e-docs > Tuxedo > Messages > WSNAT Catalog List > WSNAT Messages 1000-1099 |
|
WSNAT Messages 1000-1099
1001
ERROR: Unused arguments passed to buildwsh
Description
The command line option passed to the buildwsh
command is not recognized as a valid option. This could also be caused by an extra "-
" in the command line.
Action
Examine the command line that calls buildwsh
and remove the extraneous option.
See Also
buildwsh
(1)
1002
ERROR: Unable to execute the command command_string
Description
While invoking the C compilation system to build a new Workstation Handler, an error was detected. This could happen for one of the following reasons:
cc
command returned an error while linking the new Workstation Handler.
$CC
environmental variable was not set correctly.
$CFLAGS
environmental variable has invalid options.
Action
Make sure the C compilation system is present on your machine. Make sure there is enough disk space available for the new Workstation Handler. This should be roughly the same as the existing WSH
and the added object files. Examine the $CC
and $CFLAGS
variables and, if set, make sure the options are correct for your C compilation environment.
See Also
cc
(1) in UNIX system reference manuals, buildwsh
(1)
1004
ERROR: Memory allocation failure
Description
An attempt dynamically to allocate memory from the operating system using malloc
failed.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine. Increase the space on the swap device.
See Also
malloc
(3) in UNIX system reference manuals
1008
ERROR: Could not establish listening address on network string
Description
This error occurs if the WSH
or the WSL
cannot advertise its listening address on the network. This could happen for one of the following conditions.
The format of the address supplied to the WSL
is incorrect. If the address format is incorrect, the network provider will be unable to advertise the address and the request fails.
The address used in the -n
command line option to the WSL
is already in use by another process. For TCP/IP, this can be verified by using the netstat command.
The system has run out of network addresses for the WSH
. The WSH
requests a new address from the system. If there are no addresses available, the request is rejected.
A previously used address has not completed the close sequence. This occurs if the WSL
or WSH
was killed in an abortive manner such as kill -9. Some transports (among them, TCP/IP) keep the connection open for an "implementation dependent" time to flush the existing data on the buffered network connection.
Action
To correct the problem, match one of the following solutions with the problem descriptions above:
0x0002ppppaaaaaaaa
. This is a hexadecimal representation of the TCP/IP address, where pppp
is a unique port number and aaaaaaaa
is the IP dotted number in the /etc/hosts
file for the machine on which the WSL
will run.
See Also
netstat
(3) in UNIX system reference manuals, Administering the BEA TUXEDO System
1010
ERROR: Couldn't convert buffer to current release format
Description
This error occurs if a Workstation client and the native UNIX system machine are of different TUXEDO System/T releases and the message is from an older release. The error can also occur if the message received by the WSH
or WSL
is corrupted.
Action
Contact BEA Customer Support.
1011
ERROR: Couldn't convert buffer to native site format
Description
The WSH
was unable to convert a message from a workstation client format to the native format. This indicates that the buffer type is unknown to the WSH
.
Action
Check the userlog for a message indicating the nature of the failure (in particular, the type and subtype of the buffer that could not be converted). It may be necessary to rebuild the WSH
using buildwsh
to include additional application buffer types.
See Also
buildwsh
(1)
1017
ERROR: Invalid data length, data not self describing
Description
Pre-processing of the message being sent to the workstation client by the presend function for the buffer type failed.
Action
Check the userlog for additional messages indicating why the pre-processing failed. If the buffer type or the presend function is provided by the application, contact your system administrator. If this is one of the TUXEDO System/T-provided buffer types, contact BEA Customer Support.
See Also
typesw
(5)
1018
ERROR: Invalid data length of 0, data not self describing
Description
Pre-processing of the message being sent to the workstation client by the presend function for the buffer type returned 0. This indicates that a message length of 0 was presented by the application and the buffer type is not self-describing, such that the presend function cannot infer the desired transfer length.
Action
The application must provide a length for sending messages of the particular buffer type.
See Also
typesw
(5)
1019
ERROR: Message conversion to workstation format failed
Description
The WSH
was unable to convert a message from a native format to workstation client format.
Action
This error should not occur. Contact BEA Customer Support.
1023
WARN: No client context space available in handler
Description
While setting up a connection for a new workstation client, the WSH
ran out of room to keep context for clients.
Action
This error should occur rarely since the WSL
transfers control of workstation client connections to WSH
programs based on their current degree of multiplexing. Contact BEA Customer Support.
See Also
WSL
(5)
1024
ERROR: Memory allocation failure
Description
An attempt dynamically to allocate memory from the operating system using malloc
failed.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine. Increase the space on the swap device.
See Also
malloc
(3) in UNIX system reference manuals
1025
ERROR: Expected numeric argument to -x option
Description
An invalid argument was passed to the Workstation Listener, WSL
, command line option. The argument to the -x
option, the degree of multiplexing, needs to be numeric. This error causes the Workstation Listener not to be booted.
Action
Make sure the argument to the -x
option is numeric.
See Also
WSL
(5)
1026
ERROR: Handler received unexpected message
Description
The WSH
received a message without a client context (that is, intended for the Workstation Handler) that is not in the right format (it is not a workstation message).
Action
The message will be ignored. Contact BEA Customer Support.
1027
ERROR: Handler received unexpected opcode 0xcode
Description
The WSH
received a message without a client context (that is, intended for the Workstation Handler) that has an unrecognized operation code (normally, a shutdown message from the WSL
).
Action
The message will be ignored. Contact BEA Customer Support.
1028
WARN: Couldn't change to client context context_number, continuing
Description
The Workstation Handler encountered an error switching to the context of a client when dropping all connections during shutdown.
Action
The connection is ignored. Contact BEA Customer Support.
1029
ERROR: Sending of reply message to client failed
Description
While sending a reply message to a client, the operation failed.
Action
Check the userlog for messages indicating the nature of the failure. It may indicate that the client is no longer accessible (either the network or machine may have failed). Contact BEA Customer Support.
1030
INFO: Work Station Handler joining application
Description
This message indicates that a WSH
process was started by the WSL
, based on the command line options for the listener and the current demand by workstation clients.
Action
No action required.
See Also
WSL
(5)
1031
ERROR: Invalid command line argument 'arg' ignored
Description
An illegal command line option was found in the command line options for the WSH
.
Action
This should be a rare event since the WSH
is started by the WSL
(it is not started directly by the administrator). Contact BEA Customer Support.
See Also
WSL
(5)
1032
ERROR: Memory allocation failure
Description
An attempt dynamically to allocate memory from the operating system using malloc
failed.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine. Increase the space on the swap device.
See Also
malloc
(3) in UNIX system reference manuals
1033
ERROR: Memory allocation failure
Description
An attempt dynamically to allocate memory from the operating system using malloc
failed.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine. Increase the space on the swap device.
See Also
malloc
(3) in UNIX system reference manuals
1034
ERROR: Failed to attach to shared memory for listener table, errno = errno_val
Description
The Workstation Handler, WSH
, failed in an attempt to attach a shared memory segment.
Action
This is an operating system error. Check the value of errno_val for an indication of the problem.
1035
ERROR: Handler table entry already occupied by pid
Description
The WSL
started a WSH
and assigned it a slot that is already occupied by another WSH
process with process identifier pid.
Action
Contact BEA Customer Support.
See Also
WSL
(5)
1036
ERROR: Network provider returns a zero length network address, can't establish network address
Description
The length of the network address that the WSH
is using to establish a connection is 0. This is not valid (and should not occur).
Action
Contact BEA Customer Support.
1037
ERROR: Can't synchronize with /WS listener ... continuing
Description
The connection between the WSL
and the WSH
that it is executing was lost by the forked WSH
process. The pipe with WSL
was lost and may be due to the WSL
process being killed.
Action
No action required, although the cause of WSL
dying should be investigated if not known.
See Also
WSL
(5)
1038
WARN: Couldn't change to client context index, continuing
Description
The Workstation Handler encountered an error switching to the context of a client when dropping all connections during shutdown.
Action
The connection is ignored. Contact BEA Customer Support.
1039
WARN: Can't use TPGETANY flag with tpcall()
Description
The workstation client called tpcall
with the TPGETANY
option. This is not valid, and TPEINVAL
will be returned to the application.
Action
No action required.
See Also
tpcall
(3)
1040
WARN: tpsprio() call failed, tperrno = tperrno_val
Description
A call to tpsprio
in the WSH
on behalf of the workstation client failed with tperrno set to tperrno_val.
Action
No action required.
See Also
tpsprio
(3c)
1041
ERROR: Memory allocation failure
Description
An attempt dynamically to allocate memory from the operating system using malloc
failed.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine. Increase the space on the swap device.
See Also
malloc
(3) in UNIX system reference manuals
1042
ERROR: tpcall() call failed, tperrno = tperrno_val
Description
A call to tpcall
in the WSH
on behalf of the workstation client failed with tperrno set to tperrno_val.
Action
No action required.
See Also
tpcall
(3c)
1043
ERROR: tpacall() call failed, tperrno = tperrno_val
Description
A call to tpacall
in the WSH
on behalf of the workstation client failed with tperrno set to tperrno_val.
Action
No action required.
See Also
tpacall
(3)
1044
ERROR: tpgprio() call failed, tperrno = tperrno_val
Description
A call to tpgprio
in the WSH
on behalf of the workstation client failed with tperrno set to tperrno_val.
Action
No action required.
See Also
buildwsh
(1)
1045
ERROR: Sending of reply to tpacall() call to client failed
Description
An attempt to send an acknowledgment of a tpacall
request to the Workstation Client has failed.
Action
This is an internal message. This failure indicates a problem with the network, with the Workstation, or with the Workstation client process. Contact BEA Customer Support.
1046
ERROR: Sending of reply to tpinit() call to client failed
Description
An attempt to send an acknowledgment of a tpinit
request to the Workstation Client has failed.
Action
This is an internal message. This failure indicates a problem with the network, with the Workstation, or with the Workstation client process. Contact BEA Customer Support.
1047
ERROR: Sending of reply to tpterm() call to client failed
Description
An attempt to send an acknowledgment of a tpterm
request to the Workstation Client has failed.
Action
This is an internal message. This failure indicates a problem with the network, with the Workstation, or with the Workstation client process. Contact BEA Customer Support.
1048
ERROR: Sending of error reply to call client failed
Description
An attempt to send an acknowledgment message to the Workstation Client has failed.
Action
This is an internal message. This failure indicates a problem with the network, with the Workstation, or with the Workstation client process. Contact BEA Customer Support.
1049
ERROR: Couldn't create buffer for receiving messages
Description
An attempt to create a buffer with tpalloc
failed. This buffer is used to receive messages.
Action
This error indicates a resource problem. If there is not sufficient memory to allocate buffers, the Workstation Handler process can not operate. Please contact your System Administrator for help. If machine resources are sufficient, this would indicate an internal problem with the Workstation Handler. In this case, contact BEA Customer Support.
1050
ERROR: Error switching to the handler's context
Description
The Workstation Handler was attempting to switch from a client context to the Workstation Handler context when it experienced an error.
Action
The error indicates an internal problem with the Workstation Handler. Contact BEA Customer Support.
1052
ERROR: Failed to process network event
Description
The Workstation Handler was unable to process a network event using tmnwevent
.
Action
The error indicates an internal problem with the Workstation Handler or the LIBNET
software. Contact BEA Customer Support.
1053
ERROR: Error polling network connections
Description
The Workstation Handler encountered an error polling a network connection using tmnwcpoll.
Action
The error indicates a network error. Check that the network connection to the Workstation Client has not gone down. If it has, the Workstation Client will have to rejoin the application. Contact BEA Customer Support.
1054
ERROR: Error generating network event list
Description
The Workstation Handler encountered an error polling a network connection using tmnwcpoll.
Action
The error indicates a network error. Check that the network connection to the Workstation Client has not gone down. If it has, the Workstation Client will have to rejoin the application. Contact BEA Customer Support.
1055
ERROR: Connection to unassigned WSH
rejected
Description
The connection for the Workstation Client was timed out.
Action
This situation may happen if the system or the network is very busy, or if the network has gone down. The Workstation Client should try again to join the application.
1056
WARN: Couldn't change to client context index, continuing
Description
The Workstation Handler encountered an error switching to the context of a client to do a tpterm
.
Action
This error indicates an internal problem. Contact BEA Customer Support.
1057
ERROR: Error processing message received from network
Description
The Workstation Handler encountered an error receiving a message from the network.
Action
This error could indicate a network problem or an internal System/T problem. Contact BEA Customer Support.
1058
ERROR: Received message with opcode other than init for non-existant context
Description
The Workstation Handler has received a message from a process that has not joined the application.
Action
This message indicates an internal problem in communication between the Workstation Handler and the Workstation Client. Contact BEA Customer Support.
1059
ERROR: Received network message with unknown context
Description
The Workstation Handler has received a message from a process that it does not know about.
Action
This message indicates an internal problem in communication between the Workstation Handler and the Workstation Client. Contact BEA Customer Support.
1060
ERROR: Received message with context associated with a different connection
Description
The Workstation Handler, working on behalf of one client context, has received a message intended for a different client context.
Action
This message indicates an internal problem in communication between the Workstation Handler and the Workstation Client. Contact BEA Customer Support.
1061
ERROR: Received a reply message from a workstation
Description
The Workstation Handler has received a message containing the reply protocol from a Workstation Client.
Action
A Workstation Client should never send a message with this protocol. This situation indicates an internal problem in communication between the Workstation Handler and the Workstation Client. Contact BEA Customer Support.
1062
ERROR: Sending of reply to tpbegin() call to client failed
Description
An attempt to send an acknowledgment of a tpbegin
request to the Workstation Client has failed.
Action
This is an internal message. This failure indicates a problem with the network, with the Workstation, or with the Workstation client process. Contact BEA Customer Support.
1063
ERROR: No more workstation handlers available
Description
An attempt to start a new Workstation Handler process has failed because the maximum limit of Workstation Handlers has already been started.
Action
The maximum number of Workstation Handlers specified in the configuration file have been started. In order to increase this number, the "CLOPT -M maxh
" value must be changed. This can be done in two ways: first, shut the application down and change the configuration file and reboot the application, or second, change the value dynamically with tmconfig
(1), shut down and reboot only the Workstation Listener (WSL
) server.
1064
ERROR: Error formatting command line options for handler
Description
An error was encountered formatting the argument string needed for booting a Workstation Handler.
Action
This message would occur if there are more than 256 characters in the CLOPT
string in the configuration file.
See Also
WSL
(5), servopts
(5)
1065
ERROR: Error retrieving machine table entry of the listener
Description
An error was encountered trying to get internal machine information while booting a Workstation Handler.
Action
Contact BEA Customer Support.
1066
ERROR: Work Station Handler died, attempting restart
Description
If a Workstation Handler process has died and the number of Workstation Handler processes booted is below the minimum specified in the configuration file, the BEA TUXEDO system attempts to boot a new Workstation Handler. This message is written to the userlog when this happens.
Action
Workstation Handlers should not die. If this happens, it could indicate an internal problem that requires attention. Additional Workstation Handlers may need to be booted, if the system is very busy.
1067
ERROR: Work Station Handler died, cleaning up
Description
A Workstation Handler process has died and the number of Workstation Handler processes booted is below the minimum specified in the configuration file. An attempt to boot a new Workstation Handler has failed.
Action
This could either be an operating system error or an internal BEA TUXEDO system error. In the former case, please contact your system administrator. In the latter case, contact BEA Customer Support.
1068
ERROR: Invalid command line argument 'arg' ignored
Description
An illegal command line option was found in the CLOPT
string.
Action
Check the BEA TUXEDO Reference Manual for correct options.
See Also
WSL
(5), servopts
(5)
1069
ERROR: Sending of reply to tpbroadcast() or tpnotify() call to client failed
Description
An attempt to send an acknowledgment of a tpbroadcast
or tpnotify
request to the Workstation Client has failed.
Action
Contact BEA Customer Support.
1070
ERROR: Cannot boot WSL
with MAXWSCLIENTS for machine set to 0
Description
The Workstation Listener process has failed to boot because the MAXWSCLIENTS
parameter was not specified in the configuration file.
Action
The MAXWSCLIENTS
parameter must be specified either in the RESOURCES section or in the *MACHINES section of the configuration file.
1071
ERROR: Memory allocation failure
Description
The Workstation Listener failed in an attempt to create a buffer for storing Workstation Handler information.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine. Increase the space on the swap device.
See Also
malloc
(3) in UNIX system reference manuals
1072
ERROR: Memory allocation failure
Description
The Workstation Listener failed in an attempt to create a buffer for storing a device name.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine. Increase the space on the swap device.
See Also
malloc
(3) in UNIX system reference manuals
1073
ERROR: Memory allocation failure
Description
The Workstation Listener failed in an attempt to create a buffer for storing a Workstation Handler's name.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine. Increase the space on the swap device.
See Also
malloc
(3) in UNIX system reference manuals
1074
ERROR: Memory allocation failure
Description
The Workstation Listener failed in an attempt to create a buffer for storing a network address.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine. Increase the space on the swap device.
See Also
malloc
(3) in UNIX system reference manuals
1075
ERROR: Can't get machine entry for listener
Description
The Workstation Listener encountered an error attempting to read the *MACHINES entry from the configuration file.
Action
Make sure the TUXCONFIG
file has not been removed or corrupted. If this is not the problem, contact BEA Customer Support.
1076
ERROR: Failed to create to shared memory for listener table, errno = errno_val
Description
The Workstation Listener failed in an attempt to create a shared memory segment.
Action
This is an operating system error. Check the value of errno_val for an indication of the problem.
See Also
Uunix_err
(3c)
1077
ERROR: Failed to update server table entry, tperrno = tperrno_val
Description
The Workstation Listener failed in an attempt to update the Bulletin Board.
Action
Check that the shared memory segment that contains the Bulletin Board has not been removed. If it has, then the application will need to be rebooted. Otherwise, this error would indicate an internal error. In this case, contact BEA Customer Support.
See Also
tperrno
(5)
1078
ERROR: Failed to attach to shared memory for listener table, errno = errno_val
Description
The Workstation Listener failed in an attempt to attach a shared memory segment.
Action
This is an operating system error. Check the value of errno_val for an indication of the problem.
See Also
tperrno
(5)
1079
ERROR: Error starting minimum number of handlers
Description
The Workstation Listener encountered an error attempting to boot the minimum number of Workstation Handlers.
Action
This could be an operating system error. Perhaps there are too many processes running. Or, this could be an internal error. Check the log file for other messages relating to this message. In this case, contact BEA Customer Support.
1080
ERROR: Error polling network connections
Description
The Workstation Listener encountered an error polling a network connection.
Action
This error indicates a network error. Check with your system administrator to see if the network is down.
1082
ERROR: Error adding connection request to event list
Description
The Workstation Listener was unable to allocate space on the event list.
Action
This error indicates a resource problem. If there is not sufficient memory to allocate buffers, the Workstation Listener process can not operate. Please contact BEA Customer Support for help.
1083
ERROR: Error assigning connection request, can't create any more handlers
Description
The Workstation Listener was unable to start a new Handler.
Action
The most likely problem is that the maximum number of Workstation Handlers specified in the configuration file have been started. In order to increase this number, the CLOPT -M maxh
value must be changed. This can be done in two ways: first, shut the application down and change the configuration file and reboot the application, or second, change the value dynamically with tmconfig
(1), shut down and reboot only the Workstation Listener (WSL
) server.
Another possible source of the problem could be that the number of processes allowable by a user (ulimit
) has been reached. If this is the case, consult with your System Administrator to increase this limit.
1086
ERROR: Message conversion to release rel format failed
Description
The Workstation Handler/Listener was unable to change the release structure to 4.2.
Action
Contact BEA Customer Support.
1088
ERROR: tpinit() failed, tperrno = tperrno_val
Description
The tpinit
(3c) function call used to connect a workstation client to a TUXEDO System/T application has failed. Further information about the cause of the failure is provided by the value of tperrno. By examining the <atmi.h>
header file, this numeric tperrno
value may be converted to a symbolic value. Potential causes of each such symbolic value are listed on the tpinit
(3c) reference page.
Action
Refer to the tpinit
(3c) reference page for causes of the specific tperrno
value that was reported to the application. Eliminate the potential causes of such an error and retry the failed operation.
See Also
tpinit
(3c), tperrno
(5)
1089
ERROR: tpscmt() failed, tperrno = tperrno_val
Description
While attempting to commit a transaction on behalf of a workstation client, the workstation handler process was unable to set the transaction commit control characteristic for the transaction to TP_CMT_LOGGED
. (For further information on the transaction commit control characteristic, refer to the tpscmt
(3c) reference page.) For this reason, the attempt to commit the transaction failed.
Action
Since the transaction cannot be committed, it will be necessary for the user to abort it. The value of tperrno
and immediately preceding messages in the userlog may provide further information as to the cause of the error.
See Also
tpabort
(3c), tpcommit
(3c), tpscmt
(3c), tperrno
(5)
1090
ERROR: tpscmt() failed, tperrno = tperrno_val
Description
While attempting to commit a transaction on behalf of a workstation client, the workstation handler process was unable to set the transaction commit control characteristic for the transaction to TP_CMT_COMPLETE
. (For further information on the transaction commit control characteristic, refer to the tpscmt
(3c) reference page.) For this reason, the attempt to commit the transaction failed.
Action
Since the transaction cannot be committed, it will be necessary for the user to abort it. The value of tperrno
and immediately preceding messages in the userlog may provide further information as to the cause of the error.
See Also
tpabort
(3c), tpcommit
(3c), tpscmt
(3c), tperrno
(5)
1096
ERROR: Sending of reply to tpcommit() call to client failed
Description
An attempt to send an acknowledgment of a tpcommit
request to the Workstation Client has failed.
Action
This is an internal message. This failure indicates a problem with the network, with the Workstation, or with the Workstation client process. Contact BEA Customer Support.
1097
ERROR: Sending of reply to tpabort() call to client failed
Description
An attempt to send an acknowledgment of a tpabort
request to the Workstation Client has failed.
Action
This is an internal message. This failure indicates a problem with the network, with the Workstation, or with the Workstation client process. Contact BEA Customer Support.
1099
ERROR: Could not find correct number of active handlers, found num1, expected num2
Description
While being restarted after the death of a previous workstation listener process, the workstation listener found an inconsistency in the existing workstation specific shared memory regarding the number of workstation handler processes. The WSL
attempts to shut down any associated WSH
processes that it knows about, removes the inconsistent shared memory, and exits.
Action
The administrator should check for any stray workstation handler (WSH
) processes associated with this particular workstation listener, and see that they are manually terminated. The administrator may then re-boot the workstation listener process.
![]() |
![]() |
![]() |
![]() |
||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |