e-docs > Tuxedo > Messages > LIBGWT Catalog List > LIBGWT Messages 1200-1299 |
|
LIBGWT Messages 1200-1299
1200
INFO: Transaction received HEURISTIC MIX result from remote domain val
Description
The Domain gateway received a heuristic mix message indicating that part of the transaction committed and part of the transaction rolled back. This may cause an inconsistency in the application data.
Action
No action required.
1201
INFO: Transaction received HEURISTIC HAZARD result from remote domain val
Description
The Domain gateway received a heuristic hazard message indicating that the outcome of part of the transaction is uncertain. This may cause an inconsistency in the application data.
Action
No action required.
1202
ERROR: Bad message from sub. Closing file descriptor
Description
An invalid message was received in the Domain gateway. The gateway connection will be closed.
Action
Ensure that the TYPE values are set correctly if encoding is needed between domains.
1203
ERROR: Memory allocation failure for decompression
Description
An attempt dynamically to allocate memory from the operating system failed while decompressing a received message.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1204
ERROR: Memory allocation failure for decompression
Description
An attempt dynamically to allocate memory from the operating system failed while decompressing a received message.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1205
ERROR: Unable to obtain remote domain entry from shmem
Description
While compressing a message, the entry for the remote domain could not be found (to determine the compression limit).
Action
This error should not occur. Contact BEA Customer Support.
1206
ERROR: Memory allocation failure for compression
Description
An attempt dynamically to allocate memory from the operating system failed while compressing a message.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1207
ERROR: Unable to obtain remote domain entry from shmem
Description
While compressing a message, the entry for the remote domain could not be found (to determine the compression limit).
Action
This error should not occur. Contact BEA Customer Support.
1208
ERROR: Memory allocation failure for compression
Description
An attempt dynamically to allocate memory from the operating system failed while compressing a message.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1209
ERROR: Memory allocation failure for decompression
Description
An attempt dynamically to allocate memory from the operating system failed while decompressing a message.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1210
ERROR: decompression failed
Description
An error occurred while decompressing a message.
Action
Check for other errors in the event log.
1211
ERROR: Failed to destroy inflate structure
Description
An error occurred while decompressing a message.
Action
Check for other errors in the event log.
1214
WARN: Corrupted Communication Control data detected!
Description
An error occurred in the information associated with the domain connection.
Action
Contact BEA Customer Support.
1215
WARN: Communication to remote domain <rdom> already disconnected
Description
A message was sent to a domain that has already disconnected from the local domain.
Action
Re-try the operation.
1218
ERROR: memory allocation failed for compression
Description
The Domain Gateway library software detected an error while trying to compress a message. The process was unable to allocate enough virtual memory for the operation.
Action
Attempt to identify and stop any extraneous processes to free up virtual memory on your system.
See Also
tpstrerror
(3c)
1219
ERROR: compression fails...continuing
Description
The Domain Gateway library software detected an error while trying to compress a message. An internal function call returned a failure.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
See Also
tpstrerror
(3c)
1220
ERROR: memory allocation failure in decompression
Description
The Domain Gateway library software detected an error while trying to decompress a message. The process was unable to allocate enough virtual memory for the operation.
Action
Attempt to identify and stop any extraneous processes to free up virtual memory on your system.
See Also
tpstrerror
(3c)
1221
ERROR: decompression of message failed
Description
The Domain Gateway library software detected an error while trying to decompress a message. An internal function call returned a failure.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
See Also
tpstrerror
(3c)
1224
ERROR: Minimum encryption (number of bits) is larger than 0, but the link level package is not installed
Description
The Domain Gateway library software detected an error while trying to process a connect operation. The minimum number of encryption bits number of bits specified in the DM_TDOMAIN
section of the domain configuration file is greater than zero; however, no link level security package is installed.
Action
Correct the configuration so that the minimum number of encryption bits is consistent with the link level security package in use.
See Also
dmconfig
(5)
1226
ERROR: Could not allocate encryption handle
Description
The Domain Gateway library software detected an error while trying to process a connect operation. The encryption handle could not be allocated. An internal function call returned a failure. A more descriptive error messages will be issued by the failing routine.
Action
Check the surrounding error messages for more descriptive error information.
See Also
tpstrerror
(3c)
1229
ERROR: Encryption negotiation failure
Description
The Domain Gateway library software detected an error while trying to receive a message. An error was detected in the encryption flag settings. The encryption flags are all zero.
Action
Ensure that the encryption bit settings in the DM_TDOMAIN
sections of the dmconfig
file are consistent for communicating domains.
See Also
dmconfig
(5)
1230
ERROR: Unable to generate first diffie-hellman packet
Description
The Domain Gateway library software detected an error while trying to send a message. An internal function call for encryption returned a failure. Additional error messages from the failing routine will be issued prior to this message.
Action
Check the messages from the failing routine for more specific information regarding the cause of this error.
See Also
tpstrerror
(3c)
1231
ERROR: Could not allocate encryption handle
Description
The Domain Gateway library software detected an error while trying to receive a message. An error was detected in the internal routine to allocate an encryption handle. A more specific message will be issued by the failing routine.
Action
Check the surrounding error messages for additional information.
See Also
tpstrerror
(3c)
1232
ERROR: Memory allocation error
Description
The Domain Gateway library software detected an error while trying to receive a message. The process was unable to allocate enough virtual memory for the operation.
Action
Attempt to identify and stop any extraneous processes to free up virtual memory on your system.
See Also
tpstrerror
(3c)
1233
ERROR: Unable to generate second diffie-hellman packet
Description
The Domain Gateway library software detected an error while trying to send a message. An internal function call for encryption returned a failure. Additional error messages from the failing routine will be issued prior to this message.
Action
Check the messages from the failing routine for more specific information regarding the cause of this error.
See Also
tpstrerror
(3c)
1234
ERROR: Unexpected link level encryption failure
Description
The Domain Gateway library software detected an error while trying to send a message. An internal function call for encryption returned a failure.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
See Also
tpstrerror
(3c)
1236
ERROR: Encryption negotiation failure
Description
The Domain Gateway library software detected an error while trying to receive a message. An error was detected in the encryption flag settings. The encryption flags are all zero.
Action
Ensure that the encryption bit settings in the DM_TDOMAIN
sections of the dmconfig
file are consistent for communicating domains.
See Also
dmconfig
(5)
1237
ERROR: Invalid security level
Description
The Domain Gateway library software detected an error while trying to receive a message. An invalid encryption level was detected.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
See Also
tpstrerror
(3c)
1238
ERROR: Unexpected link level encryption failure
Description
The Domain Gateway library software detected an error while trying to receive a message. An internal function call for encryption returned a failure.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
See Also
tpstrerror
(3c)
1240
ERROR: Minimum encryption (number of bits) is larger than 0, but the link level package is not installed
Description
The Domain Gateway library software detected an error while trying to process a receive operation. The minimum number of encryption bits number of bits specified in the DM_TDOMAIN
section of the domain configuration file is greater than zero; however, no link level security package is installed.
Action
Correct the configuration so that the minimum number of encryption bits is consistent with the link level security package in use.
See Also
dmconfig
(5)
1241
ERROR: Invalid parameter, tdom_link is NULL
Description
GWTDOMAIN detects an internal error, or possible data corruption when it does a network open call.
Action
Contact your BEA Customer Support.
1242
ERROR: Invalid parameter, tdom_link contains NULL pointer
Description
GWTDOMAIN detects an internal error, or possible data corruption when it does a network open call.
Action
Contact your BEA Customer Support.
1243
WARN: Open domain_name address ip_port failed, Network error(0xerror_code)
Description
GWTDOMAIN
tries to open a listening end point form domain domain_name using the port number and IP address as specified by ip_address failed with network error code specified. This can be caused by either the port is already been used, or the port just been release in some TCP/IP implementation.
Action
If the configuration contains multiple address entries for the specified domain, the GWTDOMAIN
will continue with the next one. If all the address specified exhausted and still can't open the listening end point, GWTDOMAIN
will exit. The user can try to restart it, or change configuration and restart it.
1244
WARN: No more NW address to try
Description
GWTDOMAIN
already tries all the listening end points specified in the BDMCONFIG
file, and still could not able to open any listening end point.
Action
The administrator should check whether the configuration is correct, and whether any other process already uses the port number.
1245
INFO: Try next one, device device_name address ip_address
Description
This is informational. It tells the user that GWTDOMAIN
is going to try the next IP address and port number specified in the configuration.
Action
Nothing.
1246
ERROR: Invalid parameter, tdom_link is NULL
Description
GWTDOMAIN
detects an internal error, or possible data corruption when it does a network connect call.
Action
Contact your BEA Customer Support.
1247
ERROR: Invalid parameter, tdom_link contains NULL pointer
Description
GWTDOMAIN
detects an internal error, or possible data corruption when it does a network connect call.
Action
Contact your BEA Customer Support.
1249
WARN: Connect to domain_name address ip_addr failed, Network error(0xerrno)
Description
GWTDOMAIN
tries to connect to a remote domain domain_name using the port number and IP address as specified by ip_address failed with network error code specified. This can be caused by network failure, wrong IP address or port number in the configuration, or the remote GWTDOMAIN
not yet up and running, or the remote GWTDOMAIN
has not yet able to open the listening end, or the remote GWTDOMAIN
opened different end point then what specified in the local domain configuration file.
Action
Check the network, and check proper configuration. And also make sure the remote domain GWTDOMAIN
is up and running and use the port and IP address specified in the configuration.
1252
ERROR: Unable to obtain transaction entry from shared memory (rollback)
Description
The /Domain transaction table entry for this transaction was not found in the /Domain shared memory tables when trying to process a transaction rollback. This could be caused if a stray message was received for a transaction that was already aborted.
Action
If the dmadmin
subcommand pt
indicates that the transaction has already been removed from the /Domain shared memory, no action is required. Otherwise, contact your BEA Customer Support.
1254
ERROR: Unable to determine locality of transaction
Description
The GWTDOMAIN
process was unable to determine the locality (local or remote) of a transaction. This is an internal processing error.
Action
This is an internal error with no associated user action.
See Also
tperrno
(5)
1256
WARN: Unable to create local txid in shared memory for transaction recovery
Description
The GWTDOMAIN
process was unable to recover a transaction because the transaction table is full. The transaction will be rolled back.
Action
Modify the configuration to allow for more concurrent transactions.
1257
ERROR: Unable to decrypt message
Description
The gateway is unable to decrypt a message sent from a remote domain. The message was encrypted using Link Level Encryption.
Action
Check the remote domain ULOG to see if the message is being properly encrypted by the gateway process.
1258
ERROR: Unable to process buffers
Description
The Domain Gateway library software detected an error while trying to receive a message. An internal function call for encryption returned a failure.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
See Also
tpstrerror
(3c)
1259
ERROR: Memory allocation failure for encryption
Description
An attempt to dynamically allocate memory from the operating system failed while attempting to create an encrypted message.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1260
ERROR: Memory allocation error
Description
An attempt to dynamically allocate memory from the operating system failed. This is occurring in the routine where the software is attempting to open the gateway's listening endpoint.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1261
ERROR: Can not allocate network descriptor
Description
An attempt to dynamically allocate memory from the operating system failed. This is occurring in the routine where the software is attempting to open a connection to a remote gateway.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1265
WARN: Unable to create local txid in shared memory for transaction recovery
Description
The GWTDOMAIN
process was unable to recover a transaction because the transaction table is full. The transaction will be rolled back.
Action
Modify the configuration to allow for more concurrent transactions.
1267
ERROR: Unable to convert old style network buffer. Error code val
Description
The gateway received a message from a remote gateway running on a older TUXEDO release. In attempting to convert the message to the newer protocol, an error was encountered.
Action
Check that the message is being sent by a valid domain gateway process.
1268
ERROR: Unable to switch to new protocol
Description
During the initial protocol exchange between gateways, the gateway attempts to set the protocol level of the remote gateway and an error is encountered.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
1269
ERROR: Unable to switch to new protocol
Description
During the initial protocol exchange between gateways, the gateway attempts to set the protocol level of the remote gateway and an error is encountered.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
1270
ERROR: connections structure initialization failure
Description
An attempt to dynamically allocate memory from the operating system failed. This is occurring in the gateway's network initialization routine.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
1271
ERROR: Unable to initialize encryption key
Description
The gateway is encountering an error initializing the APP_PW
encryption key during the initial protocol exchange.
Action
Check the preceding ULOG message(s) for information on why the APP_PW
encryption calls are failing.
1272
ERROR: Unable to encrypt challenge value
Description
The gateway, when attemping to encrypt the APP_PW
challenge value during initial protocol exchange, is encountering an error.
Action
Check the preceding ULOG message(s) for information on why the APP_PW
encryption calls are failing.
1273
ERROR: Unable to initialize encryption key
Description
The gateway, when attempting to initialize the encryption key during initial protocol exchange when security is DM_PW
, is encountering an error.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
1274
ERROR: Unable to encrypt challenge value
Description
The gateway, when attempting to encrypt the challenge value during initial protocol exchange for DM_PW
security, is failing.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
1275
ERROR: Failed to convert buffer
Description
The gateway is failing to convert an outbound TMS message to an older protocol version. The gateway is communicating with a remote gateway that does not support the newer protocol version and therefore needs to convert to an older protocol.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
1276
ERROR: Unable to presend transaction buffer
Description
The gateway is failing to convert an outbound message to an older protocol version. The gateway is communicating with a remote gateway that does not support the newer protocol version and therefore needs to convert to an older protocol.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
1278
ERROR: Could not allocate a message
Description
An attempt to dynamically allocate memory from the operating system failed. This is occurring in the gateway's mesage send routine.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1279
ERROR: Could not allocate a domain header
Description
An attempt to dynamically allocate memory from the operating system failed. This is occurring in the gateway's mesage send routine, while trying to add the domains header.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1280
ERROR: Could not allocate a domain header
Description
An attempt to dynamically allocate memory from the operating system failed. This is occurring in the gateway's mesage send routine, while trying to add the domains security header.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1281
ERROR: Failed to convert buffer
Description
The gateway is failing to convert an outbound buffer to an older protocol version. The gateway is communicating with a remote gateway that does not support the newer protocol version and therefore needs to convert to an older protocol.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
1282
ERROR: Memory allocation failure for compression
Description
An attempt dynamically to allocate memory from the operating system failed while compressing a message.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1283
ERROR: Could not encode header
Description
The gateway is unable to encode the meta-header of an outbound message.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
1284
ERROR: Unable to find domains header
Description
The gateway is failing to convert an outbound buffer to an older protocol version, because the buffer does not contain the domains header.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
1285
ERROR: Unable to find security header
Description
The gateway is failing to convert an outbound buffer to an older protocol version, because the buffer does not contain the domains security header and security is turned on.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
1286
ERROR: Error converting message to old style. Error code val
Description
The gateway is failing to convert an outbound message to an older protocol version. The gateway is communicating with a remote gateway that does not support the newer protocol version and therefore needs to convert to an older protocol.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
1287
ERROR: Unable to find domains header
Description
The gateway received a message from a remote gateway with no domains header.
Action
Check the remote domain ULOG for further diagnosis.
1288
ERROR: Bad message from val. Closing file descriptor
Description
The gateway received an incorrectly formatted message from a remote gateway.
Action
Check the remote domain ULOG for further diagnosis.
1289
ERROR: Unable to remove domains header
Description
An internal error occurred while attempting to remove domain information from a message.
Action
Contact BEA Customer Support.
See Also
GWTDOMAIN
1290
ERROR: Unable to remove domains header
Description
The gateway is unable to strip the domains header from the message. The header must be stripped by the gateway before forwarding the message to a TUXEDO server.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
1291
ERROR: Invalid input buffer
Description
The gateway is unable to locate the TUXEDO header in an outbound message.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
1292
ERROR: Memory allocation error
Description
An attempt dynamically to allocate memory from the operating system failed while preparing to send a message.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1293
ERROR: Invalid message format
Description
The GWTDOMAIN
was unable to add a header extension to an
internal message.
Action
Contact BEA Customer Support.
See Also
GWTDOMAIN
1294
ERROR: Invalid message format
Description
The gateway detected that the format of the oubound message is invalid. This was discovered while trying to add header information.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
1295
ERROR: Unable to intialize administration key for domain val
Description
The gateway is encountering an error initializing the APP_PW
encryption key during the initial protocol exchange.
Action
Check the preceding ULOG message(s) for information on why the APP_PW
encryption calls are failing.
1296
ERROR: Unable to intialize administration key for domain val
Description
The gateway is encountering an error initializing the DM_PW
encryption key during the initial protocol exchange.
Action
Check the preceding ULOG message(s) for information on why the DM_PW
encryption calls are failing.
1297
ERROR: Unable to decrypt challange from val
Description
The gateway, when attempting to decrypt the challenge value during initial protocol exchange for APP_PW
security, is failing.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
1298
ERROR: Unable to decrypt challange from val
Description
The gateway, when attempting to decrypt the challenge value during initial protocol exchange for DM_PW
security, is failing.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
1299
ERROR: Unable to intialize administration key for domain val
Description
The gateway is encountering an error initializing the APP_PW
encryption key during the initial protocol exchange.
Action
This is an internal error with no associated user action. If the error persists, contact your BEA Customer Support with the exact error message.
![]() |
![]() |
![]() |
![]() |
||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |