2.3.2.2 Cabling Two RoCE Network Fabric Racks Together with Down Time Allowed
Use this simpler procedure to cable together two racks with RoCE Network Fabric where some down-time can be tolerated.
This procedure is for systems with RoCE Network Fabric (X8M or later) using Oracle Exadata System Software Release 20.1.0 or later.
In this procedure, the existing rack is R1, and the new rack is R2.
Use the applicable cabling tables depending on your system configuration:
- Procure and prepare the RoCE Network Fabric cables that you will use to interconnect the racks.
Ensure you have all the RDMA Network Fabric cables required to interconnect the racks.
Label both ends of every cable.
Do not disconnect any existing cables or connect any new cables until instructed later in the procedure.
For the required cross-rack cabling information, refer to the applicable cabling tables for your system configuration. See also:
Note that all specified cable lengths assume the racks are physically adjacent. If this is not the case, you may need longer cables.
- Ensure the new rack is near the existing rack.
Ensure that the RDMA Network Fabric cables can reach the switches in each rack.
- Ensure you have a backup of the current switch configuration for each switch in the existing and new rack.
See Backing Up Settings on the RoCE Network Fabric Switch in Oracle Exadata Database Machine Maintenance Guide.
- Shut down all servers on both the new rack (R2) and the existing rack (R1).The switches should remain available.
- Update the firmware to the latest available release on all of the RoCE Network Fabric switches.
For this step, treat all of the switches as if they belong to a single rack system.
See Updating RoCE Network Fabric Switch Firmware in Oracle Exadata Database Machine Maintenance Guide.
- Apply the multi-rack golden configuration settings on the RoCE Network Fabric switches.
Use the procedure described in Applying Golden Configuration Settings on RoCE Network Fabric Switches, in Oracle Exadata Database Machine Maintenance Guide.
- Enable the leaf switch server ports.
The leaf switch server ports may be disabled as a consequence of applying the multi-rack golden configuration settings in the previous step.
To ensure that the leaf switch server ports are enabled, log in to each of the four leaf switches and run the following commands on each leaf switch:
rack1sw-rocea0# config term rack1sw-rocea0# int eth1/8-30 rack1sw-rocea0# no shut rack1sw-rocea0# copy running-config startup-config
- Perform the physical cabling of the switches.
- In Rack 2, remove the existing inter-switch connections between the two leaf switches, R2UL and R2LL.
- In Rack 2, cable each leaf switch to the spine switches using the applicable cabling tables.
- In Rack 1, remove the existing inter-switch connections between the two leaf switches, R1UL and R1LL.
- In Rack 1, cable each leaf switch to the spine switches using the applicable cabling tables.
- Confirm each switch is available and connected.
For each of the six switches (two spine switches and four leaf switches), confirm the output from the
show interface status
command showsconnected
and100G
for each connected inter-switch port. Use the appropriate cabling tables to identify the ports that should be connected.In the following examples, the leaf switches are ports Eth1/4 to Eth1/7, and Eth1/30 to Eth1/33. The spine switches are ports Eth1/5 to Eth1/20.
When run from a spine switch, the output should be similar to the following:
rack1sw-roces0# show interface status -------------------------------------------------------------------------------- Port Name Status Vlan Duplex Speed Type -------------------------------------------------------------------------------- mgmt0 -- connected routed full 1000 -- -------------------------------------------------------------------------------- Port Name Status Vlan Duplex Speed Type -------------------------------------------------------------------------------- ... Eth1/5 RouterPort5 connected routed full 100G QSFP-100G-CR4 Eth1/6 RouterPort6 connected routed full 100G QSFP-100G-SR4 Eth1/7 RouterPort7 connected routed full 100G QSFP-100G-CR4 Eth1/8 RouterPort8 connected routed full 100G QSFP-100G-SR4 Eth1/9 RouterPort9 connected routed full 100G QSFP-100G-CR4 Eth1/10 RouterPort10 connected routed full 100G QSFP-100G-SR4 Eth1/11 RouterPort11 connected routed full 100G QSFP-100G-CR4 Eth1/12 RouterPort12 connected routed full 100G QSFP-100G-SR4 Eth1/13 RouterPort13 connected routed full 100G QSFP-100G-CR4 Eth1/14 RouterPort14 connected routed full 100G QSFP-100G-SR4 Eth1/15 RouterPort15 connected routed full 100G QSFP-100G-CR4 Eth1/16 RouterPort16 connected routed full 100G QSFP-100G-SR4 Eth1/17 RouterPort17 connected routed full 100G QSFP-100G-CR4 Eth1/18 RouterPort18 connected routed full 100G QSFP-100G-SR4 Eth1/19 RouterPort19 connected routed full 100G QSFP-100G-CR4 Eth1/20 RouterPort20 connected routed full 100G QSFP-100G-SR4 Eth1/21 RouterPort21 xcvrAbsen routed full 100G -- ...
When run from a leaf switch, the output should be similar to the following:
rack1sw-rocea0# show interface status -------------------------------------------------------------------------------- Port Name Status Vlan Duplex Speed Type -------------------------------------------------------------------------------- mgmt0 -- connected routed full 1000 -- -------------------------------------------------------------------------------- Port Name Status Vlan Duplex Speed Type -------------------------------------------------------------------------------- ... Eth1/4 RouterPort1 connected routed full 100G QSFP-100G-CR4 Eth1/5 RouterPort2 connected routed full 100G QSFP-100G-CR4 Eth1/6 RouterPort3 connected routed full 100G QSFP-100G-CR4 Eth1/7 RouterPort4 connected routed full 100G QSFP-100G-CR4 Eth1/8 celadm14 connected 3888 full 100G QSFP-100G-CR4 ... Eth1/29 celadm01 connected 3888 full 100G QSFP-100G-CR4 Eth1/30 RouterPort5 connected routed full 100G QSFP-100G-SR4 Eth1/31 RouterPort6 connected routed full 100G QSFP-100G-SR4 Eth1/32 RouterPort7 connected routed full 100G QSFP-100G-SR4 Eth1/33 RouterPort8 connected routed full 100G QSFP-100G-SR4 ...
- Check the neighbor discovery for every switch in racks R1 and R2.
Log in to each switch and use the
show lldp neighbors
command. Make sure that all switches are visible and check the switch ports assignment against the applicable cabling tables.A spine switch should see the two leaf switches in each rack, but not the other spine switch. The output for a spine switch should be similar to the following:
Note:
The interfaces output in thePort ID
column are different for each switch based on the applicable cabling tables.rack1sw-roces0# show lldp neighbors ... Device ID Local Intf Hold-time Capability Port ID rack1-adm0 mgmt0 120 BR Ethernet1/47 rack1sw-roceb0 Eth1/5 120 BR Ethernet1/5 rack2sw-roceb0 Eth1/6 120 BR Ethernet1/5 rack1sw-roceb0 Eth1/7 120 BR Ethernet1/7 rack2sw-roceb0 Eth1/8 120 BR Ethernet1/7 rack1sw-roceb0 Eth1/9 120 BR Ethernet1/4 rack2sw-roceb0 Eth1/10 120 BR Ethernet1/4 rack1sw-roceb0 Eth1/11 120 BR Ethernet1/6 rack2sw-roceb0 Eth1/12 120 BR Ethernet1/6 rack1sw-rocea0 Eth1/13 120 BR Ethernet1/5 rack2sw-rocea0 Eth1/14 120 BR Ethernet1/5 rack1sw-rocea0 Eth1/15 120 BR Ethernet1/7 rack2sw-rocea0 Eth1/16 120 BR Ethernet1/7 rack1sw-rocea0 Eth1/17 120 BR Ethernet1/4 rack2sw-rocea0 Eth1/18 120 BR Ethernet1/4 rack1sw-rocea0 Eth1/19 120 BR Ethernet1/6 rack2sw-rocea0 Eth1/20 120 BR Ethernet1/6 Total entries displayed: 17
Each leaf switch should see the two spine switches, but not the other leaf switches. The output for a leaf switch should be similar to the following:
Note:
The interfaces output in thePort ID
column are different for each switch based on the applicable cabling tables.rack1sw-rocea0# show lldp neighbors ... Device ID Local Intf Hold-time Capability Port ID switch mgmt0 120 BR Ethernet1/46 rack1sw-roces0 Eth1/4 120 BR Ethernet1/17 rack1sw-roces0 Eth1/5 120 BR Ethernet1/13 rack1sw-roces0 Eth1/6 120 BR Ethernet1/19 rack1sw-roces0 Eth1/7 120 BR Ethernet1/15 rack2sw-roces0 Eth1/30 120 BR Ethernet1/17 rack2sw-roces0 Eth1/31 120 BR Ethernet1/13 rack2sw-roces0 Eth1/32 120 BR Ethernet1/19 rack2sw-roces0 Eth1/33 120 BR Ethernet1/15 rocetoi-ext-sw Eth1/36 120 BR Ethernet1/49 Total entries displayed: 10
- Power on all servers in racks R1 and R2.
- For each rack, confirm the multi-rack cabling by running the
verify_roce_cables.py
script.Refer to My Oracle Support Doc ID 2587717.1 for download and usage instructions.
Check the output of the
verify_roce_cables.py
script against the applicable cabling tables. Also, check that output in theCABLE OK?
columns contains theOK
status.When running the script, two input files are used, one for nodes and one for switches. Each file should contain the servers or switches on separate lines. Use fully qualified domain names or IP addresses for each server and switch.
The following output is a partial example of the command results:
# ./verify_roce_cables.py -n nodes.rack1 -s switches.rack1 SWITCH PORT (EXPECTED PEER) LEAF-1 (rack1sw-rocea0) : CABLE OK? LEAF-2 (rack1sw-roceb0) : CABLE OK? ----------- -------------- --------------------------- : -------- ----------------------- : --------- Eth1/4 (ISL peer switch) : rack1sw-roces0 Ethernet1/17 : OK rack1sw-roces0 Ethernet1/9 : OK Eth1/5 (ISL peer switch) : rack1sw-roces0 Ethernet1/13 : OK rack1sw-roces0 Ethernet1/5 : OK Eth1/6 (ISL peer switch) : rack1sw-roces0 Ethernet1/19 : OK rack1sw-roces0 Ethernet1/11: OK Eth1/7 (ISL peer switch) : rack1sw-roces0 Ethernet1/15 : OK rack1sw-roces0 Ethernet1/7 : OK Eth1/12 (celadm10) : rack1celadm10 port-1 : OK rack1celadm10 port-2 : OK Eth1/13 (celadm09) : rack1celadm09 port-1 : OK rack1celadm09 port-2 : OK Eth1/14 (celadm08) : rack1celadm08 port-1 : OK rack1celadm08 port-2 : OK ... Eth1/15 (adm08) : rack1dbadm08 port-1 : OK rack1dbadm08 port-2 : OK Eth1/16 (adm07) : rack1dbadm07 port-1 : OK rack1dbadm07 port-2 : OK Eth1/17 (adm06) : rack1dbadm06 port-1 : OK rack1dbadm06 port-2 : OK ... Eth1/30 (ISL peer switch) : rack2sw-roces0 Ethernet1/17 : OK rack2sw-roces0 Ethernet1/9 : OK Eth1/31 (ISL peer switch) : rack2sw-roces0 Ethernet1/13 : OK rack2sw-roces0 Ethernet1/5 : OK Eth1/32 (ISL peer switch) : rack2sw-roces0 Ethernet1/19 : OK rack2sw-roces0 Ethernet1/11: OK Eth1/33 (ISL peer switch) : rack2sw-roces0 Ethernet1/15 : OK rack2sw-roces0 Ethernet1/7 : OK
# ./verify_roce_cables.py -n nodes.rack2 -s switches.rack2 SWITCH PORT (EXPECTED PEER) LEAF-1 (rack2sw-rocea0) : CABLE OK? LEAF-2 (rack2sw-roceb0) : CABLE OK? ----------- -------------- --------------------------- : -------- ----------------------- : --------- Eth1/4 (ISL peer switch) : rack1sw-roces0 Ethernet1/18 : OK rack1sw-roces0 Ethernet1/10: OK ...
- Verify the RoCE Network Fabric operation by using the
infinicheck
command.Use the following recommended command sequence. In each command,
hosts.lst
contains a list of database server RoCE Network Fabric IP addresses (2 RoCE Network Fabric IP addresses for each database server), andcells.lst
contains a list of RoCE Network Fabric IP addresses for the storage servers (2 RoCE Network Fabric IP addresses for each storage server).-
Use
infinicheck
with the-z
option to clear the files that were created during the last run of theinfinicheck
command. For example:# /opt/oracle.SupportTools/ibdiagtools/infinicheck -g hosts.lst -c cells.lst -z
-
Use
infinicheck
with the-s
option to set up user equivalence for password-less SSH across the RoCE Network Fabric. For example:# /opt/oracle.SupportTools/ibdiagtools/infinicheck -g hosts.lst -c cells.lst -s
-
Finally, verify the RoCE Network Fabric operation by using
infinicheck
with the-b
option, which is recommended on newly imaged machines where it is acceptable to suppress thecellip.ora
andcellinit.ora
configuration checks. For example:# /opt/oracle.SupportTools/ibdiagtools/infinicheck -g hosts.lst -c cells.lst -b INFINICHECK [Network Connectivity, Configuration and Performance] #### FABRIC TYPE TESTS #### System type identified: RoCE Verifying User Equivalance of user=root from all DBs to all CELLs. #### RoCE CONFIGURATION TESTS #### Checking for presence of RoCE devices on all DBs and CELLs [SUCCESS].... RoCE devices on all DBs and CELLs look good Checking for RoCE Policy Routing settings on all DBs and CELLs [SUCCESS].... RoCE Policy Routing settings look good Checking for RoCE DSCP ToS mapping on all DBs and CELLs [SUCCESS].... RoCE DSCP ToS settings look good Checking for RoCE PFC settings and DSCP mapping on all DBs and CELLs [SUCCESS].... RoCE PFC and DSCP settings look good Checking for RoCE interface MTU settings. Expected value : 2300 [SUCCESS].... RoCE interface MTU settings look good Verifying switch advertised DSCP on all DBs and CELLs ports ( ) [SUCCESS].... Advertised DSCP settings from RoCE switch looks good #### CONNECTIVITY TESTS #### [COMPUTE NODES -> STORAGE CELLS] (60 seconds approx.) (Will walk through QoS values: 0-6) [SUCCESS]..........Results OK [SUCCESS]....... All can talk to all storage cells [COMPUTE NODES -> COMPUTE NODES] ...
-
- After cabling the racks together, proceed to Configuring the New Hardware to finish the configuration of the new rack.