System Motherboard Components

The following table lists the system motherboard components.

Table E-8 System Motherboard Components

Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)

/SYS/MB

FRU

General host system motherboard FRU

 

/SYS/MB/NET[0 ]

FRU

Host Ethernet FRU

 

/SYS/MB/PCIE[1-9]

FRU

PCIe slot

 

/SYS/MB/PCIE[1-9]/PRSNT

Discrete Sensor

PCIe slot is occupied.

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/PCIE[1-9]/P_ENABLE_STATE

Indicator

PCIe slot power indicator

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/RISER[2-6]

FRU

PCIe Riser card FRU at Slot 2 and Slot 6 (Database Full Height card configuration)

 

/SYS/MB/RISER[2-6]/PRSNT

Discrete Sensor

PCIe Riser Card at Slot 2 or Slot 6 is present

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/RISER2/PCIE[2, 4]

FRU

PCIE Slot on RISER2

Slot 2 - x16 CEM slot

Slot 4 - x1 CEM slot for SMART NIC

 

/SYS//SYS/MB/RISER2/PCIE[2, 4]/PRSNT

Discrete Sensor

Option card inserted into PCIe Slots on Riser 2

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS//SYS/MB/RISER2/PCIE[2, 4]/P_ENABLE_STATE

State Sensor

PCIe slots on Riser 2 Power Enable State

02h-SLOT POWER ENABLED

01h-SLOT POWER DISABLED

/SYS//SYS/MB/RISER6/PCIE[6, 8]/PRSNT

Discrete Sensor

Option card inserted into PCIe Slots on Riser 6

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS//SYS/MB/RISER6/PCIE[6, 8]/P_ENABLE_STATE

State Sensor

PCIe slots on Riser 6 Power Enable State

02h-SLOT POWER ENABLED

01h-SLOT POWER DISABLED

/SYS/MB/ROT

FRU

Root of Trust FRU

Optional card is present in slot 1 (only supported slot)

 

/SYS//SYS/MB/ROT/PRSNT

Discrete Sensor

Root of Trust is Present

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/MB/T_IN_ZONE[0-3]

Threshold sensor

Cooling zone input temperature sensor

Degrees Celsius

/SYS/MB/T_OUT_ZONE[0-3]

Threshold sensor

Cooling zone output temperature sensor

Degrees Celsius

/SYS/SP

FRU

Service processor FRU

 

/SYS/SP/OK

Indicator

 

SP OK LED

Color: Green

Location: Front panel

On: SP is operating.

Off: SP requires service.

/SYS/SP/NET[0-1]

FRU

SP Ethernet FRU