Known Issues
This table lists OCSBC known issues in version S-CZ8.1.0. You can reference known issues by Service Request number and you can identify the issue, any workaround, when the issue was found, and when it was fixed using this table. Issues not carried forward in this table from previous Release Notes are not relevant to this release. You can review delivery information, including defect fixes in this release's Build Notes.
ID | Description | Found In | Fixed In | |
---|---|---|---|---|
29937232 |
GW unreachable and NetBufCtrl MBUFF errors - This can result in system instability including crash, gw-unreachable and redundancy issues. System will switchover if in HA. Show Buffers output will normally show an increase of errors reported in the NetBufCtrl field due to mbuf’s not being freed. |
S-Cz8.1.0 | S-Cz8.1.0m1p18 | |
None |
This version's enhancement to SMP-Aware Task Load Limiting, which adds a second parameter to the sip-config load-limit option, is currently not supported. |
SCZ740 | TBD | |
24574252 |
The show interfaces brief command incorrectly shows pri-util-addr information in its output. | SCZ740 | TBD | |
26790731 |
Running
commands with very long output, such as the "show support-info" command, over
an OVM virtual console might cause the system to reboot.
Workaround: You must run the "show support-info" command only over SSH. |
SCZ800 | TBD | |
26338219 | The packet-trace remote command does not work with IPv6. | SCZ740 | TBD | |
26497348 |
When operating in HA mode, the OCSBC may display extraneous "Contact ID" output from the show sipd endpoint-ip command. You can safely ignore this output. | SCZ800 | TBD | |
26258705 |
The show sipd srvcc command does not display the correct number of unsuccessful aSRVCC calls. | SCZ800 | TBD | |
26598075 |
When running on the Acme Packet 4600, the OCSBC sends a 200OK with IPv4 media address for call flows with offerless INVITES and the OCSBC configured with add-sdp-invite=invite and ALTC configured for IPv6 on the egress. | SCZ800 | TBD | |
26559988 |
In call flows that include dual ALTC INVITEs from the callee, and subsequent Re-INVITEs that offer and ALTC with IPv6 video, the OCSBC may not include the m lines in the SDP presented to the end stations during the Re-INVITE sequence. This results in the call continuing to support audio, but the video failing. | SCZ800 | TBD | |
26313330 |
In some early media call flows, the OCSBC may not present the correct address for RTP causing the call to fail. | SCZ800 | SCZ800p2, SCZ740m1p6 | |
26281599 |
The system
feature provided by the
phy-interfaces
overload-protection
parameter and
overload-alarm-threshold
sub-element is not functional. Specifically, enabling the protection and
setting the thresholds does not result in trap and trap-clear events based on
the interface's traffic load.
The applicable ap-smgmt.mib SNMP objects include:
|
SCZ720 | SCZ8.2.0 | |
25144010 |
When an OCSBC operating on an Acme Packet 6300 fails over, the secondary can successfully add new ACL entries, but it also retains old ACL entries that it should have deleted. | SCZ740p1 |
SCZ810 SCZ740M1 |
|
|
Re-balancing is unavailable on the OCSLB when running an Acme Packet 6300 as a cluster member. Set the SLB cluster-config, auto-rebalance parameter to disabled to use an Acme Packet 6300 as a cluster member from that SLB. | SCZ730 | TBD | |
21805139 |
RADIUS stop records for IWF calls may display inaccurate values. | SCZ730b6 | TBD | |
24809688 |
Media interfaces configured for IPv6 do not support multiple VLANs. | SCZ730 | TBD | |
SIP-H323 hairpin calls with DTMF tone indication interworking is not supported. | S-CZ720 | TBD | ||
The
OCSBC stops responding
when you configure an H323 stack supporting SIP-H323-SIP calls with the
max-calls parameter
set to a value that is less than the
q931-max-calls
parameter.
Workaround: For applicable environments, configure the H323 stack max-calls parameter to a value that is greater than its q931-max-calls parameter. |
S-CZ740 | TBD | ||
HA Redundancy is not supported for H.323 calls. | TBD | |||
21341383 |
If after upgrading to a S-CZ7.4.0 OCSR software image and its corresponding 7.3 stage3 boot loader, you decide to downgrade to a pre- S-CZ7.3.0 product release, you must install the corresponding 7.2 stage3 boot loader before rebooting with the older image. |
TBD | ||
23756306 |
When the session-router is configured with a operation-mode of session, it does not correctly clear sessions. |
S-Cz7.2.0 | TBD | |
23253731 |
After an HA switchover, the new standby OCSBC retains some IMS-AKA subscriber TCP sockets. You can clear these sockets by rebooting the OCSBC. | SCZ730M2 | TBD | |
26183767 |
When operating in HA mode and handling large traffic loads, the active OCSBC stops responding when you restore large configurations that are different from the configuration the active is currently running. The systems subsequently goes out of service. | SCZ800 |
SCZ740m1p1, SCZ800p1 |
|
21975038 | MSRP File Transfer is not supported on the Acme Packet 4600, 6100, 6300, and 6350. | SCZ810 | SCZ810p1 | |
27579686 | TSM is not supported in this release. | SCZ810 | SCZ810p1 | |
27699451 |
Oracle has qualified the QSFP interface for the OCSR operating over the Oracle X7-2 platform for a single QSFP port operating in 4-port mode. Specifically, 4 media interfaces successfully map to the second port of the QSFP interface using a Hydra cable as physical connections to 10G switch ports. | SCZ810 | TBD | |
27811129 |
When upgrading an OCSBC from a version that uses License Keys to enable CODECs, you must reboot the system after setting any CODEC entitlements to override the License Keys. | SCZ810 | TBD | |
27539750 |
When trying to establish a connection between the SBC and your network, while using TLS version 1.2, the SBC may reject the connection. Workaround: You may need to adjust your cipher list. |
SCZ810 | TBD | |
27911939 |
When running the OCSBC over the KVM hypervisor and using SR-IOV interface mode, the system fails over when all of following conditions are in effect:
|
SCZ810 | TBD | |
28062411 | Calls that require SIP/PRACK interworking as invoked by the 100rel-interworking option on a SIP interface do not work in pooled transcoding architectures. | SCZ740 | SCZ810m1 | |
28071326 | Calls that require LMSD interworking as invoked by the lmsd-interworking option on a SIP interface do not work in pooled transcoding architectures. During call establishment, when sending the 200 OK back to the original caller, the cached SDP is not included. | SCZ740 | SCZ810m1 | |
None | IPSec is not
supported on the Acme Packet 3900 and VNF in the CZ8.1.0 release. You must
upgrade to CZ8.1.0p1 to get this support. After you upgrade to CZ8.1.0p1, do
the following:
|
CZ810 | CZ810p1 | |
28305575 | On VNFs, the system erroneously displays the IPSEC entitlement under "Keyed (Licensed) Entitlements." The error does not affect any functionality and you do not need to do anything. | CZ810 | CZ820 | |
28367500 |
When operating the OCSBC on the Acme Packet 6300, the traceroute command does not show hops for an IPv6 traceroute that does not reach the target address. The system successfully displays hops when the traceroute reaches the target and for IPv4 traceroutes. | CZ810 | TBD | |
28617938 |
The
anonymize-invite
option for CommMonitor is not RTC. To see a change, you must either reboot or
toggle the admin state. The following is a general admin state toggle
procedure:
|
CZ810m1 | TBD | |
28618563 |
The system is not populating the Username AVP in Accounting Requests (ACRs) correctly. When triggered by an INVITE, these AVPs contain only the "@" sign. They do not include the username and domain name portion of the URL. | CZ810m1 | TBD | |
28659469 |
When booting
CZ8.1.0M1 on any virtual platform, not all system processes start. This known
issue only occurs on initial boot, and not in an upgrade scenario.
Workaround: Reboot the OCSBC a second time, after it initially starts. |
CZ810m1 | TBD | |
29931732 |
The embedded communications monitor probe does not send IPv6 traffic to the Oracle Communications Operations Monitor's mediation engine. | SCZ800 | TBD | |
28820258 |
When running TLS Chat on VMware-PV 4core (SSFD) + 16GB, TLS Chat sessions are gradually decreasing. When looking in Wireshark at EXFO, EXFO forwards a wrong TLS MSRP Chat payload to EXFO UAS. TCP Chat doesn't have this error. |
SCZ800 | TBC |
ID | Description | Found In | Fixed In | |
---|---|---|---|---|
27700607 |
When recording multiple transcoded streams under load, the recorder may only receive a single stream. |
N/A | N/A | |
N/A | The T.140-Baudot Relay is not excluded from pooled transcoding support. | N/A | N/A |