Power Unit Components
The following table lists the power unit components.
Table E-2 Power Unit Components
Component Name (Oracle ILOM CLI Targets) | IPMI Type | Description | Values (if applicable) |
---|---|---|---|
/SYS/PDB |
FRU |
Power distribution board FRU |
|
/SYS/PS[0-1] |
FRU |
Power supply FRU |
|
/SYS/PS[0-1]/PRSNT |
Discrete sensor |
Power supply is present. (Hidden) |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |
/SYS/PS[0-1]/STATE |
State sensor |
Power supply state sensor Multistate, power supply sensor type, per IPMI |
Presence detected Failure detected Predictive failure Power supply input lost Power supply input lost or out-of-range Power supply input out-of-range Configuration error |
/SYS/PS[0-1]/P_IN |
Threshold sensor |
Input power draw |
Watts |
/SYS/PS[0-1]/P_OUT |
Threshold sensor |
Output power |
Watts |
/SYS/PS[0-1]/V_IN |
Threshold sensor |
Power supply input voltage |
Volts |
/SYS/PS[0-1]/V_12V |
Threshold sensor |
Power supply 12V output voltage |
Volts |
/SYS/PS[0-1]/V_12V_STBY |
Threshold sensor |
Power supply 12V standby output voltage |
Volts |
/SYS/PS[0-1]/T_IN |
Threshold sensor |
PSU input temperature |
Degrees Celsius |
/SYS/PS[0-1]/T_OUT |
Threshold sensor |
PSU output temperature |
Degrees Celsius |