14.2 Administration Network Ethernet Port Cabling
This topic describes the administration network cabling in Oracle Exadata Database Machine X11M and X10M.
The Management Network Switch is located in rack unit 21 (U21) on Oracle Exadata Database Machine X11M and X10M racks. Each component in the rack connects to the Management Network Switch as described in the following table.
In the following table, UN denotes the rack unit location, where U42 is at the top of the rack and U1 is at the bottom of the rack.
Table 14-1 Administration Network Cabling for Oracle Exadata Database Machine X11M or X10M
From Rack Unit | Equipment Type | Network Port | To Management Network Switch Port |
---|---|---|---|
U41 |
Storage Server |
NET 0 |
15 |
U41 |
Storage Server |
NET MGT (ILOM) |
16 |
U39 |
Storage Server or Database Server |
NET 0 |
1 |
U39 |
Storage Server or Database Server |
NET MGT (ILOM) |
2 |
U37 |
Storage Server or Database Server |
NET 0 |
3 |
U37 |
Storage Server or Database Server |
NET MGT (ILOM) |
4 |
U35 |
Storage Server or Database Server |
NET 0 |
5 |
U35 |
Storage Server or Database Server |
NET MGT (ILOM) |
6 |
U33 |
Storage Server or Database Server |
NET 0 |
7 |
U33 |
Storage Server or Database Server |
NET MGT (ILOM) |
8 |
U31 |
Storage Server or Database Server |
NET 0 |
9 |
U31 |
Storage Server or Database Server |
NET MGT (ILOM) |
10 |
U29 |
Storage Server or Database Server |
NET 0 |
11 |
U29 |
Storage Server or Database Server |
NET MGT (ILOM) |
12 |
U27 |
Storage Server or Database Server |
NET 0 |
13 |
U27 |
Storage Server or Database Server |
NET MGT (ILOM) |
14 |
U25 |
Storage Server or Database Server |
NET 0 |
17 |
U25 |
Storage Server or Database Server |
NET MGT (ILOM) |
18 |
U23 |
Storage Server or Database Server |
NET 0 |
21 |
U23 |
Storage Server or Database Server |
NET MGT (ILOM) |
22 |
U22 |
RDMA Network Fabric Leaf Switch |
NET MGT 0 |
45 |
U20 |
RDMA Network Fabric Leaf Switch |
NET MGT 0 |
46 |
U18 |
Storage Server or Database Server |
NET 0 |
25 |
U18 |
Storage Server or Database Server |
NET MGT (ILOM) |
26 |
U16 |
Storage Server or Database Server |
NET 0 |
29 |
U16 |
Storage Server or Database Server |
NET MGT (ILOM) |
30 |
U14 |
Storage Server or Database Server |
NET 0 |
31 |
U14 |
Storage Server or Database Server |
NET MGT (ILOM) |
32 |
U12 |
Storage Server or Database Server |
NET 0 |
33 |
U12 |
Storage Server or Database Server |
NET MGT (ILOM) |
34 |
U10 |
Storage Server or Database Server |
NET 0 |
35 |
U10 |
Storage Server or Database Server |
NET MGT (ILOM) |
36 |
U8 |
Storage Server or Database Server |
NET 0 |
37 |
U8 |
Storage Server or Database Server |
NET MGT (ILOM) |
38 |
U6 |
Storage Server |
NET 0 |
39 |
U6 |
Storage Server |
NET MGT (ILOM) |
40 |
U4 |
Storage Server |
NET 0 |
41 |
U4 |
Storage Server |
NET MGT (ILOM) |
42 |
U2 |
Storage Server |
NET 0 |
43 |
U2 |
Storage Server |
NET MGT (ILOM) |
44 |
U1 |
RDMA Network Spine Switch |
NET MGT 0 |
47 |
PDU-A |
Power Distribution Unit (PDU) |
NET MGT |
19 |
PDU-B |
Power Distribution Unit (PDU) |
NET MGT |
23 |