2.3.3.1 Cabling Several RoCE Network Fabric Racks Together
Use this procedure to add another rack to an existing multi-rack system with RoCE Network Fabric.
This procedure is for systems with RoCE Network Fabric (X8M or later) using Oracle Exadata System Software Release 20.1.0 or later.
WARNING:
Take time to read and understand this procedure before implementation. Pay careful attention to all the instructions, not just the command examples. A system outage may occur if the instructions are not applied correctly.
In this procedure, the existing racks are R1, R2, … ,Rn, and the new rack is Rn+1.
Note:
Cabling three or more racks together requires no downtime for the existing racks R1, R2, …, Rn. Only the new rack, Rn+1, is powered down initially.Use the applicable cabling tables depending on your system:
- Multi-Rack Cabling Tables for Oracle Exadata X9M and Later Models
- Multi-Rack Cabling Tables for Oracle Exadata X8M Models
Remember the following when instructed to perform physical cabling in the RoCE Network Fabric:
-
Cabling within a live network must be done carefully to avoid potentially serious disruptions.
-
When consulting the multi-rack cabling tables, remember that besides any new cabling, you may also need to alter existing links.
-
Use the appropriate cabling tables to check and verify all the inter-switch connections whenever you change the cabling on a switch.
In the following steps, these example switch names are used for the new rack (Rn+1):
rack5sw-roces0
: Rack 5 spine switch (R5SS)rack5sw-rocea0
: Rack 5 lower leaf switch (R5LL)rack5sw-roceb0
: Rack 5 upper leaf switch (R5UL)
- Procure and prepare the RoCE Network Fabric cables that you will use to interconnect the racks.
Ensure you have all the RDMA Network Fabric cables required to interconnect the racks.
Label both ends of every cable.
Do not disconnect any existing cables or connect any new cables until instructed later in the procedure.
For the required cross-rack cabling information, refer to the applicable cabling tables for your system configuration. See also:
Note that all specified cable lengths assume the racks are physically adjacent. If this is not the case, you may need longer cables.
- Ensure the new rack is near the existing racks (R1, R2, …, Rn).
Ensure that the RDMA Network Fabric cables can reach the switches in each rack.
- Ensure you have a backup of the current switch configuration for each switch in the existing racks and the new rack.For each switch, complete the steps in the Oracle Exadata Database Machine Maintenance Guide, section Backing Up Settings on the RoCE Network Fabric Switch.
- Shut down all servers in the new rack (Rn+1).Refer to Powering Off Oracle Exadata Rack. The switches must remain online and available.
- Verify the configuration of the existing RoCE Network Fabric switches.
Before you configure the RoCE Network Fabric switches in the new rack (Rn+1), check the configuration of the RoCE Network Fabric switches in the existing racks (R1, R2, …, Rn). You must do this to ensure that every switch uses a unique loopback octet. The loopback octet is the last octet of the switch loopback IP address.
- Connect to an existing RoCE Network Fabric leaf switches and determine the loopback octet for the
switch.
Use the command shown in the following example.
rack1sw-rocea0# show interface loopback 1 | grep Address Internet Address is 192.128.10.101/32
In the example, the loopback octet is
101
. - Determine the loopback octet for every other leaf switch.
Use the command shown in the following example.
rack1sw-rocea0# show nve peers Interface Peer-IP State LearnType --------- -------------------------------------- ----- --------- nve1 192.128.10.102 Up CP nve1 192.128.10.103 Up CP nve1 192.128.10.104 Up CP nve1 192.128.10.105 Up CP nve1 192.128.10.106 Up CP nve1 192.128.10.107 Up CP nve1 192.128.10.108 Up CP
In the example, the output shows seven other leaf switches having loopback octet values from
102
to108
. This output is consistent with an existing system containing four racks. - Determine the loopback octet for every spine switch.
Use the command shown in the following example.
rack1sw-rocea0# show bgp l2vpn evpn summary | egrep -v "BGP|Idle|I|Neighbor|memory" 192.128.10.201 4 65502 9161 581 75716 0 0 08:53:23 3687 192.128.10.202 4 65502 9160 582 75716 0 0 08:34:20 3687 192.128.10.203 4 65502 9162 582 75716 0 0 08:41:22 3687 192.128.10.204 4 65502 9163 582 75716 0 0 08:50:27 3687
In the example, the output shows four spine switches having loopback octet values from
201
to204
. This output is also consistent with an existing system containing four racks. - Validate the configuration of the existing RoCE Network Fabric switches.
Check the information gathered from the existing RoCE Network Fabric switches to ensure that every switch uses a unique loopback octet value and that all the values are as expected.
Verify that the information gathered from the existing RoCE Network Fabric switches conforms to the following conventions:
-
On the leaf switches, the overall range of loopback octet values should start with
101
and increase incrementally (by 1) for each leaf switch.According to the best-practice convention, the loopback octet value for each leaf switch should be configured as follows:
-
101
- Rack 1 lower leaf switch (R1LL) -
102
- Rack 1 upper leaf switch (R1UL) -
103
- Rack 2 lower leaf switch (R2LL) -
104
- Rack 2 upper leaf switch (R2UL) -
105
- Rack 3 lower leaf switch (R3LL) -
106
- Rack 3 upper leaf switch (R3UL), and so on.
-
-
On the spine switches, the range of loopback octet values should start with
201
and increase incrementally (by 1) for each spine switch.According to the best-practice convention, the loopback octet value for each spine switch should be configured as follows:
-
201
- Rack 1 spine switch (R1SS) -
202
- Rack 2 spine switch (R2SS) -
203
- Rack 3 spine switch (R3SS) -
204
- Rack 4 spine switch (R4SS), and so on.
-
Caution:
If the switches in the existing racks (R1, R2, …, Rn) don't conform to the above conventions, then you must take special care to assign unique loopback octet values to the switches in the new rack (Rn+1) as part of applying their golden configuration settings (in the next step).
If multiple switches use the same loopback octet, the RoCE Network Fabric cannot function correctly, resulting in a system outage.
-
- Connect to an existing RoCE Network Fabric leaf switches and determine the loopback octet for the
switch.
- Apply the golden configuration settings on the RoCE Network Fabric switches in the new rack (Rn+1).
Combine the information about the existing RoCE Network Fabric switches you gathered in the previous step and the procedure described in Applying Golden Configuration Settings on RoCE Network Fabric Switches (in Oracle Exadata Database Machine Maintenance Guide).
Caution:
Take care when performing this step, as misconfiguration of the RoCE Network Fabric will likely cause a system outage.
For example, every switch in a multi-rack configuration must have a unique loopback octet. If multiple switches use the same loopback octet, the RoCE Network Fabric cannot function correctly, resulting in a system outage.
- Enable the leaf switch server ports on the RoCE Network Fabric leaf switches in the new rack (Rn+1).
The leaf switch server ports may be disabled as a consequence of applying the multi-rack golden configuration settings in the previous step.
To ensure that the leaf switch server ports are enabled, log in to each of the leaf switches in the new rack and run the following commands on each switch:
rack5sw-rocea0# config term rack5sw-rocea0# int eth1/8-30 rack5sw-rocea0# no shut rack5sw-rocea0# copy running-config startup-config
- Perform the physical cabling of the switches in the new rack (Rn+1).
Caution:
Cabling within a live network must be done carefully to avoid potentially serious disruptions.
- Remove the eight existing inter-switch connections (ports 4, 5, 6, 7 and 30, 31, 32, 33) between each leaf switch in the new rack (Rn+1).
- Cable the leaf switches in the new rack according to the applicable
cabling table.
For example, if you are adding a 5th rack to a system using Exadata X9M (or later model) racks, then use "Table 4-17 Leaf Switch Connections for the Fifth Rack in a Five-Rack System".
- Add the new rack to the switches in the existing racks (R1 to Rn).
- For an existing rack (Rx), cable the lower leaf switch RxLL according to the applicable cabling table.
- For the same rack, cable the upper leaf switch RxUL according to the applicable cabling table.
- Repeat these steps for each existing rack, R1 to Rn.
- Confirm each switch is available and connected.
For each switch in racks R1, R2, …, Rn, Rn+1, confirm the output for the switch
show interface status
command showsconnected
and100G
.When run from a spine switch, the output should be similar to the following:
rack1sw-roces0# show interface status -------------------------------------------------------------------------------- Port Name Status Vlan Duplex Speed Type -------------------------------------------------------------------------------- mgmt0 -- connected routed full 1000 -- -------------------------------------------------------------------------------- Port Name Status Vlan Duplex Speed Type -------------------------------------------------------------------------------- ... Eth1/5 RouterPort5 connected routed full 100G QSFP-100G-CR4 Eth1/6 RouterPort6 connected routed full 100G QSFP-100G-SR4 Eth1/7 RouterPort7 connected routed full 100G QSFP-100G-CR4 Eth1/8 RouterPort8 connected routed full 100G QSFP-100G-SR4 Eth1/9 RouterPort9 connected routed full 100G QSFP-100G-CR4 Eth1/10 RouterPort10 connected routed full 100G QSFP-100G-SR4 Eth1/11 RouterPort11 connected routed full 100G QSFP-100G-CR4 Eth1/12 RouterPort12 connected routed full 100G QSFP-100G-SR4 Eth1/13 RouterPort13 connected routed full 100G QSFP-100G-CR4 Eth1/14 RouterPort14 connected routed full 100G QSFP-100G-SR4 Eth1/15 RouterPort15 connected routed full 100G QSFP-100G-CR4 Eth1/16 RouterPort16 connected routed full 100G QSFP-100G-SR4 Eth1/17 RouterPort17 connected routed full 100G QSFP-100G-CR4 Eth1/18 RouterPort18 connected routed full 100G QSFP-100G-SR4 Eth1/19 RouterPort19 connected routed full 100G QSFP-100G-CR4 Eth1/20 RouterPort20 connected routed full 100G QSFP-100G-SR4 Eth1/21 RouterPort21 xcvrAbsen routed full 100G -- ...
When run from a leaf switch, the output should be similar to the following:
rack1sw-rocea0# show interface status -------------------------------------------------------------------------------- Port Name Status Vlan Duplex Speed Type -------------------------------------------------------------------------------- mgmt0 -- connected routed full 1000 -- -------------------------------------------------------------------------------- Port Name Status Vlan Duplex Speed Type -------------------------------------------------------------------------------- ... Eth1/4 RouterPort1 connected routed full 100G QSFP-100G-CR4 Eth1/5 RouterPort2 connected routed full 100G QSFP-100G-CR4 Eth1/6 RouterPort3 connected routed full 100G QSFP-100G-CR4 Eth1/7 RouterPort4 connected routed full 100G QSFP-100G-CR4 Eth1/8 celadm14 connected 3888 full 100G QSFP-100G-CR4 ... Eth1/29 celadm01 connected 3888 full 100G QSFP-100G-CR4 Eth1/30 RouterPort5 connected routed full 100G QSFP-100G-SR4 Eth1/31 RouterPort6 connected routed full 100G QSFP-100G-SR4 Eth1/32 RouterPort7 connected routed full 100G QSFP-100G-SR4 Eth1/33 RouterPort8 connected routed full 100G QSFP-100G-SR4 ...
- Check the neighbor discovery for every switch in racks R1, R2, …, Rn, Rn+1.Log in to each switch and use the
show lldp neighbors
command. Make sure that all switches are visible and check the switch ports assignment (leaf switches: ports Eth1/4 - Eth1/7, Eth1/30 - Eth1/33; spine switches: ports Eth1/5 - Eth1/20) against the applicable cabling tables.Each spine switch should see all the leaf switches in each rack, but not the other spine switches. The output for a spine switch should be similar to the following:
Note:
The interfaces in the rightmost output column (for example,Ethernet1/5
) are different for each switch based on the applicable cabling tables.rack1sw-roces0# show lldp neighbors | grep roce rack1sw-roceb0 Eth1/5 120 BR Ethernet1/5 rack2sw-roceb0 Eth1/6 120 BR Ethernet1/5 rack1sw-roceb0 Eth1/7 120 BR Ethernet1/7 rack2sw-roceb0 Eth1/8 120 BR Ethernet1/7 rack1sw-roceb0 Eth1/9 120 BR Ethernet1/4 rack2sw-roceb0 Eth1/10 120 BR Ethernet1/4 rack3sw-roceb0 Eth1/11 120 BR Ethernet1/5 rack3sw-roceb0 Eth1/12 120 BR Ethernet1/7 rack1sw-rocea0 Eth1/13 120 BR Ethernet1/5 rack2sw-rocea0 Eth1/14 120 BR Ethernet1/5 rack1sw-rocea0 Eth1/15 120 BR Ethernet1/7 rack2sw-rocea0 Eth1/16 120 BR Ethernet1/7 rack3sw-rocea0 Eth1/17 120 BR Ethernet1/5 rack2sw-rocea0 Eth1/18 120 BR Ethernet1/4 rack3sw-rocea0 Eth1/19 120 BR Ethernet1/7 rack3sw-rocea0 Eth1/20 120 BR Ethernet1/4 ...
Each leaf switch should see the spine switch in every rack, but not the other leaf switches. The output for a leaf switch should be similar to the following:
Note:
The interfaces in the rightmost output column (for example,Ethernet1/13
) are different for each switch based on the applicable cabling tables.rack1sw-rocea0# show lldp neighbors | grep roce rack3sw-roces0 Eth1/4 120 BR Ethernet1/13 rack1sw-roces0 Eth1/5 120 BR Ethernet1/13 rack3sw-roces0 Eth1/6 120 BR Ethernet1/15 rack1sw-roces0 Eth1/7 120 BR Ethernet1/15 rack2sw-roces0 Eth1/30 120 BR Ethernet1/17 rack2sw-roces0 Eth1/31 120 BR Ethernet1/13 rack3sw-roces0 Eth1/32 120 BR Ethernet1/17 rack2sw-roces0 Eth1/33 120 BR Ethernet1/15 ...
- Power on all the servers in the new rack (Rn+1).
- For each rack, confirm the multi-rack cabling by running the
verify_roce_cables.py
script.Refer to My Oracle Support Doc ID 2587717.1 for download and usage instructions.
Check the output of the
verify_roce_cables.py
script against the applicable cabling tables. Also, check that output in theCABLE OK?
columns contains theOK
status.When running the script, two input files are used, one for nodes and one for switches. Each file should contain the servers or switches on separate lines. Use fully qualified domain names or IP addresses for each server and switch.
The following output is a partial example of the command results:
# ./verify_roce_cables.py -n nodes.rack1 -s switches.rack1 SWITCH PORT (EXPECTED PEER) LEAF-1 (rack1sw-rocea0) : CABLE OK? LEAF-2 (rack1sw-roceb0) : CABLE OK? ----------- -------------- --------------------------- : -------- ----------------------- : --------- Eth1/4 (ISL peer switch) : rack1sw-roces0 Ethernet1/17 : OK rack1sw-roces0 Ethernet1/9 : OK Eth1/5 (ISL peer switch) : rack1sw-roces0 Ethernet1/13 : OK rack1sw-roces0 Ethernet1/5 : OK Eth1/6 (ISL peer switch) : rack1sw-roces0 Ethernet1/19 : OK rack1sw-roces0 Ethernet1/11: OK Eth1/7 (ISL peer switch) : rack1sw-roces0 Ethernet1/15 : OK rack1sw-roces0 Ethernet1/7 : OK Eth1/12 (celadm10) : rack1celadm10 port-1 : OK rack1celadm10 port-2 : OK Eth1/13 (celadm09) : rack1celadm09 port-1 : OK rack1celadm09 port-2 : OK Eth1/14 (celadm08) : rack1celadm08 port-1 : OK rack1celadm08 port-2 : OK ... Eth1/15 (adm08) : rack1dbadm08 port-1 : OK rack1dbadm08 port-2 : OK Eth1/16 (adm07) : rack1dbadm07 port-1 : OK rack1dbadm07 port-2 : OK Eth1/17 (adm06) : rack1dbadm06 port-1 : OK rack1dbadm06 port-2 : OK ... Eth1/30 (ISL peer switch) : rack2sw-roces0 Ethernet1/17 : OK rack2sw-roces0 Ethernet1/9 : OK Eth1/31 (ISL peer switch) : rack2sw-roces0 Ethernet1/13 : OK rack2sw-roces0 Ethernet1/5 : OK Eth1/32 (ISL peer switch) : rack2sw-roces0 Ethernet1/19 : OK rack2sw-roces0 Ethernet1/11: OK Eth1/33 (ISL peer switch) : rack2sw-roces0 Ethernet1/15 : OK rack2sw-roces0 Ethernet1/7 : OK
- Verify the RoCE Network Fabric operation by
using the
infinicheck
command.Use the following recommended command sequence. In each command,
hosts.lst
contains a list of database server RoCE Network Fabric IP addresses (2 RoCE Network Fabric IP addresses for each database server), andcells.lst
contains a list of RoCE Network Fabric IP addresses for the storage servers (2 RoCE Network Fabric IP addresses for each storage server).-
Use
infinicheck
with the-z
option to clear the files that were created during the last run of theinfinicheck
command. For example:# /opt/oracle.SupportTools/ibdiagtools/infinicheck -g hosts.lst -c cells.lst -z
-
Use
infinicheck
with the-s
option to set up user equivalence for password-less SSH across the RoCE Network Fabric. For example:# /opt/oracle.SupportTools/ibdiagtools/infinicheck -g hosts.lst -c cells.lst -s
-
Finally, verify the RoCE Network Fabric operation by using
infinicheck
with the-b
option, which is recommended on newly imaged machines where it is acceptable to suppress thecellip.ora
andcellinit.ora
configuration checks. For example:# /opt/oracle.SupportTools/ibdiagtools/infinicheck -g hosts.lst -c cells.lst -b INFINICHECK [Network Connectivity, Configuration and Performance] #### FABRIC TYPE TESTS #### System type identified: RoCE Verifying User Equivalance of user=root from all DBs to all CELLs. #### RoCE CONFIGURATION TESTS #### Checking for presence of RoCE devices on all DBs and CELLs [SUCCESS].... RoCE devices on all DBs and CELLs look good Checking for RoCE Policy Routing settings on all DBs and CELLs [SUCCESS].... RoCE Policy Routing settings look good Checking for RoCE DSCP ToS mapping on all DBs and CELLs [SUCCESS].... RoCE DSCP ToS settings look good Checking for RoCE PFC settings and DSCP mapping on all DBs and CELLs [SUCCESS].... RoCE PFC and DSCP settings look good Checking for RoCE interface MTU settings. Expected value : 2300 [SUCCESS].... RoCE interface MTU settings look good Verifying switch advertised DSCP on all DBs and CELLs ports ( ) [SUCCESS].... Advertised DSCP settings from RoCE switch looks good #### CONNECTIVITY TESTS #### [COMPUTE NODES -> STORAGE CELLS] (60 seconds approx.) (Will walk through QoS values: 0-6) [SUCCESS]..........Results OK [SUCCESS]....... All can talk to all storage cells [COMPUTE NODES -> COMPUTE NODES] ...
-
- After cabling the racks together, proceed to Configuring the New Hardware to finish the configuration of the new rack.