e-docs > Tuxedo > Messages > LIBTG Catalog List > LIBTG Messages 1000-1099 |
|
LIBTG Messages 1000-1099
1000
ERROR: config file <val> not found
Description
The BEA TUXEDO/BEA TOP END gateway configuration file was not found. (This file is specified
with the -f
parameter-on
the CLOPT
line for the
gateway-in the SERVERS
section of ubbconfig
.)
Action
Create a configuration file (if one does not exist) and set the -f
(CLOPT
) parameter.
1001
WARN: unknown section <val> in val - skipping
Description
Valid sections for the gateway configuration file are:
TE_LOCAL_SERVICES
TE_REMOTE_SERVICES
Any o ther sections are ignored.
Action
The system ignores the line containing the name of the invalid section. If this behavior is acceptable, then no action is required. (Even if it is acceptable for this line to be ignored, however, it is a good idea to delete it to maintain a clean file.)
If the name is invalid because of a spelling or typing error, then correct the error.
1002
ERROR: service name <val> too long, max val characters
Description
The service name specified in the service definition file (as specified by the -f
CLOPT
parameter) contains more than
the maximum number of characters supported by the BEA TUXEDO system. The gateway will exit
gracefully.
Action
Modify the service names in the configuration file and re-boot the gateway.
1003
ERROR: syntax error in configuration file: <val>
Description
A syntax error was detected in the service definition file specified by the -f CLOPT
parameter. The gateway will
exit gracefully.
Action
Fix the indicated line and re-boot the gateway.
1004
ERROR: product name <val> too long, max val characters
Description
The product name specified in the service definition file (as specified by the -f
CLOPT
parameter) contains more than
the maximum number of characters supported by BEA TOP END. The gateway will exit
gracefully.
Action
Modify the product names in the configuration file and re-boot the gateway.
1005
ERROR: function name <val> too long, max val characters
Description
The function name specified in the service definition file (as specified by the -f
CLOPT
parameter) contains more than
the maximum number of characters supported by BEA TOP END. The gateway will exit
gracefully.
Action
Modify the function names in the configuration file and re-boot the gateway.
1006
ERROR: target name <val> too long, max val characters
Description
The target name specified in the service definition file (as specified by the -f
CLOPT
parameter) contains more than
the maximum number of characters supported by BEA TOP END. The gateway will exit
gracefully.
Action
Modify the target names in the configuration file and re-boot the gateway.
1007
ERROR: unknown tag <val> in val
Description
An unknown tag was found in the service definition file specified by the -f CLOPT
parameter. The gateway will
exit gracefully.
Action
Correct the configuration file and re-boot the gateway.
1008
ERROR: exceeded number of entries (val) supported by gateway
Description
The service definition file (specified by the -f
CLOPT
parameter) contains more entries than can be supported by the gateway. The gateway will
exit gracefully.
Action
Ei ther remove service entries from the configuration file, or configure a second gateway (with a second configuration file) and segment the services.
1009
ERROR: service <val> does not have PRODUCT defined in file val
Description
PRODUCT
is a mandatory field. It
must be specified, either on the DEFAULT
:
line or in each service entry.
Action
Add product names as appropriate and re-boot the gateway.
1010
ERROR: multiple product names not allowed in TE_LOCAL_SERVICES section
Description
The GWTE2TUX
gateway
supports a single product name. All service entries in the TE_LOCAL_SERVICES
section must have
the same product name.
Action
Modify the file so that all product names in the LOCAL_SERVICES
section are the same. If multiple products are
needed, use an additional configuration file to configure a second gateway with a
different product name.
1011
WARN: Unable to establish connection to TOP END
Description
Th egateway was unable to connect to the BEA TOP END system. The gateway needs to connect to a BEA TOP END Network Agent.
Action
Make sure that the BEA TOP END Network Agent (NA) is running and configured properly. Also make
sure that the BEA TOP END remote configuration file (as specified by the -c
CLOPT
parameter, or topendrc.cfg
by default) is
configured with the proper BEA TOP END system, machine, and port number.
1012
ERROR: Cannot allocate TOP END client DIF structure
Description
The gateway was unable to allocate the memory needed for BEA TOP END communication. The
gateway will retry the allocation as specified by the -R
CLOPT
parameter.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1013
ERROR: Sign on to TOP END failed. Error code=val(val). server exiting...
Description
The GWTUX2TE
gateway issued
a call to tp_client_signon
(to sign on to the BEA TOP END system) and the call failed.
Action
Check the description of the error code available in the tp_client_signon
(3T) entry in the BEA TOP END Reference Manual.
1014
ERROR: username and password (-u and -p) invalid or not specified
Description
The GWTUX2TE
gateway has
invalid credentials and has failed BEA TOP END au thentication.
Action
Modify the user name or password (using the -u
or -p
parameter,
respectively), or add the user_ID/password combination to the BEA TOP END security
database.
1015
ERROR: failed on TOP END receive during initialization. Error code=val(val)
Description
The GWTUX2TE
gateway failed
to receive a response from BEA TOP END for the call to tp_client_signon
.
Action
Check the description of the error code available in the tp_client_receive
(3T) entry in the BEA TOP END Reference Manual.
1016
ERROR: failed on TOP END send. retcode=val(val) extended status=val(val)
Description
The GWTUX2TE
gateway was
unable to send the message to the BEA TOP END system.
Action
Check the description of the error code available in the tp_client_send
(3T) entry in the BEA TOP END Reference Manual.
1017
ERROR: failed on TOP END receive. retcode=val(val) extended status=val
Description
The GWTUX2TE
gateway was
unable to receive a response from the BEA TOP END system.
Action
Check the description of the error code available in the tp_client_receive
(3T) entry in the BEA TOP END Reference Manual.
1018
WARN: TOP END server sent response with TP_APPL_CONTEXT. Resetting dialog
Description
The BEA TOP END server set the TP_APPL_CONTEXT
flag with the response. This flag is not supported by the gateway. The gateway sent an
error back to the server and reset the dialog. The gateway can continue processing.
Action
The TP_APPL_CONTEXT
flag is
not supported by the gateway. The application should be modified so that the flag is not
set.
1019
INFO: stale response message received from TOP END - ignoring
Description
The response that was received is apparently an orphaned response. This problem can occur when the gateway goes down and restarts. The gateway continues to search for the matching response.
Action
No action is required.
1020
ERROR: TOP END initialization Failed. Error code=val(val)
Description
The GWTUX2TE
gateway failed
on the call to tp_initialize
.
Action
Check the description of the error code available in the tp_initialize
(3T) entry in the BEA TOP END Reference Manual.
1021
ERROR: service definition file (-f )not specified. Exiting server...
Description
The -f
parameter is required
in the list of CLOPT
options for the gateway.
Action
Add the -f
parameter to the
list of CLOPT
options
for the gateway and re-boot the BEA TUXEDO system.
1022
ERROR: cannot access MIB for security info. val. Exiting server...
Description
The -u
and -g
parameters were specified for the
gateway. The gateway needs to perform a MIB look-up to obtain the appropriate security
credentials. The MIB request failed.
Action
Verify that the TMIB
service is
advertised.
1023
ERROR: cannot access MIB for security info. val. Exiting server...
Description
The -u
and -g
parameters were specified for the
gateway. The gateway needs to perform a MIB look-up to obtain the appropriate security
credentials. The MIB request failed.
Action
Verify that the TMIB
service is
advertised.
1024
ERROR: unable to allocate TOP END receive buffer. Exiting server...
Description
The gateway was unable to allocate the memory needed for BEA TOP END communication.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1026
ERROR: TOP END tp_csi_alloc Failed. Exiting server...
Description
The gateway was unable to allocate the memory needed for BEA TOP END communication.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1027
ERROR: function name not found
Description
The GWTE2TUX
gateway
received a BEA TOP END client request with a function name that is not recognized by the
gateway. The gateway sent an error to the client. It will continue processing.
Action
Check the service definition file to verify the function names.
1028
ERROR: failed to convert message to TUXEDO format
Description
The gateway was unable to convert the BEA TOP END client request into the BEA TUXEDO buffer format.
Action
Check the message in the userlog preceding this message for fur ther information. Possible symptoms are: message too large (max 30K), unsupported BEA TUXEDO buffer type.
1029
ERROR: failure attempting to reach service name (name)
Description
The GWTE2TUX
gateway was
unable to reach the specified BEA TUXEDO service. The specific error is indicated in
paren theses.
Action
Probable causes are: the service is not advertised or is suspended, or the service name advertised
by the BEA TUXEDO system (as specified in the SERVICES
section of ubbconfig
) does not match the service name in the gateway's
service definition file. Make sure the service is advertised and the service names in ubbconfig
and the service definition
file match. Also check the error value in tpacall
(3c).
1030
ERROR: failure attempting to get reply from service name (name)
Description
The GWTE2TUX
gateway was
unable to receive a response from the BEA TUXEDO service. The specific error is indicated
in paren theses.
Action
Check the error value in tpgetrply
(3c).
1031
ERROR: failed to convert message to TOP END format
Description
The gateway was unable to convert the BEA TUXEDO server response into the BEA TOP END buffer format.
Action
Check the message in the userlog preceding this message for fur ther information. Possible symptoms are: message too large (max 30K), unsupported BEA TUXEDO buffer type.
1032
ERROR: tp_server_send failed with unknown TOP END code[name]
Description
The gateway received an unknown receive code from the tp_server_send
() call. The gateway
will continue to process messages.
Action
No action is required.
1033
ERROR: tp_server_send failed with unknown TOP END code[name]
Description
The gateway received an unknown receive code from the tp_server_send
() call. The gateway
will continue to process messages.
Action
No action is required.
1034
ERROR: Conversational services not supported by gateway
Description
The gateway does not support conversation services (tpconnect
, tpsend
,
and tprecv
).
Action
BEATUXEDO clients and servers should be built to use the request/response paradigm.
1035
ERROR: transactions not supported by gateway
Description
The gateway does not support transactions (tpbegin
and tpcommit
).
Action
The client call to the BEA TOP END service should include the TPNOTRAN
flag.
1037
ERROR: Tuxedo->TopEnd service mapping not found for service name
Description
The name of the BEA TUXEDO service specified in the error message is not included in the table
for the GWTUX2TE
gateway.
Action
Check the service definition file for the gateway to see if it includes an entry for the service name.
1038
ERROR: invalid value specified for wait time (-w), Server exiting...
Description
The wait time must be greater than or equal to 0.
Action
Modify the wait time to a valid value.
1039
ERROR: can't open password file <name>, fopen errno=val. Server exiting
Description
The password file (specified by the -p
CLOPT
parameter) cannot
be accessed. Possible causes are: the file does not exist, or the permissions are not
valid.
Action
Ensurethat the file exists and is readable by the BEA TUXEDO administrator.
1040
ERROR: service definition file (-f )not specified. Server exiting...
Description
The -f
parameter is required
in the list of CLOPT
options for the gateway.
Action
Add the -f
parameter to the
list of CLOPT
options
for the gateway and re-boot the BEA TUXEDO system.
1041
ERROR: Config file (-f ) not specified, server exiting
Description
The -f
parameter is required
in the list of CLOPT
parameters for the gateway.
Action
Add the -f
parameter to the
list of CLOPT
options
for the gateway and re-boot the BEA TUXEDO system.
1042
ERROR: unable to allocate TOP END receive buffer
Description
The gateway was unable to allocate the memory needed for BEA TOP END communication.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1043
INFO: retrying connection to TOP END every val seconds
Description
The gateway was unable to connect to BEA TOP END; it will perform periodic retries. The gateway will not advertise remote services until a connection is established.
Action
No action is required.
1044
INFO: connection established to TOP END
Description
The gateway has successfully connected to BEA TOP END.
Action
No action is required.
1045
WARN: Network connection closed by TOP END
Description
The network connection has been closed for one of the following reasons: the BEA TOP END system was shut down, the NA was shut down, or the network connection was broken.
Action
If you have planned this downtime, no action is required. If you have not planned this downtime, check the BEA TOP END system and bring it up if necessary. Also check network connectivity.
1046
WARN: Network connection closed by TOP END
Description
The network connection has been closed for one of the following reasons: the BEA TOP END system was shut down, the NA was shut down, or the network connection was broken.
Action
If you have planned this downtime, no action is required. If you have not planned this downtime, check the BEA TOP END system and bring it up if necessary. Also check network connectivity.
1047
WARN: Network connection closed by TOP END
Description
The network connection has been closed for one of the following reasons: the BEA TOP END system was shut down, the NA was shut down, or the network connection was broken.
Action
If you have planned this downtime, no action is required. If you have not planned this downtime, check the BEA TOP END system and bring it up if necessary. Also check network connectivity.
1048
WARN: Network connection closed by TOP END
Description
The network connection has been closed for one of the following reasons: the BEA TOP END system was shut down, the NA was shut down, or the network connection was broken.
Action
If you have planned this downtime, no action is required. If you have not planned this downtime, check the BEA TOP END system and bring it up if necessary. Also check network connectivity.
1049
ERROR: function <val: default from service> too long, max val chars
Description
The BEA TOP END function name defaults to the BEA TUXEDO service name. The number of characters in the BEA TUXEDO service name does not exceed the number allowed for service names, but it does exceed the number of characters allowed for function names.
Action
Adda function name that contains no more than eight characters to the service definition file and re-boot the gateway.
1050
WARN: unable to connect to TOP END system and retry option is disabled. Exiting server...
Description
The -R
parameter was
specified as 0
in the CLOPT
entry for the gateway. The
gateway may restart and attempt to connect again (if it has been configured for restart).
Action
No action is required.
1051
WARN: unsupported command-line option val
Description
The option specified in the CLOPT
line for the gateway is not recognized. The gateway ignores it.
Action
No action is required.
1052
ERROR: call to tgAllocTuxedoBuffer failed
Description
The gateway was unable to allocate the memory needed for BEA TUXEDO communication.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1053
ERROR: call to tgConvertMessage failed TUX2TE incoming
Description
The gateway was unable to convert the BEA TUXEDO client request into the BEA TOP END buffer format.
Action
Check the message in the userlog preceding this message for fur ther information. Possible symptoms are: message too large (max 30K), unsupported BEA TUXEDO buffer type.
1054
ERROR: call to tgConvertMessage failed TUX2TE outgoing
Description
The gateway was unable to convert the BEA TOP END server response into the BEA TUXEDO buffer format.
Action
Check the message in the userlog preceding this message for fur ther information. Possible symptoms are: message too large (max 30K), unsupported BEA TUXEDO buffer type.
1055
ERROR: no service mappings defined in file name
Description
Noentries for the gateway are included in the service definition file. For the GWTE2TUX
gateway, there are no
entries in the TE_LOCAL_SERVICES
section. For the GWTUX2TE
gateway, there are no entries in the TE_REMOTE_SERVICES
section.
Action
Add service entries for the gateway.
1056
INFO: TOP END admin message: name
Description
A BEA TOP END administrative message was sent to the gateway.
Action
No action is required.
1057
WARN: error while processing TOP END admin message [name,name]
Description
A BEA TOP END administrative message was sent to the gateway and an error occurred in the tp_system_admin
() call.
Action
No action is required.
1058
ERROR: tp_server_send failed [name,name], ext_status=[name,name]
Description
The GWTE2TUX
gateway failed
an attempt to send the response to the BEA TOP END client. The gateway will continue to
process messages.
Action
Check the description of the error code available in the tp_server_send
(3T) entry in the BEA TOP END Reference Manual.
![]() |
![]() |
![]() |
![]() |
||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |