Administrative Ethernet Port Cabling Tables RA23
Figure 17-2 shows the cable connections from the servers to the gigabit Ethernet switch in an Oracle Zero Data Loss Recovery Appliance RA23 full rack. The port numbers are the same in racks with fewer storage servers.
The Management Network Switch is located in rack unit 21 on Recovery Appliance RA23. Ethernet cables are blue.
In the following tables, Un denotes the unit height in the rack, where n is the number, such as U20. The cables used for the Management Network Switch are blue in color. Cabling connections marked with * are required for all rack configurations, and represent the minimum rack configuration.
Table 16-2 Ethernet Cabling for the Recovery Appliance RA23 Racks
From Rack Unit(1) | Network Management | To U21 Ethernet Port | Component |
---|---|---|---|
U39 |
NET 0 |
1 |
Storage server |
U39 |
NET MGT |
2 |
Storage server |
U37 |
NET 0 |
3 |
Storage server |
U37 |
NET MGT |
4 |
Storage server |
U35 |
NET 0 |
5 |
Storage server |
U35 |
NET MGT |
6 |
Storage server |
U33 |
NET 0 |
7 |
Storage server |
U33 |
NET MGT |
8 |
Storage server |
U31 |
NET 0 |
9 |
Storage server |
U31 |
NET MGT |
10 |
Storage server |
U29 |
NET 0 |
11 |
Storage server |
U29 |
NET MGT |
12 |
Storage server |
U27 |
NET 0 |
13 |
Storage server |
U27 |
NET MGT |
14 |
Storage server |
U41 |
NET 0 |
15 |
Storage server |
U41 |
NET MGT |
16 |
Storage server |
U25 |
NET 0 |
17 |
Storage server |
U25 |
NET MGT |
18 |
Storage server |
PDU A* |
NET MGT |
19 |
|
PDU B* |
NET MGT |
20 |
|
U23 |
NET 0 |
21 |
Storage server |
U23 |
NET MGT |
22 |
Storage server |
U18 |
NET 0 |
25 |
Storage server |
U18 |
NET MGT |
26 |
Storage server |
U16* |
NET 0 |
29 |
Compute server |
U16* |
NET MGT |
30 |
Compute server |
U14* |
NET 0 |
31 |
Compute server |
U14* |
NET MGT |
32 |
Compute server |
U12 |
NET 0 |
33 |
Storage server |
U12 |
NET MGT |
34 |
Storage server |
U10 |
NET 0 |
35 |
Storage server |
U10 |
NET MGT |
36 |
Storage server |
U08 |
NET 0 |
37 |
Storage server |
U08 |
NET MGT |
38 |
Storage server |
U06* |
NET 0 |
39 |
Storage server |
U06* |
NET MGT |
40 |
Storage server |
U04* |
NET 0 |
41 |
Storage server |
U04* |
NET MGT |
42 |
Storage server |
U02* |
NET 0 |
43 |
Storage server |
U02* |
NET MGT |
44 |
Storage server |
U22* |
NET MGT 0 |
45 |
RDMA Network Fabric switch |
U20* |
NET MGT 0 |
46 |
RDMA Network Fabric switch |
U01* |
NET MGT 0 |
47 |
|
External |
48 |
Footnote 1 Un is the unit location in the rack, where n is the number.
* These marked components are required for all rack configurations, and together represent the minimum rack configuration.