22.3 Administration Network Cabling
This topic shows the administration network cabling for Oracle Exadata Storage Expansion Rack X11M and X10M.
The port on the storage servers is labeled NET0, and connects to the Management Network Switch located in rack unit 21 on Oracle Exadata Storage Expansion Racks.
The following table shows the cable connections from the rack components to the Management Network Switch in Oracle Exadata Storage Expansion Rack X11M and X10M
Table 22-2 Administration Network Cabling for Oracle Exadata Storage Expansion Rack X11M and X10M
From Rack Unit | Type of Equipment | Management Network Switch Port |
---|---|---|
U41 |
Storage Server |
15 |
U39 |
Storage Server |
1 |
U37 |
Storage Server |
3 |
U35 |
Storage Server |
5 |
U33 |
Storage Server |
7 |
U31 |
Storage Server |
9 |
U29 |
Storage Server |
11 |
U27 |
Storage Server |
13 |
U25 |
Storage Server |
17 |
U23 |
Storage Server |
21 |
U22 |
RDMA Network Fabric leaf switch |
45 |
U20 |
RDMA Network Fabric leaf switch |
46 |
U18 |
Storage Server |
25 |
U16 |
Storage Server |
29 |
U14 |
Storage Server |
31 |
U12 |
Storage Server |
33 |
U10 |
Storage Server |
35 |
U8 |
Storage Server |
37 |
U6 |
Storage Server |
39 |
U4 |
Storage Server |
41 |
U2 |
Storage Server |
43 |
U1 |
RDMA Network Fabric spine switch |
47 |