e-docs > Tuxedo > Messages > GP Catalog List > GP Messages 1100-1199 |
|
GP Messages 1100-1199
1100
ERROR: TUXDIR environment variable not set
Description
While trying to read the $TUXDIR/udataobj/RM file to include a resource manager into a client or server, the TUXDIR environment variable was not set.
Action
Set and export the TUXDIR environment variable and re-run the operation.
See Also
BEA TUXEDO Administrator's Guide
1101
ERROR: Cannot open file filename
Description
The program was unable to read the RM file in $TUXDIR/udataobj/RM.
Action
Ensure that the TUXDIR environment variable is set correctly and that the user has read permission on the RM file.
See Also
BEA TUXEDO Administrator's Guide
1102
ERROR: Cannot find RM rmname in file filename
Description
While searching $TUXDIR/udataobj/RM, an entry for the specified RM, rmname, could not be found.
Action
Make sure that the correct RM name is specified and an entry exists for it in $TUXDIR/udataobj/RM. Contact your BEA TUXEDO System Technical Support.
See Also
BEA TUXEDO Administrator's Guide
1103
ERROR: Can't allocate space for _gp_pgHand struct
Description
An attempt dynamically to allocate memory from the operating system using malloc()
failed while setting up for pagination from one of the command interpreters on the Netware platform, the standard output could not be re-set. The message prints additional information regarding why the operation failed.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1104
ERROR: Can't create temporary paging file, error_info
Description
While setting up for pagination from one of the command interpreters on the Netware platform, a temporary file could not be created. The message prints additional information regarding why the operation failed.
Action
Check the additional information printed. The problem may be related to security, permissions, file system space, etc. Contact your BEA TUXEDO system Technical Support.
1105
ERROR: Can't open temporary paging file filename for writing, error_info
Description
While setting up for pagination from one of the command interpreters on the Netware platform, a temporary file could not be opened for writing. The message prints additional information regarding why the operation failed.
Action
Check the additional information printed. The problem may be related to security, permissions, file system space, etc. Contact your BEA TUXEDO system Technical Support.
1106
ERROR: Can't reopen temporary paging file filename as stdout, error_info
Description
While setting up for pagination from one of the command interpreters on the Netware platform, an I/O error occurred. The message prints additional information regarding why the operation failed.
Action
Check the additional information printed. The problem may be related to security, permissions, file system space, etc. Contact your BEA TUXEDO system Technical Support.
1107
ERROR: Can't open temporary paging file filename for reading, error_info
Description
While setting up for pagination from one of the command interpreters on the Netware platform, a temporary file could not be opened for writing. The message prints additional information regarding why the operation failed.
Action
Check the additional information printed. The problem may be related to security, permissions, file system space, etc. Contact your BEA TUXEDO system Technical Support.
1108
ERROR: Can't get status of temporary paging file filename, error_info
Description
While setting up for pagination from one of the command interpreters on the Netware platform, a temporary file could not be accessed. The message prints additional information regarding why the operation failed.
Action
Check the additional information printed. The problem may be related to security, permissions, file system space, etc. Contact your BEA TUXEDO system Technical Support.
1109
ERROR: Can't allocate num bytes for paging
Description
An attempt dynamically to allocate memory from the operating system using malloc()
failed while setting up for pagination from one of the command interpreters on the Netware platform.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1110
ERROR: Error in processing temporary paging file filename
Description
While setting up for pagination from one of the command interpreters on the Netware platform, a temporary file could not be read correctly.
Action
Contact your BEA TUXEDO system Technical Support.
1111
ERROR: Can't reallocate num bytes for paging
Description
An attempt dynamically to allocate memory from the operating system using realloc() failed while setting up for pagination from one of the command interpreters on the Netware platform.
Action
Make sure the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
1112
ERROR: AllocateResourceTag failed
Description
While finishing up pagination from one of the command interpreters on the Netware platform, AllocateResourceTag failed for the NLM.
Action
Contact your BEA TUXEDO system Technical Support.
1113
ERROR: Invalid current screen, error_info
Description
While finishing up pagination from one of the command interpreters on the Netware platform, the current screen information could not be retrieved. The message prints additional information regarding why the operation failed.
Action
Check the additional information printed. Contact your BEA TUXEDO system Technical Support.
1114
ERROR: NWSInitializeNut failed
Description
While finishing up pagination from one of the command interpreters on the Netware platform, NWSInitializeNut failed for the NLM.
Action
Contact your BEA TUXEDO system Technical Support.
1115
ERROR: Can't reopen stdout, error_info
Description
While finishing up pagination from one of the command interpreters on the Netware platform, the standard output could not be re-set. The message prints additional information regarding why the operation failed.
Action
Check the additional information printed. Contact your BEA TUXEDO system Technical Support.
1116
ERROR: Can't open socket.
Description
While establishing a network connection using the socket service provider, the open failed on the socket.
Action
Check that the network is configured correctly and that sufficient resources are allocated.
![]() |
![]() |
![]() |
![]() |
||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |