5.34 set-mem
Use this command to set values in memory in the communication and application processors. If a card is reloaded, these memory changes are lost.
Parameters
- loc (optional)
- Location. The card location as stenciled on the shelf of the system.
- Range:
- 1101 - 1108, 1111 - 1112, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118, 1109, 1110, 1209, 1210, 1309, 1310, 2109, 2110, 2209, 2210, 2309, 2310, 3109, 3110, 3209, 3210, 3309, 3310, 4109, 4110, 4209, 4210, 4309, 4310, 5109, 5110, 5209, 5210, 5309, 5310, 6109, 6110, 1113, 1115
- op (optional)
- Operation. The operation performed in order to arrive at the final value in the memory location.
Example
set-mem:loc=1109:paddr=h’201000:byte=0:fill=1024
set-mem:card=hipr2-all:paddr=h’202000:word=h’2a:op=and:mask=h’fff
Dependencies
The loc, imt, or card parameter must be specified.
2214 E2214 Cmd Rej: Missing parameter - CARD, LOC, or IMT
Only one of the loc, imt, and card parameters can be specified in the command.
2217 E2217 Cmd Rej: More than one of CARD, LOC, and IMT specified
The card location specified by the loc parameter must be in the database.
2101 E2101 Cmd Rej: Card location is unequipped
All of the subsystem values can be specified with the OAMHC GPLID. The other GPLID values can be specified only with the all subsystem value.
2208 E2208 Cmd Rej: ALL only qualifier allowed with given card type
Values of 1114, 1116, 1117, and 1118 cannot be specified for the loc parameter.
2212 E2212 Cmd Rej: Invalid card type for this command
The byte, word, or dword parameter must be specified.
2210 E2210 Cmd Rej: Byte, WORD or DWORD must be entered
Only one of the byte, word, and dword parameters can be specified in the command.
2218 E2218 Cmd Rej: Only one of BYTE, WORD or DWORD may be entered
The paddr parameter cannot be specified for an SS7 LIM card.
N/A N/A
Memory Type of FWORD is NOT supported at this time.
2693 E2693 Cmd Rej: FWORD is not supported at this time
The addr and paddr parameters cannot be specified together in the command.
2694 E2694 Cmd Rej: Invalid combination of ADDR and PADDR specified
The value specified for the fill parameter cannot exceed 65535.
2017 E2017 Cmd Rej: <parm_desc> is out of range, <min>..<max> - <parm>
Notes
The imt parameter allows this command to be entered for a card that has not been configured in the system.
Output
set-mem:loc=6205:paddr=h'0345fe:byte=2
rlghncxa03w 12-05-22 21:14:03 EST Rel 45.0.0
SDS Response Code 22 from IMT Address H'00fd - command complete.
;