10.3.2.4 Parameters

CONV
The generic parameter CONV is mandatory for this server type, and must be defined as CONV=Y, because ARTSTRN is non-transactional.
minn and maxn
Specify respectively the initial and maximum number of servers with this configuration to start. For more information see the UBBCONFIG section in the Section 5 - File Formats, Data Descriptions, MIBs, and System Processes Reference.
CLOPT options
The following CLOPTrun-time parameters are recognized:
-s SystemID
Mandatory argument, see CICS SYSID Argument.
-l GroupList
Mandatory option, see Static List of Groups Argument.
-a Application_ID
Optional argument, see CICS Application ID Argument.
-L List_name(s)
Mandatory argument, see Dynamic List of Groups Argument.
--IMSDB -x -o host:port:dra
Optional argument, see IMS DB Argument.