DIA-28441
Oracle Recovery Mangager (Oracle RMAN) clone instance cannot open auto-login wallet.
Cause
The Oracle RMAN clone instance failed to open the auto-login wallet, because either the auto-login wallet was incorrectly configured or did not exist. The Oracle RMAN clone instance can only access an auto-login wallet and not the password wallet, so auto-login wallet must be configured correctly. Operations that require opening the auto-login wallet include point-in-time recovery of an encrypted tablespace and point-in-time recovery of a pluggable database including an encrypted tablespace using Oracle RMAN.
Action
Check and correct the auto-login wallet configuration or create an auto-login wallet from the password wallet, and then retry the operation.
DIA-28441
RMAN clone instance cannot open wallet
Cause
The RMAN clone instance failed to open the auto login wallet in an operation such as a pluggable database (PDB) or tablespace point-in-time recovery because the auto login wallet was incorrectly configured, or did not exist.
Action
Check and correct the auto-login wallet configuration or create an auto-login wallet from the password wallet, and retry the operation.
DIA-28441
RMAN clone instance cannot open wallet
Cause
The RMAN clone instance failed to open the auto login wallet in an operation such as a pluggable database (PDB) or tablespace point-in-time recovery because the auto login wallet was incorrectly configured, or did not exist.
Action
Check and correct the auto-login wallet configuration or create an auto-login wallet from the password wallet, and retry the operation.