Disk Backplane Components

The following table lists the disk backplane (DBP) components.

Table E-4 Disk Backplane Components

Component Name (Oracle ILOM CLI Targets) IPMI Type Description Values (if applicable)

/SYS/DBP

FRU

Disk backplane FRU

 

/SYS/DBP/PRSNT

Discrete sensor

Disk backplane presence (Hidden)

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/DBP/HDD[0- x ]

FRU

Hard disk drives (HDD)

 

/SYS/DBP/HDD[0- x ]/PRSNT

Discrete sensor

Hard disk drive presence(Hidden)

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/DBP/HDD[0- x ]/STATE

State sensor

Hard disk drive state

01h-FAULT_STATUS

02h-IDENTITY

04h-INSTALLED

20h-SLOT_POWER_OFF

/SYS/DBP/HDD[0- x ]/SERVICE

Indicator

Fault-Service Required LED

Color: Amber

Location: HDD

Off: Normal

On: HDD was diagnosed as failed

/SYS/DBP/HDD[0- x ]/OK2RM

Indicator

Hard disk drive OK to remove

Color: Blue

Location: HDD

Off: Normal

On: HDD is OK to remove

/SYS/DBP/HDD[0- x ]/NVME

FRU

NVMe drive FRU

 

/SYS/DBP/HDD[0- x ]/NVME/PRSNT

Discrete sensor

NVMe device presence

01h-ENTITY_ABSENT

02h-ENTITY_PRESENT

/SYS/VREG_DBP_ERR

Discrete sensor

Disk backplane voltage regulator-down (VRD) error (Hidden)

01h-DEASSERTED

02h-ASSERTED

/SYS/VREG_USB_ERR

Discrete sensor

Universal Serial Bus (USB) VRD error (Hidden)

01h-DEASSERTED

02h-ASSERTED