e-docs > Tuxedo > Messages > TUXNT Catalog List > TUXNT Messages 0-99 |
|
TUXNT Messages 0-99
1
ERROR: Memory allocation failure
Description
An internal BEA TUXEDO system IPC error has occurred. An attempt to allocate memory for semaphore list from the operating system using malloc
failed.
Action
Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
2
ERROR: Cannot open semaphore 'name': error
Description
An internal BEA TUXEDO system IPC error has occurred. The OpenSemaphore
system function call which returns a handle of an existing named semaphore object failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
3
ERROR: Cannot wakeup proc pid: error
Description
An internal BEA TUXEDO system IPC error has occurred. The ReleaseSemaphore
system function call to wake up a process failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
4
ERROR: Cannot access ipc server (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The WaitNamePipe
system function call which waits forever on BEA TUXEDO system IPC Server Pipe (IPC_SERVER_PIPE) until it is available to be connected to failed. The BEA TUXEDO system IPC Server cannot be accessed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors. Check to see if the BEA TUXEDO system IPC Helper service has been stopped by going into Control Panel Service applet. If so, restart the BEA TUXEDO system IPC Helper service from the Control Panel of your machine.
5
ERROR: Cannot access server pipe (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The CreateFile
system function call which is used to open the BEA TUXEDO system IPC Server Pipe (IPC_SERVER_PIPE) for read or write failed. INVALID_HANDLE_VALUE has been returned from CreateFile
. The BEA TUXEDO system IPC Server cannot be accessed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors. Check to see if the BEA TUXEDO system IPC Helper service has been stopped by going into Control Panel Service applet. If so, restart the BEA TUXEDO system IPC Helper service from the Control Panel of your machine. Also, check the permissions on the BEA TUXEDO system IPC Helper service.
6
ERROR: Cannot set pipe state (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The SetNamedPipeHandleState
system function call which sets the read mode of the BEA TUXEDO system IPC Server Pipe (IPC_SERVER_PIPE) failed. Data is set to be read from the pipe as a stream of messages.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
7
ERROR: Cannot contact ipc server (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The TransactNamedPipe
system function call which combines a write operation and a read operation into a single network operation from the BEA TUXEDO system IPC Server Pipe (IPC_SERVER_PIPE) failed. The BEA TUXEDO system IPC server cannot be contacted.
Action
This function fails if the server did not create the pipe as a message-type pipe or if the pipe handle is not in message-read mode. Also, the function returns ERROR_MORE_DATA if the read buffer specified in the call is not large enough to hold the entire message. The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
8
ERROR: Invalid reply length from server (read/reply)
Description
An internal BEA TUXEDO system IPC error has occurred. The reply buffer from the BEA TUXEDO system IPC Server has invalid length after the TransactNamedPipe
system function call.
Action
Please check Microsoft documentation for details on TransactNamedPipe
.
9
WARN: Reusing existing shared memory segment 'IPCSEG'
Description
Existing shared memory segment will be reused.
Action
No action required.
10
WARN: Existing parameter value = configuration, cannot change to actual
Description
When creating BEA TUXEDO system IPC, warning messages are issued if existing values do not match with default configuration values for all parameters of the BEA TUXEDO system IPC Helper service.
Action
Check your registry database for all your BEA TUXEDO system IPC parameters.
11
ERROR: Memory allocation failure
Description
An internal BEA TUXEDO system IPC error has occurred. An attempt to allocate memory for an anonymous security descriptor from the operating system using malloc
failed.
Action
Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
12
ERROR: Cannot initialize security descriptor (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The InitializeSecurityDescriptor
system function call which initializes a security descriptor to have no system Access Control List (ACL), no discretionary Access Control List (ACL), no owner, no primary group and all control flags set to NULL failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
13
ERROR: Cannot set ACL to security descriptor (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The SetSecurityDescriptorDacl
system function call which sets information in a discretionary access-control list (ACL) failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
14
ERROR: Cannot create IPC mutex (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The CreateMutex
system function call which creates the BEA TUXEDO system IPC mutex object failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
15
ERROR: Cannot create shared memory 'IPCSEG' (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The CreateFileMapping
system function call which creates the BEA TUXEDO system shared memory failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
16
ERROR: Cannot access Service Manager (error)
Description
The OpenSCManager
system function call which opens a connection to the Windows NT service control manager and the ServicesActive database failed. Possible errors are the requested access to the service control manager and ServicesActive database was denied, or the ServicesActive database does not exist.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
17
ERROR: Cannot access service 'process' (error)
Description
The OpenService
system function call which opens a handle to the BEA TUXEDO system IPC service failed. The BEA TUXEDO system IPC Helper service is not accessible.
Action
This error occurs usually because the BEA TUXEDO system IPC Helper service does not exist. You need to initially run the setup program comes with the BEA TUXEDO system distribution media to install the software. As part of the installation, the BEA TUXEDO system IPC Helper service will be created. Restart the BEA TUXEDO IPC Helper service. The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
18
ERROR: Cannot start service 'process' (error)
Description
The StartService
system function call which starts the BEA TUXEDO system IPC service failed.
Action
This error occurs usually because the BEA TUXEDO system IPC Helper service does not exist. You need to initially run the setup program comes with the BEA TUXEDO system distribution media to install the software. As part of the installation, the BEA TUXEDO system IPC Helper service will be created. It is possible that the BEA TUXEDO system IPC Helper service binary (tuxipc.exe) could not be found. Check your path and registry values under \HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\BEA TUXEDO system IPC Helper\ImagePath. It is also possible that another instance of the BEA TUXEDO system IPC Helper is already running. Other possible errors are the service database is locked or the BEA TUXEDO system IPC Helper service has been disabled. Restart your BEA TUXEDO system IPC Helper service. The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
19
ERROR: Cannot query service 'process' (error)
Description
The QueryServiceStatus
system function call which retrieves the current status of the BEA TUXEDO system IPC service failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors. You might have to restart your BEA TUXEDO system IPC Helper service from your Control Panel Service applet.
20
WARN: Service 'TUXEDO IPC Helper' could not be started
Description
The BEA TUXEDO system IPC Helper service could not be started because Windows NT service manager could not be opened or the BEA TUXEDO system IPC Helper service is inaccessible. The BEA TUXEDO system IPC Helper (tuxipc.exe) will be started as a normal process rather than a service now.
Action
No action required.
21
WARN: All applications will exit when console user logs off
Description
The BEA TUXEDO system IPC Helper (tuxipc.exe) is started as a normal process rather than a service. All applications will exit when console user logs off.
Action
No action required.
22
ERROR: Cannot create ipc server process 'tuxipc.exe' (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The CreateProcess
system function call which creates the BEA TUXEDO system IPC Helper (tuxipc.exe) as a normal process rather than a service failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors. Check to see if you have tuxipc.exe already running.
23
ERROR: Cannot create sleep semaphore 'name' (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The CreateSemaphore
system function call which creates sleep semaphore object failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
24
ERROR: Cannot access ipc server pipe 'IPC_SERVER_PIPE' (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The WaitNamePipe
system function call which waits forever on the BEA TUXEDO system IPC Server Pipe (IPC_SERVER_PIPE) until it is available to be connected to failed. The BEA TUXEDO system IPC Server cannot be accessed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors. Check to see if the BEA TUXEDO system IPC Helper service has been stopped by going into Control Panel Service applet. If so, restart the BEA TUXEDO system IPC Helper service from the Control Panel of your machine.
25
WARN: Reopening existing segment 'shmid'
Description
Unable to get a BEA TUXEDO system shared memory segment. The CreateFileMapping
system function call failed with ERROR_ALREADY_EXISTS. The shared memory segment was left open after tuxipc died. Existing shared memory segment shmid will be reopened.
Action
No action required.
26
ERROR: shmat: Missing segment 'shmid'
Description
An internal BEA TUXEDO system IPC error has occurred. Unable to attach a BEA TUXEDO system shared memory segment. The OpenFileMapping
system function call failed. The shared memory segment was missing.
Action
Restart your BEA TUXEDO system IPC Helper service or reboot your machine if the problem is persistent.
27
WARN: shmdt: Cannot unmap segment
Description
Unable to detach a BEA TUXEDO system shared memory segment. The UnmapViewOfFile
system function call failed.
Action
Contact BEA Customer Support.
28
ERROR: Cannot release semaphore (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The ReleaseSemaphore
system function call which is used to wake up a thread failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
29
ERROR: Cannot create timer event (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The CreateEvent
system function call which creates timer event failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
31
ERROR: Cannot create pause event (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The CreateEvent
system function call to create pause event failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
32
ERROR: Cannot create timer start event (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The CreateEvent
system function call to create timer start event failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
33
ERROR: Cannot create timer thread (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The CreateThread
system function call to create timer thread failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
34
ERROR: Cannot wait on start event (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The WaitForSingleObject
system function call which waits forever failed on the timer start event.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
35
ERROR: Cannot send message to timer thread threadId (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The PostThreadMessage
system function call to send message to timer thread failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
39
ERROR: Memory allocation error (line line_number)
Description
An attempt to allocate memory from the operating system using malloc
failed.
Action
Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
40
ERROR: Cannot create watchdog start event (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The CreateEvent
system function call failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
41
ERROR: Cannot create watchdog thread (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The CreateThread
system function call failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
42
ERROR: Removing invalid process pid
Description
An internal BEA TUXEDO system IPC error has occurred. Process pid is no longer alive, and it will be removed.
Action
Contact BEA Customer Support.
43
ERROR: Watchdog wait failed (error)
Description
An internal BEA TUXEDO system IPC error has occurred. Waiting for the process to terminate has failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
44
ERROR: Cannot create new process event (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The CreateEvent
system function call failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
45
ERROR: Cannot create ipc data (error)
Description
An internal BEA TUXEDO system IPC error has occurred. Creating the BEA TUXEDO system IPC data has failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
46
ERROR: Cannot create server pipe 'IPC_SERVER_PIPE' (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The CreateNamedPipe
system function call to create the BEA TUXEDO system IPC Server Pipe (IPC_SERVER_PIPE) failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
47
ERROR: Pipe connect failed (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The ConnectNamedPipe
system function call to connect to the BEA TUXEDO system IPC Server Pipe (IPC_SERVER_PIPE) failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
48
ERROR: Cannot read pipe (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The ReadFile
system function call to read the BEA TUXEDO system IPC Server Pipe (IPC_SERVER_PIPE) failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
49
ERROR: Unexpected read size read/ipcop
Description
An internal BEA TUXEDO system IPC error has occurred. The ReadFile
system function call returned invalid number of bytes read.
Action
Contact BEA Customer Support.
50
ERROR: Unexpected request action
Description
An internal BEA TUXEDO system IPC error has occurred. Invalid IPC request was given to the BEA TUXEDO system IPC Helper.
Action
Contact BEA Customer Support.
51
ERROR: Cannot write to pipe (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The WriteFile
system function call to write to the BEA TUXEDO system IPC Server Pipe (IPC_SERVER_PIPE) failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
52
ERROR: Unexpected write size write/reply
Description
An internal BEA TUXEDO system IPC error has occurred. The WriteFile
system function call returned invalid number of bytes written.
Action
Contact BEA Customer Support.
53
ERROR: Cannot flush pipe (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The FlushFileBuffers
system function call to clear the buffer and write all data to the BEA TUXEDO system IPC Server Pipe (IPC_SERVER_PIPE) failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
54
WARN: Cannot disconnect pipe (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The DisconnectNamedPipe
system function call to disconnect the BEA TUXEDO system IPC Server Pipe (IPC_SERVER_PIPE) failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
55
ERROR: Cannot start IPC services (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The StartServiceCtrlDispatcher
system function call to start the BEA TUXEDO system IPC service failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors. Check to see if you have tuxipc.exe already running. Also, make sure that the ImagePath of the BEA TUXEDO system IPC Helper is set to TUXDIR\bin\tuxipc.exe in your registry.
56
ERROR: Cannot set service status (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The SetServiceStatus
system function call to set the status for the BEA TUXEDO system IPC service failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
57
ERROR: Cannot create worker thread (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The CreateThread
system function call failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
58
INFO: IPC server exiting
Description
The BEA TUXEDO system IPC Helper server is exiting.
Action
No action required.
59
ERROR: Cannot start process in background mode, cmdline=val, errno=val2
Description
An internal BEA TUXEDO system IPC error has occurred. An attempt to start the current process in background mode failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
60
ERROR: Memory allocation failure
Description
An internal BEA TUXEDO system IPC error has occurred. An attempt to allocate memory from the operating system using malloc
failed.
Action
Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
61
ERROR: Could not make pipe, errno=error
Description
An internal BEA TUXEDO system IPC error has occurred. The CreatePipe
system function call failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
62
ERROR: Could not fork, errno=error
Description
An internal BEA TUXEDO system IPC error has occurred. The CreateProcess
system function call failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
63
ERROR: Child dup error, rc=retcode, errno=error
Description
An internal BEA TUXEDO system IPC error has occurred. The _open_osfhandle system function call failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
64
ERROR: Parent dup error while saving stdout, errno=error
Description
An internal BEA TUXEDO system IPC error has occurred. The _dup system function call failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
65
WARN: pager: wait status 0xstatus, errno=error
Description
The WaitForSingleObject
system function call to wait for the child process to finish failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
66
ERROR: Cannot create process (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The CreateProcess
system function call to spawn a new process by the BEA TUXEDO system IPC service failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
67
ERROR: Could not allocate thread local storage, error number = error
Description
An internal BEA TUXEDO system IPC error has occurred. The TlsAlloc
system function call which allocates a thread local storage (TLS) index for the BEA TUXEDO system IPC lock failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
68
ERROR: Could not allocate thread local storage, error number = error
Description
An internal BEA TUXEDO system IPC error has occurred. The TlsAlloc
system function call which allocates a thread local storage (TLS) index for the BEA TUXEDO system IPC signal processing failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
71
ERROR: Memory allocation failure
Description
An attempt to allocate memory from the operating system using malloc
for buildclient failed.
Action
Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
72
ERROR: TUXDIR environment variable not set
Description
The BEA TUXEDO system environment variable TUXDIR
was not set.
Action
Set the environment variable TUXDIR
and rerun the buildclient command.
See Also
BEA TUXEDO system Installation Guide
73
ERROR: Memory allocation failure
Description
An attempt to allocate memory from the operating system for buildclient failed.
Action
Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
74
ERROR: Unused arguments passed to command
Description
Extra arguments were given to the buildclient command for building BEA TUXEDO system clients.
Action
Consult your BEA TUXEDO system documentation for valid arguments for buildclient
command.
See Also
buildclient
(1)
75
ERROR: Memory allocation failure
Description
An attempt to allocate memory from the operating system using malloc
for buildclient failed.
Action
Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
76
ERROR: Can't open tempfile filename
Description
An attempt to open a temporary file using fopen failed.
Action
Check the permissions of the file and repeat the operation.
See Also
fopen
77
ERROR: Can't execute cc_cmd
Description
The buildclient command was unable to execute the C compiler command. The C compiler command that buildclient attempted to execute is given as part of this error message.
Action
Verify that the Microsoft Visual C++ compiler has been installed on the machine, that it is executable, and that the directory containing the compiler is included in your PATH environment variable.
See Also
buildclient(1)
78
ERROR: Can't execute cc_cmd
Description
The buildclient command was unable to execute the C compiler command. The C compiler command that buildclient attempted to execute is given as part of this error message.
Action
Verify that the Microsoft Visual C++ compiler has been installed on the machine, that it is executable, and that the directory containing the compiler is included in your PATH environment variable.
See Also
buildclient(1)
94
ERROR: Cannot open registry key
Description
Unable to open the registry key for the BEA TUXEDO system Performance Monitor: \\HKEY_LOCAL_MACHINE\\SYSTEM\\CurrentControlSet\\Services\\TUXEDO IPC Helper\\Performance. The RegOpenKeyEx
system function call failed.
Action
This error occurs usually because the registry key for the BEA TUXEDO system IPC Helper service does not exist or it was not created properly. You need to initially run the setup program comes with the BEA TUXEDO system distribution media to install the software. As part of the installation, the BEA TUXEDO system IPC Helper service will be created as well as the registry keys. Other possible errors are your registry database somehow got locked. You might need to reboot the machine if the problem is persistent.
95
ERROR: Cannot obtain 'First Counter' data
Description
Unable to retrieve the "First Counter" data from the registry for the BEA TUXEDO system Performance Monitor: \\HKEY_LOCAL_MACHINE\\SYSTEM\\CurrentControlSet\\Services\\TUXEDO IPC Helper\\Performance. The RegQueryValueEx
system function call failed.
Action
This error occurs usually because the registry key for the BEA TUXEDO system IPC Helper service does not exist or it was not created properly. You need to initially run the setup program comes with the BEA TUXEDO system distribution media to install the software. As part of the installation, the BEA TUXEDO system IPC Helper service will be created as well as the registry keys. Other possible errors are your registry database somehow got locked. You might need to reboot the machine if the problem is persistent.
96
ERROR: Cannot obtain 'First Help' data
Description
Unable to retrieve the "First Help" data from the registry for the BEA TUXEDO system Performance Monitor: \\HKEY_LOCAL_MACHINE\\SYSTEM\\CurrentControlSet\\Services\\TUXEDO IPC Helper\\Performance. The RegQueryValueEx
system function call failed.
Action
This error occurs usually because the registry key for the BEA TUXEDO system IPC Helper service does not exist or it was not created properly. You need to initially run the setup program comes with the BEA TUXEDO system distribution media to install the software. As part of the installation, the BEA TUXEDO system IPC Helper service will be created as well as the registry keys. Other possible errors are your registry database somehow got locked. You might need to reboot the machine if the problem is persistent.
99
ERROR: Cannot create process maintenance thread (error)
Description
An internal BEA TUXEDO system IPC error has occurred. The CreateThread
system function call failed.
Action
The extended error information is described in error by calling GetLastError
. Please check Microsoft documentation for details on those errors.
![]() |
![]() |
![]() |
![]() |
||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |