt-ee-flt and chg-ee-card commands.

Parameters

type (mandatory)
Eagle Eyes Filter Type.
Range:
inc
exl
appl (mandatory)
Card Application Type
Range:
atm
ip
e1t1
ipprot (optional)
Filter based on IP sub-protocol
Range:
sctp
tcp
udp
ipsrc (optional)
Filter based on IP source address
Range:
4 numbers separated by dots, with each number in the range of 0-255
ipdst (optional)
Filter based on IP destination address
Range:
4 numbers separated by dots, with each number in the range of 0-255
ssport (optional)
Filter based on SCTP source port
Range:
0-65535
sdport (optional)
Filter based on SCTP destination port.
Range:
0-65535
stype (optional)
Filter based on SCTP chunk type
Range:
abrt
data
err
hbak
htbt
inak
init
sack
sctppld (optional)
Filter based on SCTP data payload identifier.
Range:
diam
m2pa
m3ua
sua
unspec
sctpstr (optional)
Filter based on SCTP data stream identifier
Range:
0-65535
sscopsu (optional)
Filter based on SSCOP sub-protocol or SU type.
Range:
all
ctrl
data
mtp3si (optional)
Filter MTP3 user.
Range:
bicc
isup
sccp
snm
tup
port (optional)
Filter based on port.
Range:
a-b
a1-a31
b1-b31
all
sutype (optional)
Filter based on SU type.
Range:
allsu
lsu
msu

Example

ent-ee-flt:appl=ip:type=inc:ipprot=sctp:ssport=2048:stype=data:sctpstr=100

ent-ee-flt:appl=atm:type=exl:port=a:sscopsu=data:mtp3si=sccp

ent-ee-flt:appl=e1t1:type=exl:port=a1:sutype=msu:mtp3si=tup

Dependencies

If the appl=ip then ipprot, ipsrc or ipdst parameters must be specified.

If the ssport, sdport or stype parameters are specified, then the ipprot=sctp parameter must be specified.

At least one optional parameter (ipprot or port) must be specified.

If the sctppld parameter is specified, then the stype=data and ipprot=sctp parameters must be specified.

If the sctpstr parameter is specified, then the stype=data and ipprot=sctp parameters must be specified.

The Eagle Eyes Filter table cannot contain more than 200 entries.

The Eagle Eyes Filter table must be available.

If the appl=ip parameter is specified, then the appl=atm and appl=e1t1 parameters must not be specified.

If the appl=atm parameter is specified, then the appl=ip and appl=e1t1 parameters must not be specified.

If the appl=e1t1 parameter is specified, then the appl=atm and appl=ip parameters must not be specified.

If the appl=atm parameter is specified, then the port parameter can only be either a, b or a1.

Notes

IP7 parameters:
  • ipprot, ipsrc, ipdst, ssport, sdport, style, sctppld, sctpstr
ATM parameters:
  • sscopsu, mtp3si, port
E1T1 parameters:
  • sutype, mtp3si, port

Output

ent-ee-flt:appl=atm:type=inc:port=a:sscopsu=data

    tekelecstp 10-03-08 14:43:31 EST  EAGLE 46.0.0
    EE FLT table is (1 of 200) 1% full
    ENT-EE-FLT: MASP A - COMPLTD 
;