Drive Components
The following table lists the hard disk drive (HDD) and solid state drive (SSD) components.
Table E-5 Drive Components
Component Name (Oracle ILOM CLI Targets) | IPMI Type | Description | Values (if applicable) |
---|---|---|---|
/SYS/DBP/HDD[0- x ] |
FRU |
Hard disk drive FRU |
From host |
/SYS/DBP/HDD[0- x ]/PRSNT |
Discrete sensor |
Hard disk drive presence |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |
/SYS/DBP/HDD[0- x ]/STATE |
Discrete sensor |
Writable multistate, slot/connector sensor type, per IPMI |
01h-FAULT_STATUS 02h-IDENTITY 04h-INSTALLED 20h-SLOT_POWER_OFF |
/SYS/DBP/HDD[0- x ]/SERVICE |
Indicator |
Hard disk drive Fault-Service Required LED |
Color: Amber Location: HDD Off: Normal On: Hard disk drive was diagnosed as faulty. |
/SYS/DBP/HDD[0- x ]/OK2RM |
Indicator |
Hard disk drive OK to Remove LED |
Color: Blue Location: HDD Off: Normal On: Drive is ready to remove. |
/SYS/DBP/HDD[0- 3 ]/NVME |
FRU |
NVMe drive FRU |
|
/SYS/DBP/HDD[0- 3 ]/NVME/PRSNT |
Discrete sensor |
NVMe device presence |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |
/SYS/MB/SSDR[0-1] |
FRU |
Internal M.2 SSD riser (2) FRU |
|
/SYS/MB/SSDR[0-1]/PRSNT |
Discrete sensor |
Solid-state drive (SSD) riser presence (2 risers) |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |
/SYS/MB/SSDR[0-1]/SSD[0-1] |
FRU |
Internal SSD drive FRU |
|
/SYS/MB/SSDR[0-1]/SSD[0-1]/PRSNT |
Discrete sensor |
SSD drive presence (1 SSD per riser on 2U) (Hidden) |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |
/SYS/MB/SSDR[0-1]/SSD[0-1]/STATE |
State sensor |
SSD drive state |
04h-INSTALLED 20h-SLOT POWER OFF |
/SYS/MB/SSDR[0-1]/SSD[0-1]/NVME |
FRU |
Internal SSD that is NVM Express FRU |
|
/SYS/MB/SSDR[0-1]/SSD[0-1]/NVME/PRSNT |
Discrete sensor |
Indicates the SSD is PCIe (NVMExpress) |
01h-ENTITY_ABSENT 02h-ENTITY_PRESENT |